- Home
- >
- Tender
- >
- Goa Tender
- >
- Department of Power And Electricity Department
- >
NTID 44282987
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowWork Of Design Supply Erecti in Goa - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Work Of Design Supply Erecti" in Goa, India.
- Opening Date : Tue 10th March, 2026
- Closing Date : Mon 9th March, 2026
- ₹ 87296967.00
- NTID 44282987
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
1745939.00 -
Document Cost
1500.00 -
Estimated Cost
87296967.00
BOQ Items Total Items : 79 | Total Qty : 23126.28
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Supply | ||
| 2 | Supply of Indoor Control & Protection Panel for 110KV Line Bay: Supply of Control and Protection Panel for 110KV line bay- panel consisting of Simplex swing frame Panel with front glass door having PRP compliant Numerical Protection Relay(Main-I) having Protection Functions of Distance, switch onto fault, A/R,PSB, Directional & non directional overcurrent and earth fault, LBB, over/under voltage, frequency and synch. Numerical Protection Relay (Main-II) of different make having Protection Functions of Distance, switch onto fault, A/R, PSB, Directional & non directional overcurrent and earth fault, LBB, over/under voltage, frequency and synch. with 1 No of Numerical Bay Control Unit along with necessary auxiliary relays for AC/DC Supply Supervision, DC changer over, Breaker contro switch, A/R selection switch and carrier selectio switch and required FO cables, Station & Process bus level ethernet switch line interface Unit to make PRP network at both Station and process bus level. All numerical relays shall be TEC 61850-9-2LE/IEC 61850 Ed2 or IEC 61850Ed2.1 protocol compliant for sampled values streaming, At the process bus level, the PRP protocol according to the IEC 62439-3/4 shall be used, Loss of GPS input to protection system shall not result in blocking of protection functions. (Preferred Make: Siemens, ABB/Hitachi GE) | 6.00 | Nos. |
| 3 | Supply of Outdoor Process Bus Interface Panel of line Bay: Supply of Outdoor Process Bus Intertace panel for 220KV line bay consisting Simplex Panel with canopy having PRP compliant 2 nos. of Switchgear control cum merging Unit (with min. 8 CT, 8 VT, 41DI & 28DO) along with necessary FO cables, Line Interface Unit, test blocks, voltage selection relays, AC Static Tri-vector Energy Meter with DLMS compliance, Media Converter (RS485 to Fiber Optic) for Energy Meter, Auxiliary Relay for AC/DC Supervision and DC change over relay, outdoor pregerminated military grade 6core MM 50/125 um or 62/125 um glass fiber core armoured cable with HDPE pipe as required, IEC 61850 Standard Ed.2. The outdoor panel shall be made of CRCA with 3mm thick sheets for load bearing and 2mm for non-load bearing sides with minimum IP-65 and all required accessories.(Preferred Make: Siemens, ABB/Hitachi, GE) | 6.00 | Nos. |
| 4 | SETC of Switchgear Control cum Merging Unit ( with min 8 CT, 8VT, 41 DI & 28 DO) along with necessary FO Cables | 1.00 | Nos. |
| 5 | SETC of Numerical Distance Protection Main I having protection functions of distance, switch onto fault, A/R, PSB, Directional & Non Directional O/C & E/F, LBB, Over/Under Voltage, Frequency & Sync | 1.00 | Nos. |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054