- Home
- >
- Tender
- >
- Madhya Pradesh Tender
- >
- Department of Navalsingh Sahakari Shakkar Karkhana Maryadit
- >
NTID 44869219
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowW p 21kg cm2 Cap - 20 T hr in East Nimar - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "W p 21kg cm2 Cap - 20 T hr " in East Nimar, India.
Navalsingh Sahakari Shakkar Karkhana Maryadit
East Nimar, Madhya Pradesh, India
NTID 44869219
- Opening Date : Wed 29th April, 2026
- Closing Date : Tue 28th April, 2026
- ₹ 0.00
- NTID 44869219
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
25000.00 -
Document Cost
590.00 -
Estimated Cost
Refer Documents
BOQ Items Total Items : 7 | Total Qty : 417
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Description and material grade | ||
| 2 | 40 Ton Boiler No. MP-4637 - Bank Tubes (Drum to Drum) Riser Tube Row No.7, Row No.8 & Row No.9. Down comer Tube Row No. Row No.7, Row No.8 & Row No.9. MAT B.S. 3059 PART 2 Gr.440 H.F.S. as per our Drawing No. NSSK/BR-348 Size- OD 50.8 mm x 4.06 mm Thk. a. Replace coils to be hanged on hangers properly so that coils load be distributed on hangers. b. At top and bottom portion of coils necessary arrangements with S.S. flat iron (50mm x 10mm) to be made such that coils does not collide and remain in one line. (Make of Tube TATA/JINDAL/INDIAN SEAMLESS/TI) | 354.000 | Nos. of Tubes (59x6) |
| 3 | 20 MT Boiler No. MP-3562- Replacement of RHS & LHS side bottom header complete with flange and dummy with stub nipple, as per SA106 Grade B, as per our Drawing No. NSSK/B-307 Size of Header OD 219 mm x 4633 mm Lg. x 12.7 mm Thk. (Make TATA/JINDAL/INDIAN SEAMLESS/TI) | 2.000 | No fo Headers |
| 4 | 20 MT Boiler No. MP-3562- Replacement of RHS & LHS side bottom header stubs as per our Drawing No. NSSK/B-307 a) Size of Stub OD 70 mm x 83 mm Lg. x 9 Gauge | 16.000 | No of Stubs |
| 5 | b) Size of Stub OD 76.2 mm x 83 mm Lg. x 9 Gauge | 6.000 | No of Stubs |