- Home
- >
- Tender
- >
- Telangana Tender
- >
- Department of INDIAN INSTITUTE OF TECHNOLOGY
- >
NTID 45976510
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowSupply Installation Testing in SANGAREDDY - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Supply Installation Testing " in SANGAREDDY, India.
INDIAN INSTITUTE OF TECHNOLOGY
SANGAREDDY, Telangana, India
NTID 45976510
- Opening Date : Tue 11th August, 2026
- Closing Date : Mon 10th August, 2026
- ₹ 18333818.00
- NTID 45976510
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
366680.00 -
Document Cost
Refer Documents -
Estimated Cost
18333818.00
BOQ Items Total Items : 21 | Total Qty : 2606
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Supply, Installation, Testing & Commissioning of 18.5KW Heating capacity, air sourced heat pump with hot water Production capacity minimum 400 LPH, COP 4.4, suitable for 415V, 3 Phase, 50Hz power supply, producing hot water maximum upto 600C, with ambient Operating range -70C to 430C and protection grade of IPX4, noise level <60 dB(A), Circulating water flow rate 4 m3/h, Compressor capacity 5HP, wired digital remote control complete with all integral components as per manufacturer's standard specifications and suitable MS painted stand for heatpump as required to the existing Solar Water Heating System including all accessories, manpower/machinary and as per the directions of Engineer-In-Charge. | 22 | Each |
| 2 | Supply, Installation, Testing & Commissioning of 12KW heating capacity air sourced heatpump with minimum 250 LPH hot water production capacity COP 4.07, suitable for 220V, 1 Phase, 50HZ power supply, producing hot water maximum upto 600C, with ambient Operating range -70C to 430C and minimum IPX4 protection, noise level <55 dB(A), Compressure capacity 4HP, Circulating water flow rate 4 m3/h, complete with all integral components including circulation pump, wired digital remote control as per manufacturer's standard specifications and suitable MS painted stand for heatpump as required to the existing Solar Water Heating System including all accessories, manpower/machinary and as per the directions of Engineer-In-Charge. | 4 | Each |
| 3 | Providing and fixing internal plumbing interconnection in the Solar Water Heating System(between the Solar Plates and Tank) and also between heat pump and hot water storage tank using pre-insulated multilayer composite pipe of 32mm suitable for hot water lines, complete with all required fittings, valves, elbows, tees, unions, clamps, insulation and other accessories as required, the work is inclusive of all crimping and associated fittings required for the interconnections with all required manpower/T&P and as per the directions of Engineer-In-Charge. Pre-Insulated Composite Pipe: The inner PE-AL-PE or PE-AL-PEX Composite pipe | 780 | Mtrs |
| 4 | Supply, handling, shifting, placing and installation of 1500 litre capacity cylindrical Stainless Steel (SS) hot water storage tank, fabricated out of SS-316L Low corbon steel with minimum plate thickness of 6mm, suitable for continuous working temperature up to 95 120 C, Pressure withstand of minimum 10Bar for Solar Water Heating System, including thermal insulation with minimum 50 mm thick PUF insulation and aluminium sheet cladding, complete with inlet, outlet, vent pipe, drain, Analog thermometers on tank at bottom and top level, provision for backup immersion heater and thermocouple for input to digital temperature controller, suitable painted PU structural steel-stand for mounting the tank, including required manpower, all accessories and shifting of old tanks to the shown location as per the directions of Engineer-In-Charge, etc. as required. | 4 | Each |
| 5 | Supply, handling, shifting, placing and installation of 2500 litre capacity cylindrical Stainless Steel (SS) hot water storage tank, fabricated out of SS-316L Low corbon steel with minimum plate thickness of 6mm, suitable for continuous working temperature up to 95 120 C, Pressure withstand of minimum 10Bar for Solar Water Heating System, including thermal insulation with minimum 50 mm thick PUF insulation and aluminium sheet cladding, complete with inlet, outlet, vent pipe, drain, Analog thermometers on tank at bottom and top level, provision for backup immersion heater and thermocouple for input to digital temperature controller, suitable painted PU structural steel-stand for mounting the tank, including required manpower, all accessories and shifting of old tanks to the shown location as per the directions of Engineer-In-Charge, etc. as required. | 22 | Each |