- Home
- >
- Tender
- >
- Haryana Tender
- >
- Department of Food Corporation Of India
- >
NTID 39912098
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowSupply Installation Testing in Kurukshetra - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Supply Installation Testing " in Kurukshetra, India.
Food Corporation Of India
Kurukshetra, Haryana, India
NTID 39912098
- Opening Date : Wed 16th April, 2025
- Closing Date : Tue 15th April, 2025
- ₹ 945740.00
- NTID 39912098
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
19000.00 -
Document Cost
Refer Documents -
Estimated Cost
945740.00
BOQ Items Total Items : 38 | Total Qty : 379.43
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Fabricating and supplying Silent Type' CPCB IV+ norms compliant Diesel Generating set alongwith Prime Power Rating of specified kVA as mentioned below depot wise, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system and consisting of the followings as per OEM standards (a) Diesel Engine: CPCB IV+ compliant Diesel engine with 4 cylinder, 4 stroke water cooled , electric start, of minimum specified BHP as mentioned below depot wise at 100% Load factor at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL and conforming to BS 5514, BS 649, IS 10000 (with latest ammendments), capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories with charging alternator and battery charger. (b) Engine mounted Instrument Panel fitted with and having digital display for following: (i) Start-stop switch with key (ii) Water temperature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication (vi) RPM indication (vii) Over speed indication (viii) Low lubricant Oil trip indication (ix) Engine Hours indication (c) Alternator : Synchronous alternator rated at specified kVA as mentioned below depot wise, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR conforming to IS: 4722/BS 2613 (with latest ammendments) for tropical conditions and with class-H insulation. (d) Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with suitable amount of reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. (e) Fuel Tank: Daily service fuel tank capable of giving minimum continuous run of 8 hours, fabricated out of minimum 2 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C pipes of suitable dia. Complete with valves, level indications & accessories as required as per CPWD specifications/OEM standards (f) Exhaust System: Dry exhaust manifold with exhaust silencer and Diesel Oxidation Catalyst. (g) Starting System: 12V DC starting system comprising of starter motors, voltage regulator and arrangement for initial excitation complete with suitable AH capacity battery (lead acid type) as required as per OEM standards. (h) Accoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per CPWD specifications/OEM standards | ||
| 2 | Prime Power rating 25 kVA, 36 BHP Diesel Engine, 25 kVA Alternator at FSD Kurukshetra | 1.00 | Set |
| 3 | Fabricating and supplying automatic mains failure control including auto by-pass panel, suitable for specified kVA as mentioned below depot wise silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, kWh, kVARh & provision for overload, short Circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all complete and inter locking including the following as per OEM standards: (a) 2 Nos. of specified Amp. 3 pole MCB/MCCB as mentioned below depot wise (b) Auto/Manual/Off selector switch (c) 2 Nos. over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay (d) 3 Sets of current transformers 15 P 10 accuracy protection and 15 VA class-I for metering (e) Energy analyser unit to indicate current voltage frequency power factor and kWh (I) Indicating lamps for load On mains and load on set (g) Fuse for instruments (h) Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment. (i) Main supply failure monitor (j) Supply failure timer (k) Restoration timer (I) Control unit with three impulse automatic engine start/stop and failure to start lockout. (m) Impulse counter with locking and reset facility. (n) ON/OFF/Control circuit switch with indicator (o) Audio/Video annunciation for (i) High water temperature (ii) Low lubricating oil pressure (iii) Engine over speed (iv) Engine fails to start (v) Full load/maximum load warning | ||
| 4 | Prime Power rating 25 kVA, 50 A MCB at FSD Kurukshetra | 1.00 | Set |
| 5 | Construction of cement concrete floor / foundation PCC (1:2:4, M-20 grade) foundation of weight 2.5 times the operating weight of the Genset with enclosure or as recommended by the Genset manufacturer OEM/OEA, whichever is higher. The foundation should be min 300 mm high from the ground level. The length and breath of foundation should be at least 250mm more on all sides than the size of the enclosure comprising of following: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 fine sand derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) as sub-base foundation. |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054