Inquiry NowSupply Installation Commissi in Parganas - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Supply Installation Commissi" in Parganas, India.
RAMAKRISHNA MISSION VIVEKANANDA CENTENARY COLLEGE
Parganas, West Bengal, India
NTID 46463479
- Opening Date : Thu 17th September, 2026
- Closing Date : Tue 15th September, 2026
- ₹ 0.00
- NTID 46463479
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
34000.00 -
Document Cost
Refer Documents -
Estimated Cost
Refer Documents
BOQ Items Total Items : 10 | Total Qty : 10
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Laboratory Equipment | ||
| 2 | Fourier Transformed Infrared Spectroscopy- Attenuated Total Reflectance (ATR-FTIR) (1Ps.) Technical Specifications Optical System The spectrometer should be able to record the spectrum of a sample in the wave number region of 7900 - 350 cm-1. The system should be sealed and desiccated. Rechargeable desiccant cartridges with humidity indicator. Continuous electronic monitoring of multiple spectrometer components with temperature and humidity sensors. Spectrometer must provide a 10 years warranty on the interferometer, laser, and source. Desiccant, power supply, sample compartment windows, infrared source must be user replaceable without opening the cover. Interferometer Interferometer must be a with dynamic alignment to provide high spectral resolution and compensate for tilt, shear, temperature effects, and vibrations that alter line shapes and negatively impact spectral results. Spectral Resolution 0.6 cm-1 spectral resolution or better Signal to Noise Ratio better than 35,000:1 (peak-to-peak, one minute) Wave Number Precision better than 0.001 cm-1 at 2,000 cm-1 Wave number accuracy better than 0.05 cm-1 at 2,000 cm-1 Ordinate Linearity <0.15 %T Detector Deuterated Triglycine Sulfate (DTGS) Detector Source Spectrometer must have a non-migrating hotspot single-point source with a 10-year warranty. Laser Solid-state, temperature-controlled diode laser with long lifetime with a 10-year warranty Smart Background collection (background collected while instrument is idle) Instrument calibration/ performance verification The system must be provided with Internal NIST-traceable 1.5 mil polystyrene film (serialized). Accessories Spectrometer must accept a wide variety of third-party accessories to maximize flexibility and minimize future upgrade costs. Transmission analysis Transmission accessory must be quoted for liquid sample analysis from OEM. ATR ATR accessary should include Diamond ATR crystal with optical base. Both Diamond ATR crystal and optical base must be provided with at least 5 years of warranty. Software Instrument should have Mechanism to automatic atmospheric suppression to remove moisture and CO2 interferences. Advanced data processing options like baseline correction, peak area, peak height measurements, smoothing, spectral comparison etc. must be available. Software should have tools for Quantification method development using Beers’ law, PLS, CLS etc Additional Software should be provided for multi-component search of mixture samples and should have IR interpretation tools. Software must have the ability to automatically create a workflow based on the processing history of a spectrum. Library FTIR spectral libraries must be available with at least 5000 or more spectra. Other requirement Branded Desktop PC & Printer, Suitable Online One KVa UPS for FTIR system. Warranty The complete system should be covered with one year of warranty Special warranty: - • 10 years on Laser, Source & Interferometer • 5 years on complete diamond ATR including diamond cystal. | 1 | Nos |
| 3 | Water Maker Type I (1Ps.) Technical specification: Integrated lab water system that will deliver type 2 and type 1 from a single unit. Feed water specifications: TDS <500ppm Product water Type II : > 10MΩ Type I : 18.2 MΩ Type I TOC <5ppb Flow Rate Type II : 10 liters per hour Type I : 1 -1.5 liters per minute Type II water Storage Capacity: >25 liters Shape: Conical Bottom Vent filter to avoid atmospheric contamination Should have in built UV sanitization module fixed in the tank Auto cutoff once the tank is filled Provision to collect type II water from the tank Easy single touch Type I water dispensing Convenient user interface with minimum display and alarm indication like product water resistivity, low feed water alarm and power on indication Purification steps should involve Depth filter to remove particulate Activated carbon to remove chlorine and organic Reverse osmosis membrane Dual wave length UV to reduce TOC Deionization purification pack to produce ultra-pure water Ultra filtration for Dnase Rnase free water 0.2-micron filter at the point of use to have particulate and bacteria free ultra-pure water dispensing Use of electrostatic sanitization (ESS/EPS) to avoid chemical sanitization of RO membrane Warranty: 24 Months | 1 | Nos |
| 4 | Semi-dry Electrophoretic transfer and power supply (1Ps.) Technical Specifications: Fast blotting system with four gel simultaneously, 2 different cassettes same protocol at different time in 3 mins. System should be open for traditional blotting consumables System should have inbuilt fix electrodes Input power: 100–240 VAC, 276 VA, 50–60 Hz, 175 W max USB port: Yes, input only, for firmware updates System should have Cooling fan Should have inbuilt Power supply with high current of 2.5 A User Interface 18 button keypad, 128 x 64 pixel monochrome display Programmable methods: Up to 25 user-defined Preprogrammed methods: Standard SD, 1.5 mm gels, High MW, Low MW, Mixed MW, Audible alarm: Yes User notifications should have following features: • Power fail during run • No-load detection • No cassette detection • End of run | 1 | Nos |
| 5 | Optical DO Meter- Portable (1Ps.) Technical Specifications: Dissolved Oxygen Measurement Type Optical – luminescence Dissolved Oxygen Range 0.00 to 50.00 mg/L (ppm); 0.0 to 500.0% saturation Dissolved Oxygen Resolution 0.01 mg/L (ppm); 0.1% saturation Dissolved Oxygen Accuracy 1.5% of reading ± 0.01mg/L for 0.00-20.00mg/L , 5% of reading for 20.00-50.00mg/L , 1.5% of reading ±0.1% for 00-200.0%, 5% of reading for 200.0-500.0% Dissolved Oxygen Calibration one or two points automatic calibration at 100% (8.26 mg/L) and 0% (0 mg/L); Single point manual using a value entered by the user in % saturation or mg/L. Dissolved Oxygen Temperature Compensation automatic from -5.0 to 50.0 °C (23.0 to 122.0 °F) Barometric Pressure Compensation automatic from 420 to 850 mmHg Salinity Compensation automatic from 0 to 70 g/L (manually set) Temperature Range -5.0 to 50.0 °C (23 to 122 °F) Temperature Resolution 0.1 °C (0.1 °F) Temperature Accuracy ±0.3 °C (±0.4 °F) Temperature Calibration Single point anywhere within temperature range Temperature Compensation Automatic DO Probe optical DO probe with protective sleeve, internal temperature sensor, quick connect DIN connector and 4m (13’) cable (included) Logging Type On demand with 4000 records capability Connectivity USB-C Automatic Shut-Off User selectable: 5, 10, 30, 60 minutes or disabled GLP Yes- includes last 5 calibrations Calibration Timeout Reminder Yes- user selectable “Calibration due” warning Autoend Yes BOD/OUR/SOUR Yes Display LCD (back lighted display) Battery Type/Life 1.5V AA batteries (4 pcs.) / approx. 200 hours of continuous use without backlight (50 hours with backlight) IP Protection IP67 Environment 0 to 50 °C (32 to 122 °F) max. RH 100% Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”) Weight 450 g (15.9 oz.) with batteries Include DO meter is supplied with optical DO probe, smartcap with RFID, bicomponent zero oxygen solution, 100 mL plastic beakers (2), micro USB Type A to C cable, 1.5V AA batteries (4), instruction manual, quick start guide, instrument quality certificate and a rugged carrying case. Increased Traceabilty Ensure that your data can be trusted with GLP data. Accessible by a fixed dedicated key, this data includes date, time, pressure, calibrated value, temperature and salinity value of the last calibration. Versatile Data Logging The meter log-on-demand feature allows you to store up to 4000 readings. The AutoEnd button can be used during measurement to hold the first stable reading on the display automatically. Smart Cap Technology and Automatic Cap Recognition Smart Caps feature a built-in RFID reader that is able to store important data, including manufacture date and first-use date for increased traceabilty. Quick Connect Probe The Quick Connect fitting is designed for quick and easy installation of the DO probe. A watertight connection without threads make attaching and removing the probe simple. | 1 | Nos |