- Home
- >
- Tender
- >
- Telangana Tender
- >
- Department of Military Engineer Services
- >
NTID 44851897
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowSpecial Repairs Replacement Of in Hyderabad-T - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Special Repairs Replacement Of" in Hyderabad-T, India.
Military Engineer Services
Hyderabad-T, Telangana, India
NTID 44851897
- Opening Date : Wed 29th April, 2026
- Closing Date : Mon 27th April, 2026
- ₹ 4855000.00
- NTID 44851897
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
97100.00 -
Document Cost
500.00 -
Estimated Cost
4855000.00
BOQ Items Total Items : 30 | Total Qty : 10122.6
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Supply, install, commissioning & testing of Motor Control Panel "out-door type" of size 900 mm (height) x 900 mm (breadth) x 500 mm (depth) (minimum dimensions) factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB/MCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) incl taking down old unsv one complete all as specified & as directed & to the entire satisfaction of the Engr-In-Charge with & incl the following accessories : [ For Watch Tower Borewells ] | 16.0 | Each Job |
| 2 | BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos high grade Aluminium 100 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes. INCOMING : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 25 KA & of rating 20 to 32 A - 01 Nos. Make : Cat No : DZ0F0020-32CXC1AOOOO of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS. OUTGOINGS : (a) MCB, SPN, 10KA, 230V, "C" curve, 06-32 A, ISI marked - 03 Nos (2W + 1S). Make : LEGRAND/ABB/SIEMENS (b) Single Phase DOL Starter perfectly suitable for Submersible Pumping Set of capacity upto 2 HP, conforming to IS/IEC : 60947-4-1, IP-54, with & incl Extended wide band coil, FRLS Copper Internal Wiring, Starter Type - Air Break, Class-H Insulation with Contactor Rating - 12A, Overload Relay Range - 2.8A to 4.2A incl testing complete. Make : SIEMENS/L&T/HAVELLS/BCH - 02 Nos (1W + 1S) INSTRUMENTATION SYSTEM : (a) Digital type Multi-Function meter with built in selector Switch & 03 Nos CTs matching with the I/C breaker, Accuracy Class - 1.0, 3 phase, Size 96 x 96 mm. Make : Cat No WL411010OOOO of make L&T or techno-commercially equivalent of ELMEASURE/SECURE. (b) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos (Front & Back). | ||
| 3 | Supply, install, commissioning & testing of Motor Control Panel "out-door type" of size 1200 mm (height) x 1000 mm (breadth) x 600 mm (depth) (minimum dimensions) factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB/MCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) incl taking down old unsv one complete all as specified & as directed & to the entire satisfaction of the Engr-In-Charge with & incl the following accessories : [ For Other Borewells ] | 6.00 | Each Job |
| 4 | BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos high grade Aluminium 100 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes. INCOMING : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 25 KA & of rating 40 to 50 A - 02 Nos. Make : Cat No : DZ0F0050CXC1AOOOO of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS. (b) Compact Enclosed ATS (Automatic Transfer Switch) suitable for inside panel mounting & I-O-II operation, 4 Pole, 63 A, confirming to IEC 60947-6-1 - 01 No complete with following features/specifications : (i) Double-Break Contact System offering High Short-time Withstand. (ii) Ample Space for Cable Termination. (iii) Ease of Generator Control (ON-OFF, Cooling Cycle Self-Test). (iv) Cyclic Event Logger. (v) Priority Source Selection. (vi) Adjustable Time Delay (0.1 Sec to 3 Hrs). (vii) Suitable for 3-Phase as well as 1-Phase sources. (viii) Protections - UV/OV, Phase Sequence, Single Phasing, Frequency. (ix) Terminal Shrouds, Phase Barriers & Source Separator etc. Cat No : 1SYN151254R1001 of make ABB or techno-commercially equivalent of L&T/Siemens. | ||
| 5 | OUTGOINGS : (a) MCB, TPN, 10KA, 415V, "C" curve, 40-63 A, ISI marked - 03 Nos (2W + 1S). Make : LEGRAND/ABB/SIEMENS (b) Three Phase Fully Automatic Starter perfectly suitable for Submersible Pumping Set of capacity upto 15 HP, conforming to IS/IEC : 60947-4-1, IP-54, with & incl Single Phasing Protection (SPP) with Auto Manual Switch, FRLS Copper Internal Wiring, Combined V / A Meter, Voltmer Selector Switch, ON / OFF Indication, Star-Delta Timer etc., Class-H Insulation with Contactor Rating AC3 (A) - 20A, Overload Relay Range - 13.2A to 20A incl testing complete. Make : SIEMENS/L&T/HAVELLS/BCH - 02 Nos (1W + 1S) INSTRUMENTATION SYSTEM : (a) Digital type Multi-Function meter with built in selector Switch & 03 Nos CTs matching with the I/C breaker, Accuracy Class - 1.0, 3 phase, Size 96 x 96 mm. Make : Cat No WL411010OOOO of make L&T or techno-commercially equivalent of ELMEASURE/SECURE. (b) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos (Front & Back). NOTE: 1) Design / drawing / BOM of the Panel Board incl all accessories showing the dimensions is to be obtained from the Manufacturer / Supplier & is to be got approved from the Engr-In-Charge & GE before placing final order to the manufacturer. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. 3) The electrical connection of digital Multi Functional Meter in the MCC panel is to be done from load side so that monitoring of various parameters viz. Voltage, Current, KW, KVA, power factor, frequency etc. can be done for both SEB mains & DG mains. 4) Necessary PCC foundation/plinth shall be as per the recommendations of OEM / Supplier etc. & cost of the same is deemed to be included in the quoted rates. |
Purchase Access To Download Selected Documents