- Home
- >
- Tender
- >
- Karnataka Tender
- >
- Department of Military Engineer Services
- >
NTID 43004667
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowCorrigendum Special Repairs in Bangalore - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Corrigendum Special Repairs " in Bangalore, India.
- Opening Date : Mon 12th January, 2026
- Closing Date : Mon 5th January, 2026
- ₹ 14050000.00
- NTID 43004667
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
215500.00 -
Document Cost
1000.00 -
Estimated Cost
14050000.00
Latest Corrigendum List
| # | Corrigendum Title | Corrigendum Type |
|---|---|---|
| 1 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum |
| 2 | BOQ Revised | BOQ |
BOQ Items Total Items : 94 | Total Qty : 28449.2
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Supply, installation, testing & commssioning of HT 11 kV, 3 Ph, 50 Hz totally enclosed ( metal enclouser) SF6 gas insulated switchgear having rated current carrying capacity upto 630 A, with 02 way Outdoor Ring Main Unit with 2 Isolator , (type CC+) , CU busbar,Type 2 way manual operated, outdoor, one side -extensible, outdoor comprising of (2 LBS) , rated power frequency voltage 28 kV, rated impulse withstand voltage 75 kV, rated current for ring main feeder - 630 A, ambient temperature (-5 deg to +55 deg celsius), design ambient temperature (40 degree C), including foundation as per OEM recommendation complete all as directed . The Cable boxes shall be suitably provided towards front/rear side, for 1 X 3C x 120 sq mm XLPE Cable with right angle Cable Termination protectors complete all as specified and as directed. | 4.00 | EACH JOB |
| 2 | Supply, installation, testing & commssioning of HT 11 kV, 3 Ph, 50 Hz totally enclosed ( metal enclouser) SF6 gas insulated switchgear having rated current carrying capacity upto 630 A, with 03 way Outdoor Ring Main Unit with 3 Isolator , (type CCC+) , CU busbar,Type 3 way manual operated, outdoor, one side -extensible, outdoor comprising of (3 LBS) , rated power frequency voltage 28 kV, rated impluse withstand voltage 75 kV, rated current for ring main feeder - 630 A, ambient temperature (-5 deg to +55 deg celsius), design ambient temperature (40 degree C), including foundation as per OEM recommendation complete all as directed . The Cable boxes shall be suitably provided towards front/rear side, for 1 X 3C x 120 sq mm XLPE Cable with right angle Cable Termination protectors complete all as specified and as directed. | 1.00 | EACH JOB |
| 3 | Supply, installation, testing & commssioningof HT 11kV,3Ph,50Hz totally enclosed( metal enclouser) SF6 gas insulated switchgear having rated current carrying capacity upto 630A, with 03 way Outdoor Ring Main Unit with 2 Isolator , 1 VCB ( type CCV+) with 01 set of Protection CT of ratio 60/1A , 2.5VA , 5P10 - 1 set for each VCB, STC 21kA for 3Sec ,IAC AFLR 21kA for 1sec ,CU busbar,Type 3 way manual operated,outdoor,one side -extensible,oudoor comprising of (2 LBS+1 VCBs) in a single unit (VCB to be manual), rated power frequency voltage 28kV,rated impluse withstand voltage 75kV,rated current for ring main feeder -630A,rated current for VCB 630A,short time current (ik)-21kA for 3sec,rated short making current 50kV,ambient temperature (-5deg to +55deg celsius),design ambient temperature (40degree C),with IP 54 Each Vacuum Circuit breaker including foundation as per OEM recommendation complete all as directed . The Cable boxes suitable towards front/rear side, for 1 X 3C x 400 sq mm XLPE Cable as incomer & 1x 3C x 120 sqmm as outgoing with right angle Cable Termination protectors complete all as specified and as directed. | 1.00 | EACH JOB |
| 4 | Note for item Ser No 1 to 3 :- (a) Only OEM make RMUs are acceptable. RMUs manufactured & supplied in the name of System integrator / Franchise partners /License Partners of OEM are not acceptable. SF6 Gas tank, RMU shall be manufactured by OEM in whose name for type tests are issued. | ||
| 5 | (b) Load break switch (630A) should have the following :- (i) Manual operated 12 KV, 630A Load Break switch and Earthing Switch with making capacity (ii) Live Cable LED Indicators through Capacitor Voltage Dividers mounted on the bushings (iii) Mechanical ON/OFF/EARTH Indication (iv) Anti-reflex operating handle (v) Cable Testing facility after opening the cable covers after doing the earthing suitably and without disconnecting the Cable terminations. (vi) Cable boxes suitable for 1x3Cx120 sq mm XLPE Cable with right angle Cable Termination Protectors |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054