- Home
- >
- Tender
- >
- Andhra Pradesh Tender
- >
- Department of Military Engineer Services
- >
NTID 47149145
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowSpecial Repairs Of Building No in WALTAIR - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Special Repairs Of Building No" in WALTAIR, India.
Military Engineer Services
WALTAIR, Andhra Pradesh, India
NTID 47149145
- Opening Date : Wed 25th November, 2026
- Closing Date : Tue 17th November, 2026
- ₹ 74900000.00
- NTID 47149145
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
699500.00 -
Document Cost
3000.00 -
Estimated Cost
74900000.00
BOQ Items Total Items : 621 | Total Qty : 147643.03
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Removal existing treatment any type, any thickness and roughening the surfaces of old concrete floor or concrete surfaces by picking, sweeping clean and washing down with water to remove dust, etc., brushing neat cement slurry with 3 Kg., of cement per square metre, laying 25 mm thick PCC 1:2:4 type B1 (using 20 mm graded aggregate ) laid on RCC slab to make surface levelled for proper slope finished even and fair, rendering 10 mm thick in CM 1:4 on concrete srfaces to make surface smooth to receive water proof treatment including mixing WPC as per manufacturing instructions, Supply and lay hyperlas standard 3 Kg/Sqm polymeric water proofing membrane incorporating a centre core of 90 micron thick HMHDPE film including coating the surface with a coat of water based bituminous primer @ 100 gms/sqm followed by a coat of blown bitumen of grade 85/25 or 90 /15 @ 1.2 Kg/Sqm each at top and bottom of the membrane followed by a coat of bituminous aluminium primer @ 100 gms/Sqm complete including sealing all joints by thermo fusion with minium 10 cm overlap all as per manufacturer's instructions, M&L for cool roof tiles of size 300 x 300 x 7mm thick & SRI value more than 90 as on roof laid over screed bed over bedding layer of mortor 10mm thick in cement mortor 1:4 joint shall be kept as 3mm filled with epoxy grout and masking tape shall be put before putting the epoxy grout , grout shall be througly cleaned immediatlely complete all as specified and directed from 13th Storey to 16th Storey complete all as specified and as directed. Note : The colour / shade / design of tile shall be as approved by GE | 412.31 | Sqm |
| 2 | Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15 cm thickness complete all as specified and as directed. | 91.62 | Cum |
| 3 | Demolition of un-reinforced Cement Concrete including tiles of any description and in any position not otherwise specifically provided for complete all as specified and as directed. | 87.21 | Cum |
| 4 | All as per above item No. 3 but from 5th Storey to 8th Storey | 87.21 | Cum |
| 5 | All as per above item No. 3 but from 9th Storey to 12th Storey | 87.21 | Cum |
Purchase Access To Download Selected Documents