- Home
- >
- Tender
- >
- Tamil Nadu Tender
- >
- Department of HLL Biotech Limited
- >
NTID 44364718
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowRevival Testing And Commissio in Kanchipuram - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Revival Testing And Commissio" in Kanchipuram, India.
HLL Biotech Limited
Kanchipuram, Tamil Nadu, India
NTID 44364718
- Opening Date : Tue 17th March, 2026
- Closing Date : Mon 16th March, 2026
- ₹ 11076371.00
- NTID 44364718
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
276909.00 -
Document Cost
2950.00 -
Estimated Cost
11076371.00
BOQ Items Total Items : 348 | Total Qty : 25601.9
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | HVAC WORKS | ||
| 2 | SCHEDULE-A | ||
| 3 | AHU General Servicing, Testing & Commissioning | ||
| 4 | Providing comprehensive general servicing, testing, and commissioning of existing Air Handling Units (AHUs) commencing with safe power isolation (lockout-tagout), followed by opening of access panels for pharma-grade cleaning and disinfection of all internal sections (blower, coil, drain pan, plenum) using approved non-corrosive agents compliant with WHO GMP; detailed inspection and servicing of the plug fan assembly including fan wheel cleaning/balancing, bearing condition check with lubrication/greasing, motor mounting/alignment verification, and tightening of foundation bolts; motor health assessment through insulation resistance testing, voltage/current/RPM/power factor measurement, and checks for abnormal noise, vibration, or temperature rise; thorough chemical cleaning and high-pressure flushing of cooling coil to remove dust, grease, microbial deposits, and biofilm, with fin straightening as needed, along with complete cleaning and disinfection of SS-304 drain pan, condensate line, and U-trap to ensure free drainage; verification of casing panels, doors, gaskets, and seals for air leakage and proper sealing; inspection of local AHU control panel for terminal tightness, contactors, overload relays, VFD (if applicable), earthing continuity, and BMS interface points; reassembly using new perished gaskets/seals; followed by energization, no-load trial run for smooth operation and absence of abnormal noise/vibration, full operational testing of airflow (CFM), static pressure, fan performance against design curves, cooling coil response, condensate drainage, and damper functionality (where motorized), with recording of all parameters (current, voltage, RPM, vibration, noise, airflow, pressure) and comparison against OEM specifications; final commissioning to confirm achievement of design parameters for airflow, static pressure, and overall system stability as per ISHRAE/ASHRAE guidelines, approved drawings, and site Engineer-in-Charge instructions, complete with detailed servicing and test report including before/after observations and test readings | ||
| 5 | General Servicing, Testing and Commissioning of Double Decked AHU |