- Department of Cochin Shipyard Limited
- >
NTID 43067057
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowCorrigendum Replacement Of L in Ernakulam - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Corrigendum Replacement Of L" in Ernakulam, India.
- Opening Date : Fri 16th January, 2026
- Closing Date : Thu 15th January, 2026
- ₹ 3386312.00
- NTID 43067057
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
57395.00 -
Document Cost
Refer Documents -
Estimated Cost
3386312.00
Latest Corrigendum List
| # | Corrigendum Title | Corrigendum Type |
|---|---|---|
| 1 | Corrigendum 1 | Date |
| 2 | Corrigendum 2 | Technical Bid |
BOQ Items Total Items : 4 | Total Qty : 8
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Design, fabrication, supply of Type Tested LT panel in 2RD substation in compliance with IEC 61439 Part 1 & 2. The details of the LT panel is as given below. Please refer technical specification for complete details. 1. Busbar: TPN Al. 2. Incomer Breaker: ACB: 2000A, 4-pole, 50kA, electrically operated, draw-out type with p based LSIG protection 1 No. 3. Incomer Bus duct: 2500A, TPN, Al. (5 mtr aprrox.) 4. Outgoing Breakers a) MCCB: 400A, 4-pole, 36kA, thermal-magnet overload type 2 Nos b) MCCB: 630A, 4-pole, 36kA, thermal-magnet overload type 3 Nos c) MCCB: 250A, 4-pole, 36kA, thermal-magnet overload type 1 No d) MCCB: 100A, 4-pole, 25kA, thermal-magnet overload type 1 No e) ACB: 2000A, 4-pole, 50kA, electrical operation, draw-out type with p based LSIG protection 1 No f) ACB: 1600A, 4-pole, 50kA, electrical operation, draw-out type with p based LSIG protection 1 No g) ACB: 1250A, 4-pole, 50kA, electrical operation, draw-out type with p based LSIG protection 2 Nos h) ACB: 800A, 4-pole, 50kA, electrical operation, draw-out type with p based LSIG protection 1 No 5. Metering & Indications a) RYB indication on incomer b) ON/OFF/TRIP indication on incomer and all outgoings c) RS485 enabled Multifunction (V, A, f, kW, kWh) meters on incoming and all outgoings. | 1 | No |
| 2 | Dismantling and shifting of the existing LT panel & BBT by disconnecting all the cables, installation of new LT panel including termination of existing cables with necessary glands and lugs as required, earthing the new panel etc. as per technical specification and scope of work. | 1 | L.S. |
| 3 | Supply of tinned Aluminium, 2500 A sandwiched busbar (approx 5 meter) and accessories with necessary supports and Cu earth conductors as per the technical specification. | 5 | m |
| 4 | Installation and commissioning of 2500 A sandwiched busbar (approx 5 meter) and accessories with necessary supports and Cu earth conductors after disconnection and dismantling of existing busbar as per technical specification and scope of work. | 1 | L.S. |