- Home
- >
- Tender
- >
- Chhattisgarh Tender
- >
- Department of Airports Authority of India
- >
NTID 42868760
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowReplacement Of Cooling Towers in Bhatgaon - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Replacement Of Cooling Towers " in Bhatgaon, India.
Airports Authority of India
Bhatgaon, Chhattisgarh, India
NTID 42868760
- Opening Date : Mon 15th December, 2025
- Closing Date : Fri 12th December, 2025
- ₹ 6645092.00
- NTID 42868760
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
199353.00 -
Document Cost
1180.00 -
Estimated Cost
6645092.00
BOQ Items Total Items : 34 | Total Qty : 5003
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | SH-I: Electrical Works | ||
| 2 | Supply, installation, testing and commissioning of FRP/ GRP (Glass reinforced polystyrene) induced draft based Single cell rectangular shape induced draft counter flow type cooling towers for airconditioning system. Each tower shall be complete with basin, casing distribution system, filling fills, hot deep galvanised (HDG) supportors, GI ladders, motor (IP55 protection) suitable for 415 10% volts, 3 phase power supply, 50 Hz and high efficiency (IE-4) moter, isolators provision at cooling tower enclosed in weather proof panel, Emergency Stop Switch, sump temperature sensors complete as per specification as required. Cooling Towers system shall be selected on the basis of ambient wet bulb 82.94 degree F and actual capacity as follows: Nominal Capacity : 387.8 TR (Heat rejection - 11,61,753 kcal/hr) Water flow rate : 1218 USGPM Water temp. in : 37 C Water temp. out : 32 C Note: Selection of Moter shall be as per AAI approval. | 4 | Job |
| 3 | Supply, Installation, Testing and Commissioning of Centrifugal Split Casing Pump with bronze and corro coating factory assembled on a common base duly aligned with electric motor (efficiency IE4) for recirculation of water for the central air conditioning system. The pump motor shall be suitable for 415 + 10% volts, 50 Hz, 3 phase power supply including base plate, vibration isolation pad, rubber expanasion bellow, mechanical seals, drain connection remote start stop push buttons etc. complete as required including providing and laying in position cement concrete 1:2:4 (1 Cement : 2 Coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump including form work etc. as required Condenser Water Pump Motor specification as follows : Water flow rate : 1218 USGPM each Head : Minimum 20 Mtr. Pump Efficiency : Minimum 75% Note: Selection of Moter and pumps shall be as per AAI approval. | 4 | Job |
| 4 | Supply fixing, testing and commissioning of condenser water pipes of following sizes of MS C class along with necessary clamps, vibration isolators and fittings such as bends,tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. | ||
| 5 | 250 mm dia MS pipes ('C' Class) | 18 | Mtr. |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054