- Home
- >
- Tender
- >
- West Bengal Tender
- >
- Department of Military Engineer Services
- >
NTID 42971049
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowRepair Replacement Of 11 Kv Ht in Darjeeling - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Repair Replacement Of 11 Kv Ht" in Darjeeling, India.
Military Engineer Services
Darjeeling, West Bengal, India
NTID 42971049
- Opening Date : Mon 29th December, 2025
- Closing Date : Fri 26th December, 2025
- ₹ 7500000.00
- NTID 42971049
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
137500.00 -
Document Cost
1000.00 -
Estimated Cost
7500000.00
BOQ Items Total Items : 154 | Total Qty : 23463
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | M&L for carrying out the Periodical Check and preventive maintenance/servicing of HT RMU (Ring Main unit) and SF6 circuit breaker 11 KV, 630A/400A installed in Compact sub station and other location under GE Bengdubi as per existing make alongwith tripping system and mechanism and carried out the fwg repair/tests made for smooth operation.: (a) Cleaning and greasing of mechanism. (b)Tightning testing of mechanism parts. (c) Alignment testing and adjustment of mechanism.(d) Operation, testing of trip and close by electrical and manual mode. (e) Spring charging testing by electrical and manual mode.(f) Cleaning of panel insulator CT &PT unit of the panel. (g) Cleaning and tightning of control/wiring CT &PT unit.(h) Cleaning and testing of relay with current injection method (j) Testing of auxillary relay.(k) Allingment of trolley, checking/greasing of shutter /lock of breaker.(l) Testing of polarities of CTs.(m)Checking and recording of IR Values of VCBs trolley and Panel of RMU (n) Settings and coordination of relays. (o) Checking/repairing/rectification of the control wiring (p) Replacement of panel heater.(q) Replacement of worn out bushing PT/Busbar support insulators rusted nut bot with suitable size of stainless steel nuts, bolts and washers.(r) Replacement of unserviceable open circuit CTs. (s) Replacement of unserviceable Relay, Push botton, Indicator light HRC fuse etc.(t) High voltage testing with high voltage tester of CT & Breaker Pole to withstand working pressure of HT 11 KV to ascertain serviceability and spare parts found defective to be replaced for smooth functioning as directed by the GE (u) Testing the leakage of SF6 gas of the RMU and refilling the gas SF6. (v) Complete servicing, overhauling and testing of 11 KV ring main unit (including for Breakers) shall be got done by the contractor from the authorised agency. (w) Any part/spare found defective during testing shall be repaired/replaced for which payment shall be made separately against respective items here in after except for minor parts such as packing, nuts bolts, cotton waste etc for which cost shall be deemed to be included in the unit rate quoted for this item. (x) Contractor shall deposit / Procure all the material in advance to avoid any late night fault/ after market hours / non availability of material in market. Note : (a) The elect supply shall be restore within 5 hours from the time of tripping / fault in day or night in the stn, failing this a penalty of Rs 5000/- per complaint / fault will be imposed on the contractor from contractor dues. (b) The cost of Disconnection and connection after repair, included in quoted rate. | 5.00 | Each Job |
| 2 | Supply only SF-6 gas in 11 KV RMU and properly sealed and check the the leakage of gas and maintain suitable prressure to smoothly charge the breaker and test tripping and closing of the circuit and checked the pressure as per IE rule and leakage complete all as specified and directed. | 7.00 | Kg |
| 3 | Supply only closing coil 24V DC for 11 KV RMU as per existing make and model of any make RMU complete all as specified and directed. | 5.00 | Each |
| 4 | Supply only triping coil 24V DC for 11 KV RMU as per existing make and model of any make RMU complete all as specified and directed. | 5.00 | Each |
| 5 | Supply only cast resign CT unit 50/5-5A, 15 VA for 11 KV RMU as per existing make and model of any make RMU complete all as specified and directed. | 2.00 | Set of Three |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054