Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
28540.00 -
Document Cost
5000.00 -
Estimated Cost
1427000.00
BOQ Items Total Items : 16 | Total Qty : 16
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Repair & maintainance of Air Handling Unit at operation Theatre No:-1 Model no:-ZDS-20 AIR QUANTITY :- 2000 CFM (serial no-Not visible) Work Addresses following components:- 1)Pre-Filter Replacement :600mm X 600MM X 300MM-4 Nos.Box type filters. 2)Final Filter Replacement :610mm X 610mm X 300mm-1 nos. Flange type filters. 3)Return Air Damper & Outside Air Damper Repair Inspecting and repairing issues with the return air damper and outside air damper. 4)Cooling Coil :Inspecting ,Cleaning and repairing 5)Supply fans :Checking for wear ,lubricating and repairing.6)Moisture Eliminators :Replace. 7)Sound Attenuator:Inspect and Repairing. 8)Exhaust Return Fan: checking proper operation. 9)Lubricating moving parts,tighten connections,and calibrating controls .10)Actuator:Inspect and address any damage. 11)Sensors:Maintenance of Reurn Air,Outdoor Air waterflow,Airflow,supply Air Sensors. 12)Electric Motors: Maintenance of Fans,Belts and bearings. 13)Changing of Belts:-A-39 V Belts-2 nos. 14)Strainer:Inspection,Clean, and repair. 15)Valves:Inspect,Repair & change. 16)Electric Connections & Switches:Check for proper operation and repair. 17)Heating Coil/Humidfier:Installation of Heating Coils/Humidifier:Installation of Heating coils/Humidifier in AHU for proper functioning at the climate of Goa region. | 1.000 | Job |
| 2 | Repair & Maintainance of Air Handling Unit at operation Theatre No:-2 Model no:-ZDS-20 AIR QUANTITY :- 2000 CFM (serial no-Not visible) Work Addresses following components:- 1)Pre-Filter Replacement :600mm X 600MM X 300MM-4 Nos.Box type filter. 2)Final Filter Replacement :610mm X 610mm X 300mm-1 nos. Flange type filters. 3)Return Air Damper & Outside Air Damper Repair:Inspecting and repairing issues with the return air damper and outside air damper. 4)Cooling Coil :Inspecting ,Cleaning and repairing. 5)Supply fans :Checking for wear ,lubricating and repairing. 6)Moisture Eliminators :Replace. 7)Sound Attenuator:Inspect and Repairing. 8)Exhaust Return Fan: checking proper operation. 9)Lubricating moving parts,tighten connections,and calibrating controls.10)Actuator:Inspect and address any damage. 11)Sensors:Maintenance of Reurn Air,Outdoor Air waterflow,Airflow,supply Air Sensors. 12)Electric Motors: Maintenance of Fans,Belts and bearings. 13)Changing of Belts:-A-39 V Belts-2 nos. 14)Strainer:Inspection,Clean, and repair. 15)Valves:Inspect,Repair & change. 16)Electric Connections & Switches:Check for proper operation and repair. 17)Heating Coil/Humidfier:Installation of Heating Coils/Humidifier:Installation of Heating coils/Humidifier in AHU for proper functioning at the climate of Goa region. | 1.000 | Job |
| 3 | Repair & Maintainance of Air Handling Unit at operation Theatre No:-3 Model no:-ZDS-20 (serial no-Not visible) AIR QUANTITY :- 2000 CFM Work Addresses following components:- 1)Pre-Filter Replacement :600mm X 600MM X 300MM-4 Nos.Box type filter. 2)Final Filter Replacement :610mm X 610mm X 300mm-1 nos. Flange type filters. 3)Return Air Damper & Outside Air Damper Repair:Inspecting and repairing issues with the return air damper and outside air damper. 4)Cooling Coil :Inspecting ,Cleaning and repairing. 5)Supply fans :Checking for wear ,lubricating and repairing. 6)Moisture Eliminators :Replace. 7)Sound Attenuator:Inspect and Repairing. 8)Exhaust Return Fan: checking proper operation. 9)Lubricating moving parts,tighten connections,and calibrating controls. 10)Actuator:Inspect and address any damage.11)Sensors:Maintenance of Reurn Air,Outdoor waterflow,Airflow,supply Air Sensors. 12)Electric Motors: Maintenance of Fans,Belts and bearings. 13)Changing of Belts:-A-39 V Belts-2 nos. 14)Strainer:Inspection,Clea, and repair. 15)Valves:Inspect,Repair & change. 16)Electric Connections & Switches:Check for proper operation and repair.17)Heating Coil/Humidfier:Installation of Heating Coils/Humidifier:Installation of Heating coils/Humidifier in AHU for proper functioning at the climate of Goa region. | 1.000 | Job |
| 4 | Repair & Maintainance of Air Handling Unit at operation Theatre No:-4 Model no:-ZDS-20 AIR QUANTITY :- 2000 CFM (serial no-Not visible) Work Addresses following components:- 1)Pre-Filter Replacement :600mm X 600MM X 300MM-4 Nos.Box type filters. 2)Final Filter Replacement :610mm X 610mm X 300mm-1 nos. Flange type filters. 3)Return Air Damper & Outside Air Damper Repair Inspecting and repairing issues with the return air damper and outside air damper. 4)Cooling Coil :Inspecting ,Cleaning and repairing 5)Supply fans :Checking for wear ,lubricating and repairing. 6)Moisture Eliminators :Replace. 7)Sound Attenuator:Inspect and Repairing. 8)Exhaust Return Fan: checking proper operation. 9)Lubricating moving parts,tighten connections,and calibrating controls. 10)Actuator:Inspect and address any damage. 11)Sensors:Maintenance of Reurn Air,Outdoor Air waterflow,Airflow,supply Air Sensors. 12)Electric Motors: Maintenance of Fans,Belts and bearings. 13)Changing of Belts:-A-39 V Belts-2 nos. 14)Strainer:Inspection,Clean, and repair. 15)Valves:Inspect,Repair & change. 16)Electric Connections & Switches:Check for proper operation and repair. 17)Heating Coil/Humidfier:Installation of Heating Coils/Humidifier:Installation of Heating coils/Humidifier in AHU for proper functioning at the climate of Goa region. | 1.000 | job |
| 5 | Repair and maintainance of Air Handling Unit at office no.1 Model no:-ZDS-100 AIR QUANTITY :- 9600 CFM (serial no-Not visible) Work Addresses following components:- 1)Pre-Filter Replacement :600mm X 600MM X 50MM-4 Nos.Box type filters. 2)Final Filter Replacement :600mm X 300mm X 300mm-2 nos. Flange type filters. 3)Return Air Damper & Outside Air Damper Repair Inspecting and repairing issues with the return air damper and outside air damper. 4)Cooling Coil :Inspecting ,Cleaning and repairing 5)Supply fans :Checking for wear ,lubricating and repairing. 6)Moisture Eliminators :Replace. 7)Sound Attenuator:Inspect and Repairing. 8)Exhaust Return Fan: checking proper operation. 9)Lubricating moving parts,tighten connections,and calibrating controls. 10)Actuator:Inspect and address any damage. 11)Sensors:Maintenance of Reurn Air,Outdoor Air waterflow,Airflow,supply Air Sensors. 12)Electric Motors: Maintenance of Fans,Belts and bearings. 13)Changing of Belts:-A-39 V Belts-2 nos. 14)Strainer:Inspection,Clean, and repair. 15)Valves:Inspect,Repair & change. 16)Electric Connections & Switches:Check for proper operation and repair. 17)Heating Coil/Humidfier:Installation of Heating Coils/Humidifier:Installation of Heating coils/Humidifier in AHU for proper functioning at the climate of Goa region. | 1.000 | job |