- Home
- >
- Tender
- >
- Haryana Tender
- >
- Department of Kurukshetra University
- >
NTID 47072315
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowRenovation Of Assembly Hall Of in Kurukshetra - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Renovation Of Assembly Hall Of" in Kurukshetra, India.
Kurukshetra University
Kurukshetra, Haryana, India
NTID 47072315
- Opening Date : Mon 2nd November, 2026
- Closing Date : Mon 2nd November, 2026
- ₹ 16563608.00
- NTID 47072315
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
331275.00 -
Document Cost
17700.00 -
Estimated Cost
16563608.00
BOQ Items Total Items : 46 | Total Qty : 1866.73
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | `Checking of Measurements of all works at site with respect to Detailed Estimate / Technically Sanctioned Estimate, DNIT and checking of all data viz bill, measurements etc. uploaded on HEWP by contractor and executing all other related activities including supervision of work, as per direction of Engineer-In-Charge complete in all respects. Note- Atleast Minimum Wages as per Latest HKRNL Wage Rates to be paid for Category-II District, Level-III Jobs. | 12 | Per Month |
| 2 | Excavating, supplying and filling of Tibba Sand having CBR 8% (including royalty) by mechanical transport upto any lead and Lift also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. | 27.98 | cum |
| 3 | Wooden Acoustical Slats Wall Paneling (with one mm laminate).Providing and fixing Tongue and Groove Wooden Acoustical Panels of size 190 X 2440 X 16 mm with micro perforation (3mm) In Front Side And 10mm Circular Hole Covered With Acoustical Fleece To Get (NRC 0.7). The Wooden Panel made of a High Density Fiber Board (HDMR) Substrate with one (1) mm Laminated (Mica) facing as per the approved Shade/species and finish, and a Melamine balancing layer over the reverse side. The density of HDMR board should be more than 800kg/m3. The HDMR board should be passed through vertically flammability test (UL94) and should be tested as for Anti-Fungal, The Panels with the help of special design Z clip as per the Drawing and Design would be fixed on the Aluminum Channel of size 15x25x19x7x.70mmx 3000mm Horizontally/Vertically over Gl frame work for wall paneling as per design drawing consisting of floor channel of size 50x32x32 x0.5mm thick at bottom and top fixed with 35 mm nylon sleeves and 35 mm screw. Further fixing Gl stud 48x34x36x0.5 mm thick @600mm C/C vertically. The framework to be filled with 50mm 1000 GSM non-woven thermal bonded polyester wadding held in position with 18 mm Gl chicken mesh of 24SWG with drywall screws and oversize washers. Finally fixing over it horizontally 80x26x51x0.5 mm thick G.J. ceiling section placed @600mm C/C or wherever required as per design drawings with dry wall screws and angle cleats 27x37x25x1.6 mm as required. The frame to be fixed to the walls by means of angle hold fastener cleats of required size, complete with expandable anchor fasteners of 65x10mm dia fixed on each vertical member @1000mm C/C. etc. as required, all complete as per the directions of Engineer-in-Charge | 400.88 | Sqm |
| 4 | Fabric Acoustical Wall Paneling (0.9NRC):Providing and fixing of Fabric Acoustical Wall Paneling with square edges made of Rockwool with Glass-wool Tissue substrate 25mm thick and wrapped on the front side with an acoustically transparent and fire-resistant fabric with an option of colors as per the choice of the Architect/ Engineering- in charge of size 600x1200 or 600x600 mm providing a minimum sound absorption level of 0.90 NRC. The Gl Metal system includes G.I Stud having Size 48 mm X 36 mm x 34 mm X 0.50mm, length 3600mm and Floor Channel Size 50 mm X 32 mm X 32 mm X 0.50 mm, length3600 mm is fastener vertically/ horizontally at every 600mm filled with 50mm 1000 GSM nonwoven thermal bonded polyester wadding. Then 8 mm HDMR perforated Board should be Screwed to the Gl frame with the help of 25X 6 mm metal screw 25mm thick fabric acoustical panel should be pasted on the 8 mm HDMR perforated Board with the help of rubber base Adhesive of Pidilite or equivalent make as per drawing and design of Engineer-in Charge. | 123.07 | Sqm |
| 5 | 20mm PET ACOUSTICAL PANELS:Providing and fixing 20 mm Pet acousitcal wall panel made of 11 mm perforated HDMR board as base and 9 mm pet acoustical panel pasted on the HDMR board in linear/approved shape. The Pet acoustical panel should be fixed on Gi frame work for wall paneling as per design drawing consisting of floor channel of size 50x32x32x0.5mm thick at bottom and top fixed with 35 mm nylon sleeves and 35 mm wooden screw. Further fixing Gl stud 48x34x36x0.5 mm thick @600 mm C/C vertically and Horizontally. The framework to be filled with 50mm 1000 GSM non-woven thermal bonded polyester wadding held in position with drywall screws and oversize washers. The frame to be fixed to the walls by means of angle cleats of required size complete with expandable anchor fasteners of 65x10mm dia fixed on each vertical member @1000mm C/C etc. as required all complete as per the directions of Engineer-in-Charge. Pet acoustical panel of size 190 X 2440 X 20 adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main `T`. The system should rest on periphery walls /partitions with the help of Gl perimeter wall angle of size 22x19x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic raw I plug at 450 mm centre to centre and 40 mm long dry wall S.S. screws. The exposed bottom portion of all T- sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. (Supplier Company should be OEM and same Test Certificates will be required from contractor before billing of the item). The work shall be carried out as per specifications, drawings and as per directions of the Engineer-In-Charge. | 215.2 | Sqm |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054