- Home
- >
- Tender
- >
- Odisha Tender
- >
- Department of Indian Oil Corporation Limited
- >
NTID 45788906
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowRefilling And Hydrotest Of Fm- in Paradip - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Refilling And Hydrotest Of Fm-" in Paradip, India.
- Opening Date : Mon 20th July, 2026
- Closing Date : Fri 17th July, 2026
- ₹ 0.00
- NTID 45788906
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
Refer Documents -
Document Cost
Refer Documents -
Estimated Cost
Refer Documents
BOQ Items Total Items : 43 | Total Qty : 373.015
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | GST % for the tender Please select the rate of GST in cell W13. Rate selected shall be applicable for the entire BoQ. | ||
| 2 | FM-200 Cylinder at SERPL Vizag | ||
| 3 | Supply of approved and certified Clean Agent FM200: Supply of FM-200 gas (HFC 227ea) complying with NFPA Standard 2001 (latest) and certified FM200 clean agent in 2 number of cylinders (details attached separately.) The Vendor has to submit the authorization documents issued by the original manufacturer Refilling of nitrogen-pressurized HFC227ea extinguishing cylinders, each cylinders to be pressurized as per design Necessary certificate is required to be submitted along with the gas supply. | 17.71 | KG |
| 4 | 1. Statutory Hydro-Static Pressure Testing of FM200 gas Cylinders from CCoE/ PESO Approved testing agency. Required test certificates to be issued to IOCL about successful testing and passing the test standards of the cylinders. 2. Ultrasonic Thickness Inspection to be carried out after hydro test and report to be submitted. 3. Painting of cylinder to be carried out after hydrotesting. 4. Hydrotesting date to be imprinted in every cylinders after hydrotest. 5. Certificate of PESO Approved testing agency to be submitted | 2 | EA |
| 5 | Replacement of Gas Cylinder Valve KIT (Including all types of Orings , Safety disc , NRV etc.) as approved by EIC. | 2 | EA |