- Home
- >
- Tender
- >
- Kerala Tender
- >
- Department of Indian Institute of Science Education and Research
- >
NTID 47276486
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowRectification Of The Eaton Mak in Thiruvananthapuram - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Rectification Of The Eaton Mak" in Thiruvananthapuram, India.
Indian Institute of Science Education and Research
Thiruvananthapuram, Kerala, India
NTID 47276486
- Opening Date : Fri 6th November, 2026
- Closing Date : Thu 5th November, 2026
- ₹ 169000.00
- NTID 47276486
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
3400.00 -
Document Cost
Refer Documents -
Estimated Cost
169000.00
BOQ Items Total Items : 3 | Total Qty : 3
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Rectification of the 4 loop and 2 loop addressable type Eaton make Cooper model Fire alarm panel installed in the Physical Science Block which includes panel trouble shooting, rectification of the faults, resolving false alarms, device location / loop verification, panel reprogramming, replacement of faulty fire alaram device etc. complete as required and as directed by Engineer in charge. Panel details: 1. Cooper 4 loop panel-CF3000 2. Cooper 2 loop panel-CF1200 Note: Supply of Fire alarm devices such as detectors, Manual Call points, Sounders etc.if required for replacment will be under the scope of IISER. | 1 | Each |
| 2 | Rectification of the 4 loop and 2 loop addressable type Eaton make Cooper model Fire alarm panel installed in the Biological Science Block which includes panel trouble shooting, rectification of the faults,resolving false alarms, device location / loop verification, panel reprogramming, replacement of faulty fire alaram device etc. complete as required and as directed by Engineer in charge. Panel details: 1. Cooper 4 loop panel-CF3000 2. Cooper 2 loop panel-CF1200 Note: Supply of Fire alarm devices such as detectors, Manual Call points, Sounders etc.if required for replacment will be under the scope of IISER. | 1 | Each |
| 3 | Replacement of the faulty display unit in the 2 loop Cooper Fire alarm panel in Physical Science Block with new display unit which includes dismanlting, procurment of LCD touch display for Cooper Fire alarm Panel-CF1200 and its installation, testing commissioning complete as required. | 1 | Each |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054