Tender for R N T Medical College and Controller Associated Group of Hospitals - NTID 29872910
R N T Medical College and Controller Associated Group of Hospitals
Udaipur, Rajasthan, India
NTID 29872910
- Opening Date : Wed 28th December, 2022
- Closing Date : Tue 27th December, 2022
- ₹ 100000000.00
- NTID 29872910
Rate Contract Of Cardiology Items - "radial Sheath With Puncture Needle For Adults (sizes 4 - 11 Fr.) – • Standard Length ; With Haemostatic Cross Cut Valve To Prevent Back Leak Of Blood And Aspiration Of Air; • With Integrated Side Arm With Attached 3-way Stopcock Snap-on/click-off Dilator Lock ; • With Suture Eye For Securing Sheath; • Kink Resistant; • With Dilator-hub Lock Mechanism To Prevent Its Back-out During Insertion; • Material Of Sheath Tubing Should Be Made Of Ptfe, Cross Cut Valve Should Be Made Up Of Silicon Rubber & Should Have Silicone Coating. Dilator Tube Should Be Made Up Of Polypropylene And Should Have Silicon Coating; Pack Must Include Surf Lash 20g*2 Entry Needle (plastic Iv Catheter)• Usfda/pmda Approved", "radial Sheath With Puncture Needle For Adults (sizes 4 - 11 Fr.) – • Standard Length ; With Haemostatic Cross Cut Valve To Prevent Back Leak Of Blood And Aspiration Of Air; • With Integrated Side Arm With Attached 3-way Stopcock Snap-on/click-off Dilator Lock ; • With Suture Eye For Securing Sheath; • Kink Resistant; • With Dilator-hub Lock Mechanism To Prevent Its Back-out During Insertion; • Material Of Sheath Tubing Should Be Made Of Ptfe, Cross Cut Valve Should Be Made Up Of Silicon Rubber & Should Have Silicone Coating. Dilator Tube Should Be Made Up Of Polypropylene And Should Have Silicon Coating; Pack Must Include Surf Lash 20g*2 Entry Needle (plastic Iv Catheter)• Ce - Approved", "radial Sheath With Puncture Needle For Adults (sizes 4 - 11 Fr.) – • Standard Length ; With Haemostatic Cross Cut Valve To Prevent Back Leak Of Blood And Aspiration Of Air; • With Integrated Side Arm With Attached 3-way Stopcock Snap-on/click-off Dilator Lock ; • With Suture Eye For Securing Sheath; • Kink Resistant; • With Dilator-hub Lock Mechanism To Prevent Its Back-out During Insertion; • Material Of Sheath Tubing Should Be Made Of Ptfe, Cross Cut Valve Should Be Made Up Of Silicon Rubber & Should Have Silicone Coating. Dilator Tube Should Be Made Up Of Polypropylene And Should Have Silicon Coating; Pack Must Include Surf Lash 20g*2 Entry Needle (plastic Iv Catheter)• Dcgi Approved", "radial Sheath:- 4 To 7 Fr• 0.21” Gw Compatible • Length 11 Cm• 21 G Needle• Removable Cap Which Has Hexacuspid Valve• Excellent Kink Resistant• Sideport Extension With 3-way Stopcock• Optimized Catheter Maneuverability With Minimal Leakage• Cannula Made Of Two Thinner Layers Of Polyethylene• Color Codes For Easy French Size Identification• Usfda/pmda Approved", "radial Sheath:- 4 To 7 Fr• 0.21” Gw Compatible • Length 11 Cm• 21 G Needle• Removable Cap Which Has Hexacuspid Valve• Excellent Kink Resistant• Sideport Extension With 3-way Stopcock• Optimized Catheter Maneuverability With Minimal Leakage• Cannula Made Of Two Thinner Layers Of Polyethylene• Color Codes For Easy French Size Identification• Ce- Approved", "radial Sheath:- 4 To 7 Fr• 0.21” Gw Compatible • Length 11 Cm• 21 G Needle• Removable Cap Which Has Hexacuspid Valve• Excellent Kink Resistant• Sideport Extension With 3-way Stopcock• Optimized Catheter Maneuverability With Minimal Leakage• Cannula Made Of Two Thinner Layers Of Polyethylene• Color Codes For Easy French Size Identification• Dcgi- Approved", "• Angiographic Catheter Comprised Of A Two-layer Construction Featuring Double Braided Stainless-steel Two-ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Diagnostic Catheter Comes With Anti-kinking Protector, With Non-braided Tip Shaft (distal -2 Cm) Offering Soft & Round Tip With Co-axial Alignment. • Comes With Transradial Catheter Shapes Designed To Cannulate Left And Right Coronary Arteries Eg: Tig, Tig Ii, Jacky, Sarah. Largest Inner Diameter Should Be Of Maximum 10 F Size• Usfda/pmda Approved", "• Angiographic Catheter Comprised Of A Two-layer Construction Featuring Double Braided Stainless-steel Two-ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Diagnostic Catheter Comes With Anti-kinking Protector, With Non-braided Tip Shaft (distal -2 Cm) Offering Soft & Round Tip With Co-axial Alignment. • Comes With Transradial Catheter Shapes Designed To Cannulate Left And Right Coronary Arteries Eg: Tig, Tig Ii, Jacky, Sarah. Largest Inner Diameter Should Be Of Maximum 10 F Size• Ce -approved", "• Angiographic Catheter Comprised Of A Two-layer Construction Featuring Double Braided Stainless-steel Two-ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Diagnostic Catheter Comes With Anti-kinking Protector, With Non-braided Tip Shaft (distal -2 Cm) Offering Soft & Round Tip With Co-axial Alignment. • Comes With Transradial Catheter Shapes Designed To Cannulate Left And Right Coronary Arteries Eg: Tig, Tig Ii, Jacky, Sarah. Largest Inner Diameter Should Be Of Maximum 10 F Size• Dcgi -approved", "dual Chamber Pacemaker (ddd) With Peel Away Sheath 6 Fr. • Screw In Or Tined Lead • Standard Warranty Of Minimum 10 Yrs.• Auto Capture Mode • Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism• Af Suppression • Optimization Of Av Delay • Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr.• Lead Should Be Compatible With 6 Fr. Peel Away Sheath• 1.5 T Mri Compatible (full Body)• Usfda/pmda Approved ", "dual Chamber Pacemaker (ddd) With Peel Away Sheath 6 Fr. • Screw In Or Tined Lead • Standard Warranty Of Minimum 10 Yrs.• Auto Capture Mode • Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism• Af Suppression • Optimization Of Av Delay • Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr.• Lead Should Be Compatible With 6 Fr. Peel Away Sheath• 1.5 T Mri Compatible (full Body)• Ce- Approved ", "dual Chamber Pacemaker (ddd) With Peel Away Sheath 6 Fr. • Screw In Or Tined Lead • Standard Warranty Of Minimum 10 Yrs.• Auto Capture Mode • Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism• Af Suppression • Optimization Of Av Delay • Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr.• Lead Should Be Compatible With 6 Fr. Peel Away Sheath• 1.5 T Mri Compatible (full Body)• Dcgi -approved ", "single Chamber Icd Set• Should Be Supplied With 7.0 To 7.6 Fr. Defibrillator Lead Should Be Compatible With 8 Fr. Peel Away Sheath • Small Size Below 35cc• Warranty : Minimum 8 Years• Heart Failure Congestion Monitoring Trends With Alerts• 40j Delivered Energy With Programmable Tilt And Pulse Width Programming• Facility Of Changing The Shocking Vector Based On Over Current Sensing• Special Sensing Filter Protection For T Wave Overspending• Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert• Facility Of Specially Coated Device For Avoiding Lead Abrasion• Proactive Measurement Of St Segment Changes With Alerts• Usfda/pmda Approved", "single Chamber Icd Set• Should Be Supplied With 7.0 To 7.6 Fr. Defibrillator Lead Should Be Compatible With 8 Fr. Peel Away Sheath • Small Size Below 35cc• Warranty : Minimum 8 Years• Heart Failure Congestion Monitoring Trends With Alerts• 40j Delivered Energy With Programmable Tilt And Pulse Width Programming• Facility Of Changing The Shocking Vector Based On Over Current Sensing• Special Sensing Filter Protection For T Wave Overspending• Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert• Facility Of Specially Coated Device For Avoiding Lead Abrasion• Proactive Measurement Of St Segment Changes With Alerts• Ce-approved", "single Chamber Icd Set• Should Be Supplied With 7.0 To 7.6 Fr. Defibrillator Lead Should Be Compatible With 8 Fr. Peel Away Sheath • Small Size Below 35cc• Warranty : Minimum 8 Years• Heart Failure Congestion Monitoring Trends With Alerts• 40j Delivered Energy With Programmable Tilt And Pulse Width Programming• Facility Of Changing The Shocking Vector Based On Over Current Sensing• Special Sensing Filter Protection For T Wave Overspending• Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert• Facility Of Specially Coated Device For Avoiding Lead Abrasion• Proactive Measurement Of St Segment Changes With Alerts• Dcgi-approved", "dual Chamber Icd Set• Should Be Supplied With 7.0 To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Lead Profile: Should Be Maximum Up To 5 .8 Fr. And Lead Should Be Compatible With 6 Fr. Peel Away Sheath• Small Size Below 35cc• Warranty : Minimum 8 Years• Heart Failure Congestion Monitoring Trends With Alerts• Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias• 40j Delivered Energy With Programmable Tilt And Pulse Width Programming.• Facility Of Changing The Shocking Vector Based On Over Current Sensing• Special Sensing Filter Protection For T Wave Over Sensing• Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert• Proactive Measurement Of St Segment Changes With Alerts• Facility Of Specially Coated Device For Avoiding Lead Abrasion (optional)• Usfda/pmda Approved", "dual Chamber Icd Set• Should Be Supplied With 7.0 To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Lead Profile: Should Be Maximum Up To 5 .8 Fr. And Lead Should Be Compatible With 6 Fr. Peel Away Sheath• Small Size Below 35cc• Warranty : Minimum 8 Years• Heart Failure Congestion Monitoring Trends With Alerts• Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias• 40j Delivered Energy With Programmable Tilt And Pulse Width Programming.• Facility Of Changing The Shocking Vector Based On Over Current Sensing• Special Sensing Filter Protection For T Wave Over Sensing• Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert• Proactive Measurement Of St Segment Changes With Alerts• Facility Of Specially Coated Device For Avoiding Lead Abrasion (optional)• Ce- Approved", "dual Chamber Icd Set• Should Be Supplied With 7.0 To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Lead Profile: Should Be Maximum Up To 5 .8 Fr. And Lead Should Be Compatible With 6 Fr. Peel Away Sheath• Small Size Below 35cc• Warranty : Minimum 8 Years• Heart Failure Congestion Monitoring Trends With Alerts• Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias• 40j Delivered Energy With Programmable Tilt And Pulse Width Programming.• Facility Of Changing The Shocking Vector Based On Over Current Sensing• Special Sensing Filter Protection For T Wave Over Sensing• Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert• Proactive Measurement Of St Segment Changes With Alerts• Facility Of Specially Coated Device For Avoiding Lead Abrasion (optional)• Dcgi - Approved", "cardiac Resynchronization Pacemaker With All Accessories - Ra, Rv And Bipolar Lv Leads And Catheters Crt-p• Lv Lead-upto 5 Fr. • Rv Lead Up To 5.8 Fr. And Compatible With 6 Fr. Sheath• Atrial Lead Up To 5.8 Fr. And Compatible With 6 Fr. Sheath• Heart Failure Congestion Monitoring Trends With Alerts• Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias• Electrocardiogram Based Av Optimization For Suggesting Optimized Av Delays• Warranty : Minimum 5 Years On Device• Special Algorithms To Predict Lead Failure And Protection Inappropriate Shocks During Failed Lead• Programmable At/af Alerts With Af Burden Trending• Facility Of Specially Coated Device For Avoiding Lead Abrasion (optional)• Special Trigger Mode Biventricular Pacing In Presence Of At/af• Facility Of Rf Telemetry• Should Be Supplied With 6 Compatible Leads And Introducers For Ra & Rv• Lv Lead Delivery Systems Should Be Compatible With 7 Fr. Ep Catheters Optional• Usfda /pmda Approved", "cardiac Resynchronization Pacemaker With All Accessories - Ra, Rv And Bipolar Lv Leads And Catheters Crt-p• Lv Lead-upto 5 Fr. • Rv Lead Up To 5.8 Fr. And Compatible With 6 Fr. Sheath• Atrial Lead Up To 5.8 Fr. And Compatible With 6 Fr. Sheath• Heart Failure Congestion Monitoring Trends With Alerts• Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias• Electrocardiogram Based Av Optimization For Suggesting Optimized Av Delays• Warranty : Minimum 5 Years On Device• Special Algorithms To Predict Lead Failure And Protection Inappropriate Shocks During Failed Lead• Programmable At/af Alerts With Af Burden Trending• Facility Of Specially Coated Device For Avoiding Lead Abrasion (optional)• Special Trigger Mode Biventricular Pacing In Presence Of At/af• Facility Of Rf Telemetry• Should Be Supplied With 6 Compatible Leads And Introducers For Ra & Rv• Lv Lead Delivery Systems Should Be Compatible With 7 Fr. Ep Catheters Optional• Ce - Approved", "cardiac Resynchronization Pacemaker With All Accessories - Ra, Rv And Bipolar Lv Leads And Catheters Crt-p• Lv Lead-upto 5 Fr. • Rv Lead Up To 5.8 Fr. And Compatible With 6 Fr. Sheath• Atrial Lead Up To 5.8 Fr. And Compatible With 6 Fr. Sheath• Heart Failure Congestion Monitoring Trends With Alerts• Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias• Electrocardiogram Based Av Optimization For Suggesting Optimized Av Delays• Warranty : Minimum 5 Years On Device• Special Algorithms To Predict Lead Failure And Protection Inappropriate Shocks During Failed Lead• Programmable At/af Alerts With Af Burden Trending• Facility Of Specially Coated Device For Avoiding Lead Abrasion (optional)• Special Trigger Mode Biventricular Pacing In Presence Of At/af• Facility Of Rf Telemetry• Should Be Supplied With 6 Compatible Leads And Introducers For Ra & Rv• Lv Lead Delivery Systems Should Be Compatible With 7 Fr. Ep Catheters Optional• Dcgi - Approved", "cardiac Resynchronization Defibrillator With With All Accessories - Ra, Rv And Bipolar Lv Leads And Catheters Crt-d• Lv Lead-upto 5 Fr. • Rv Defibrillator Lead : Should Be Supplied Up To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Lead Up To 5.8 Fr. And Compatible With 6 Fr. Sheath• 40j Delivered Energy• Pulse Width And Tilt : Programmable As Per Dft• Heart Failure Congestion Monitoring Trends With Alerts• Small Size Below 35cc• Warranty : Minimum 5 Years• Facility Of Changing The Shocking Vector Based On Over Current Sensing• Special Sensing Filter Protection For T Wave Over Sensing (optional)• Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Vibratory Patient Alert Optional• Facility Of Specially Coated Device For Avoiding Lead Abrasion (optional)• Usfda /pmda Approved", "cardiac Resynchronization Defibrillator With With All Accessories - Ra, Rv And Bipolar Lv Leads And Catheters Crt-d• Lv Lead-upto 5 Fr. • Rv Defibrillator Lead : Should Be Supplied Up To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Lead Up To 5.8 Fr. And Compatible With 6 Fr. Sheath• 40j Delivered Energy• Pulse Width And Tilt : Programmable As Per Dft• Heart Failure Congestion Monitoring Trends With Alerts• Small Size Below 35cc• Warranty : Minimum 5 Years• Facility Of Changing The Shocking Vector Based On Over Current Sensing• Special Sensing Filter Protection For T Wave Over Sensing (optional)• Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Vibratory Patient Alert Optional• Facility Of Specially Coated Device For Avoiding Lead Abrasion (optional)• Ce - Approved", "cardiac Resynchronization Defibrillator With With All Accessories - Ra, Rv And Bipolar Lv Leads And Catheters Crt-d• Lv Lead-upto 5 Fr. • Rv Defibrillator Lead : Should Be Supplied Up To 7.6 Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Lead Up To 5.8 Fr. And Compatible With 6 Fr. Sheath• 40j Delivered Energy• Pulse Width And Tilt : Programmable As Per Dft• Heart Failure Congestion Monitoring Trends With Alerts• Small Size Below 35cc• Warranty : Minimum 5 Years• Facility Of Changing The Shocking Vector Based On Over Current Sensing• Special Sensing Filter Protection For T Wave Over Sensing (optional)• Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Vibratory Patient Alert Optional• Facility Of Specially Coated Device For Avoiding Lead Abrasion (optional)• Dcgi - Approved", "pacemaker With His Bundle/left Bundle Pacing Algorithm As Single Chamber Pacemaker• Lead Profile Up To 6 Fr.• Usfda /pmda Approved ", "pacemaker With His Bundle/left Bundle Pacing Algorithm As Single Chamber Pacemaker• Lead Profile Up To 6 Fr. • Ce - Approved", "pacemaker With His Bundle/left Bundle Pacing Algorithm As Single Chamber Pacemaker• Lead Profile Up To 6 Fr.• Dcgi - Approved ", "pacemaker With His Bundle/left Bundle Pacing Algorithm As Double Chamber Pacemaker• Lead Profile Up To 6 Fr. • Usfda /pmda Approved", "pacemaker With His Bundle/left Bundle Pacing Algorithm As Double Chamber Pacemaker• Lead Profile Up To 6 Fr. • Ce - Approved", "pacemaker With His Bundle/left Bundle Pacing Algorithm As Double Chamber Pacemaker• Lead Profile Up To 6 Fr. • Dcgi - Approved", "pacemaker With His Bundle/left Bundle Pacing Algorithm As Crt-p • Lead Profile Up To 6 Fr. • Usfda/pmda Approved", "pacemaker With His Bundle/left Bundle Pacing Algorithm As Crt-p • Lead Profile Up To 6 Fr. • Ce - Approved", "pacemaker With His Bundle/left Bundle Pacing Algorithm As Crt-p • Lead Profile Up To 6 Fr. • Dcgi- Approved", "pacemaker With His Bundle/left Bundle Pacing Algorithm As Crt-d• Lead Profile Up To 6 Fr. • Usfda /pmda Approved", "pacemaker With His Bundle/left Bundle Pacing Algorithm As Crt-d• Lead Profile Up To 6 Fr. • Ce Approved", "pacemaker With His Bundle/left Bundle Pacing Algorithm As Crt-d• Lead Profile Up To 6 Fr. • Dcgi Approved", "pacemaker Lead With Peel Away Sheath Only (without Pulse Generator) For The Existing Company Providing Complete Pacemaker At Rnt Medical College • Usfda /pmda - Approved", "pacemaker Lead With Peel Away Sheath Only (without Pulse Generator) For The Existing Company Providing Complete Pacemaker At Rnt Medical College • Ce - Approved", "pacemaker Lead With Peel Away Sheath Only (without Pulse Generator) For The Existing Company Providing Complete Pacemaker At Rnt Medical College • Dcgi - Approved", "pacemaker (pg) Without Lead And Peel Away Sheath For The Existing Company Providing Complete Pacemaker At Rnt Medical College • Usfda /pmda Approved", "pacemaker (pg) Without Lead And Peel Away Sheath For The Existing Company Providing Complete Pacemaker At Rnt Medical College • Ce - Approved", "pacemaker (pg) Without Lead And Peel Away Sheath For The Existing Company Providing Complete Pacemaker At Rnt Medical College • Dcgi - Approved", "ptca Balloon (semi Compliant)with Entry Profile <0.016”, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 1.00 To 4.00 Mm And Lengths 8 Mm To 20 Mm• Core Wire Shaft For Better Push Ability• Usfda /pmda Approved", "ptca Balloon (semi Compliant)with Entry Profile <0.016”, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 1.00 To 4.00 Mm And Lengths 8 Mm To 20 Mm• Core Wire Shaft For Better Push Ability• Ce-approved", "ptca Balloon (semi Compliant)with Entry Profile <0.016”, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 1.00 To 4.00 Mm And Lengths 8 Mm To 20 Mm• Core Wire Shaft For Better Push Ability• Dcgi-approved", "ptca Balloon (non Compliant)with Entry Profile <0.016”, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 2.00 To 4.5 Mm And Lengths 5 Mm To 20 Mm• Core Wire Shaft For Better Push Ability• Usfda /pmda Approved", "ptca Balloon (non Compliant)with Entry Profile <0.016”, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 2.00 To 4.5 Mm And Lengths 5 Mm To 20 Mm• Core Wire Shaft For Better Push Ability• Ce-approved", "ptca Balloon (non Compliant)with Entry Profile <0.016”, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 2.00 To 4.5 Mm And Lengths 5 Mm To 20 Mm• Core Wire Shaft For Better Push Ability• Dcgi-approved", "special Valvuloplasty Balloon Catheter (tyshek Type) Usfda/ce Approved • Diameter 4 Mm To 35 Mm• Length 20 To 60 Mm• Nominal Pressure < 4 Atm• Should Have Dog Boning For Precise Position• Usfda /pmda Approved", "special Valvuloplasty Balloon Catheter (tyshek Type) Usfda/ce Approved • Diameter 4 Mm To 35 Mm• Length 20 To 60 Mm• Nominal Pressure < 4 Atm• Should Have Dog Boning For Precise Position• Ce - Approved", "special Valvuloplasty Balloon Catheter (tyshek Type) Usfda/ce Approved • Diameter 4 Mm To 35 Mm• Length 20 To 60 Mm• Nominal Pressure < 4 Atm• Should Have Dog Boning For Precise Position• Dcgi - Approved", "special Ptca Balloon Catheter Of Sizes 0.75 To 0.9 Mm- • Should Be Available In Variable Balloon Length 8-15 Mm• Usfda /pmda Approved", "special Ptca Balloon Catheter Of Sizes 0.75 To 0.9 Mm- • Should Be Available In Variable Balloon Length 8-15 Mm• Ce – Approved", "special Ptca Balloon Catheter Of Sizes 0.75 To 0.9 Mm- • Should Be Available In Variable Balloon Length 8-15 Mm• Dcgi - Approved", "special Ptca Balloon For Cto Penetration• Diameter Less Than 1 Mm • Length Less Than 9 Mm• Usfda /pmda Approved", "special Ptca Balloon For Cto Penetration• Diameter Less Than 1 Mm • Length Less Than 9 Mm• Ce - Approved", "special Ptca Balloon For Cto Penetration• Diameter Less Than 1 Mm • Length Less Than 9 Mm• Dcgi - Approved", "special Ptca Balloon Catheter Of Sizes 0.85 Mm Non Compliant Super High Pressure Balloon Dilatation Catheter Pressure From 23 Bar To 28 Bar Rbp Variable Large Mono Rail System, Hydrophilic Coated • Usfda /pmda Approved", "special Ptca Balloon Catheter Of Sizes 0.85 Mm Non Compliant Super High Pressure Balloon Dilatation Catheter Pressure From 23 Bar To 28 Bar Rbp Variable Large Mono Rail System, Hydrophilic Coated • Ce - Approved", "special Ptca Balloon Catheter Of Sizes 0.85 Mm Non Compliant Super High Pressure Balloon Dilatation Catheter Pressure From 23 Bar To 28 Bar Rbp Variable Large Mono Rail System, Hydrophilic Coated • Dcgi - Approved", "zerofold Ptca Balloon• Available In All Sizes And Length• Usfda /pmda Approved", "zerofold Ptca Balloon• Available In All Sizes And Length• Ce - Approved", "zerofold Ptca Balloon• Available In All Sizes And Length• Dcgi - Approved", "special Ptca Balloon For Cto-• Diameter Should Be 0.75 Mm Or Less• Usfda /pmda Approved", "special Ptca Balloon For Cto-• Diameter Should Be 0.75 Mm Or Less• Ce - Approved", "special Ptca Balloon For Cto-• Diameter Should Be 0.75 Mm Or Less• Dcgi - Approved", "ultra High Pressure Plaque Modification Device Dual Layer/rbp 35 Bars/abp Bars/abp 45 Bars Strictly Non-compliant (only10% Growth)/ And For Super High Pressure Ptcausfda /pmda Approve", "ultra High Pressure Plaque Modification Device Dual Layer/rbp 35 Bars/abp Bars/abp 45 Bars Strictly Non-compliant (only10% Growth)/ And For Super High Pressure Ptcace Approved", "ultra High Pressure Plaque Modification Device Dual Layer/rbp 35 Bars/abp Bars/abp 45 Bars Strictly Non-compliant (only10% Growth)/ And For Super High Pressure Ptcadcgi Approved", " Small Non-compliant Cto Balloon/diameter 0.85 M/ Lesion Entry Profile-0.016”/rbp-21 Atm/ Hydrophilic Coated/ Single Proximal Makerusfda /pmda Approved", " Small Non-compliant Cto Balloon/diameter 0.85 M/ Lesion Entry Profile-0.016”/rbp-21 Atm/ Hydrophilic Coated/ Single Proximal Makerce Approved", " Small Non-compliant Cto Balloon/diameter 0.85 M/ Lesion Entry Profile-0.016”/rbp-21 Atm/ Hydrophilic Coated/ Single Proximal Makerdcgi Approved", "semi Complaint Ptca Balloon With Smallest Entry Profile Of 0.585 Mm; Tapered Balloon Shape, Unique Tri-fold Wrapping Technology,tr2 Hydrophilic Coating, Available In Lowest Profile 1 Mm Diameterusfda /pmda Approved", "semi Complaint Ptca Balloon With Smallest Entry Profile Of 0.585 Mm; Tapered Balloon Shape, Unique Tri-fold Wrapping Technology,tr2 Hydrophilic Coating, Available In Lowest Profile 1 Mm Diameterce Approved", "semi Complaint Ptca Balloon With Smallest Entry Profile Of 0.585 Mm; Tapered Balloon Shape, Unique Tri-fold Wrapping Technology,tr2 Hydrophilic Coating, Available In Lowest Profile 1 Mm Diameterdcgi Approved", "non-compliant Ptca Balloon With Highest Rbp Up To 22 Atm; Tapered Balloon Tip To 4 Mm With Lowest Shoulder Angle To 32 Deg; Available In Lowest Profile 1.5 Mm Diameter Usfda /pmda Approved", "non-compliant Ptca Balloon With Highest Rbp Up To 22 Atm; Tapered Balloon Tip To 4 Mm With Lowest Shoulder Angle To 32 Deg; Available In Lowest Profile 1.5 Mm Diameter Ce Approved", "non-compliant Ptca Balloon With Highest Rbp Up To 22 Atm; Tapered Balloon Tip To 4 Mm With Lowest Shoulder Angle To 32 Deg; Available In Lowest Profile 1.5 Mm Diameter Dcgi Approved", "non Compliant –balloon With Nominal Pressure Of 12 Atm And Rbp Of 22 Atm .flexibal Thin Distal Tip With Low Entryprofile Of 0.43 Mm.innovative Triple Layer Ballon Technology For High Pressure Resistance (outer Layer Of Elastomer, Middle Layer Of Polyamide And Inner Most Layer Of Elastomer) To Provide Outstanding Flexibility And Crossing Performance. Usfda /pmda Approved", "non Compliant –balloon With Nominal Pressure Of 12 Atm And Rbp Of 22 Atm .flexibal Thin Distal Tip With Low Entryprofile Of 0.43 Mm.innovative Triple Layer Ballon Technology For High Pressure Resistance (outer Layer Of Elastomer, Middle Layer Of Polyamide And Inner Most Layer Of Elastomer) To Provide Outstanding Flexibility And Crossing Performance. Ce Approved", "non Compliant –balloon With Nominal Pressure Of 12 Atm And Rbp Of 22 Atm .flexibal Thin Distal Tip With Low Entryprofile Of 0.43 Mm.innovative Triple Layer Ballon Technology For High Pressure Resistance (outer Layer Of Elastomer, Middle Layer Of Polyamide And Inner Most Layer Of Elastomer) To Provide Outstanding Flexibility And Crossing Performance. Dcgi Approved", "ultra Low Entry Profile Of 0.016” With Hydrophilic Coating For Superior Crossability . Shorter And Thinner Radiopaque Maker For Lower Crossing Profile (length Of 0.8 Mm And Thickness Of 25 µm), Flexible Tip With Short Balloon Bonding Part Of 0.4 Mm. Robust And Improve Core Wire Shaft For Better Push Ability. Smallest Diameter Of 1.00 Mm And 5 Mm Length.usfda /pmda Approved", "ultra Low Entry Profile Of 0.016” With Hydrophilic Coating For Superior Crossability . Shorter And Thinner Radiopaque Maker For Lower Crossing Profile (length Of 0.8 Mm And Thickness Of 25 µm), Flexible Tip With Short Balloon Bonding Part Of 0.4 Mm. Robust And Improve Core Wire Shaft For Better Push Ability. Smallest Diameter Of 1.00 Mm And 5 Mm Length.ce Approved", "ultra Low Entry Profile Of 0.016” With Hydrophilic Coating For Superior Crossability . Shorter And Thinner Radiopaque Maker For Lower Crossing Profile (length Of 0.8 Mm And Thickness Of 25 µm), Flexible Tip With Short Balloon Bonding Part Of 0.4 Mm. Robust And Improve Core Wire Shaft For Better Push Ability. Smallest Diameter Of 1.00 Mm And 5 Mm Length.dcgi Approved", "non Compliant Ptca Balloon Dilatation Catheter• Tip Entry Profile < 0.016” (0.41 Mm) Ultra Low Tip Entry Profile • Shaft Diameter : Proximal < 1.95 F & Distal < 2.67 F• Guide Catheter – 5f Compatible• Balloon Material : Soft Multi Layered Polyamide• Balloon Fold Trifold (2-5mm)• Hydrophilic Coating : Selective Hydrophilic Coating At Distal Shaft Including Balloon Tip• Length : (mm) 6 To30• Diameter (mm) : 2 To 5.0• Nominal Pressure : 12 Atm• Rated Pressure Brust (rbp) – 20 Atm (18 Atm For 5 Mm)• Diameter Growth Between Nominal And Rated Brust Pressure Less Than 6%• Two Platinum – Iridium Marks • Shaft Length : > 140 Mm• Usfda /pmda Approved", "non Compliant Ptca Balloon Dilatation Catheter• Tip Entry Profile < 0.016” (0.41 Mm) Ultra Low Tip Entry Profile • Shaft Diameter : Proximal < 1.95 F & Distal < 2.67 F• Guide Catheter – 5f Compatible• Balloon Material : Soft Multi Layered Polyamide• Balloon Fold Trifold (2-5mm)• Hydrophilic Coating : Selective Hydrophilic Coating At Distal Shaft Including Balloon Tip• Length : (mm) 6 To 30• Diameter (mm) : 2 To 5.0• Nominal Pressure : 12 Atm• Rated Pressure Brust (rbp) – 20 Atm (18 Atm For 5 Mm)• Diameter Growth Between Nominal And Rated Brust Pressure Less Than 6%• Two Platinum – Iridium Marks • Shaft Length : > 140 Mm• Ce Approved", "non Compliant Ptca Balloon Dilatation Catheter• Tip Entry Profile < 0.016” (0.41 Mm) Ultra Low Tip Entry Profile • Shaft Diameter : Proximal < 1.95 F & Distal < 2.67 F• Guide Catheter – 5f Compatible• Balloon Material : Soft Multi Layered Polyamide• Balloon Fold Trifold (2-5mm)• Hydrophilic Coating : Selective Hydrophilic Coating At Distal Shaft Including Balloon Tip• Length : (mm) 6 To 30• Diameter (mm) : 2 To 5.0• Nominal Pressure : 12 Atm• Rated Pressure Brust (rbp) – 20 Atm (18 Atm For 5 Mm)• Diameter Growth Between Nominal And Rated Brust Pressure Less Than 6%• Two Platinum – Iridium Marks • Shaft Length : > 140 Mm• Dcgi Approved", "special Ptca Balloon For Cto Lesions Starting Diameter 0.85 Mm With Rbp 16 Atm Or Above. Balloon Hypotube Must Be Spiral-cut Design For Excellent Force Transmission From Proximal Shaft To Distal Tip. Quote Both Monorail (rapid Exchange) Or Otw Balloons.usfda /pmda Approved", "special Ptca Balloon For Cto Lesions Starting Diameter 0.85 Mm With Rbp 16 Atm Or Above. Balloon Hypotube Must Be Spiral-cut Design For Excellent Force Transmission From Proximal Shaft To Distal Tip. Quote Both Monorail (rapid Exchange) Or Otw Balloons.ce Approved", "special Ptca Balloon For Cto Lesions Starting Diameter 0.85 Mm With Rbp 16 Atm Or Above. Balloon Hypotube Must Be Spiral-cut Design For Excellent Force Transmission From Proximal Shaft To Distal Tip. Quote Both Monorail (rapid Exchange) Or Otw Balloons.dcgi Approved", "special Ptca Balloon ( Non-compliant) For Post Dilation. Must Have Diameter Starting From 1.75 Mm-5.0 Mm. Balloon Material Must Be Nylon For Controlled Compliance. Quote Both Monorail (rapid Exchange) Or Otw Balloons.usfda /pmda Approved", "special Ptca Balloon ( Non-compliant) For Post Dilation. Must Have Diameter Starting From 1.75 Mm-5.0 Mm. Balloon Material Must Be Nylon For Controlled Compliance. Quote Both Monorail (rapid Exchange) Or Otw Balloons.ce Approved", "special Ptca Balloon ( Non-compliant) For Post Dilation. Must Have Diameter Starting From 1.75 Mm-5.0 Mm. Balloon Material Must Be Nylon For Controlled Compliance. Quote Both Monorail (rapid Exchange) Or Otw Balloons.dcgi Approved", "high Pressure Non-compliant Ptca Balloon For Controlled Plaque, Expansion & Apposition. Balloon Must Available In Longest Length Up To 26 Mm. Should Have High Rbp Above 22 Atm. Quote Both Monorail (rapid Exchange) Or Otw Balloons.usfda /pmda Approved", "high Pressure Non-compliant Ptca Balloon For Controlled Plaque, Expansion & Apposition. Balloon Must Available In Longest Length Up To 26 Mm. Should Have High Rbp Above 22 Atm. Quote Both Monorail (rapid Exchange) Or Otw Balloons. Ce Approved.", "high Pressure Non-compliant Ptca Balloon For Controlled Plaque, Expansion & Apposition. Balloon Must Available In Longest Length Up To 26 Mm. Should Have High Rbp Above 22 Atm. Quote Both Monorail (rapid Exchange) Or Otw Balloons. Dcgi Approved.", "• Angiographic Double Lumen Tracking Catheter-- 4f/5f/6f For Various Purpose.• Usfda /pmda Approved", "• Angiographic Double Lumen Tracking Catheter-- 4f/5f/6f For Various Purpose.• Ce - Approved", "• Angiographic Double Lumen Tracking Catheter-- 4f/5f/6f For Various Purpose.• Dcgi - Approved", "special Ptca Guide Wire With Dual Coating Should Have Distal Hydrophilic Coating And Proximal Hydrophobic Coating.should Have Wires With Variable Tip Stiffness And Variable Shaft Support Tip Load <1gm• Usfda /pmda Approved", "special Ptca Guide Wire With Dual Coating Should Have Distal Hydrophilic Coating And Proximal Hydrophobic Coating.should Have Wires With Variable Tip Stiffness And Variable Shaft Support Tip Load <1gm• Ce- Approved", "special Ptca Guide Wire With Dual Coating Should Have Distal Hydrophilic Coating And Proximal Hydrophobic Coating.should Have Wires With Variable Tip Stiffness And Variable Shaft Support Tip Load <1gm• Dcgi- Approved", "heavy Duty Nitinol Alloy Extra Support Wire (regular Length And Exchange Length)- • 0.014 Inches , Nitinol Alloy , With Angled Tip -3-5 Cm Long• Tip With Platinum/platinum Alloy For Optimum Visualization• With Tfe Coating , 180 Cm To 300cm• Usfda /pmda Approved", "heavy Duty Nitinol Alloy Extra Support Wire (regular Length And Exchange Length)- • 0.014 Inches , Nitinol Alloy , With Angled Tip -3-5 Cm Long• Tip With Platinum/platinum Alloy For Optimum Visualization• With Tfe Coating , 180 Cm To 300cm• Ce - Approved", "heavy Duty Nitinol Alloy Extra Support Wire (regular Length And Exchange Length)- • 0.014 Inches , Nitinol Alloy , With Angled Tip -3-5 Cm Long• Tip With Platinum/platinum Alloy For Optimum Visualization• With Tfe Coating , 180 Cm To 300cm• Dcgi - Approved", "steerable High Support .014 Inch Guidewire (regular And Exchange Length)• Ptfe/ Duraglide Coated , • Distal Radio-opaque Tip 3 Cm Long• Straight And J Curve, 180 Cm To 300 Cm Long• Usfda /pmda Approved", "steerable High Support .014 Inch Guidewire (regular And Exchange Length)• Ptfe/ Duraglide Coated , • Distal Radio-opaque Tip 3 Cm Long • Straight And J Curve, 180 Cm To 300 Cm Long• Ce – Approved", "steerable High Support .014 Inch Guidewire (regular And Exchange Length)• Ptfe/ Duraglide Coated , • Distal Radio-opaque Tip 3 Cm Long • Straight And J Curve, 180 Cm To 300 Cm Long• Dcgi – Approved", "ptca Wires With Facility Of Boot Links For Extension Of Regular Wire - • Usfda /pmda Approved", "ptca Wires With Facility Of Boot Links For Extension Of Regular Wire - • Ce – Approved", "ptca Wires With Facility Of Boot Links For Extension Of Regular Wire - • Dcgi- Approved", "extensiion (doc) Wire For Approved Regular Length Ptca Guide Wires –• Usfda /pmda Approved", "extensiion (doc) Wire For Approved Regular Length Ptca Guide Wires –• Ce - Approved", "extensiion (doc) Wire For Approved Regular Length Ptca Guide Wires –• Dcgi - Approved", "penetration Catheters For Cto Having Rotational Blunt Penetration –• Usfda /pmda Approved", "penetration Catheters For Cto Having Rotational Blunt Penetration –• Ce - Approved", "penetration Catheters For Cto Having Rotational Blunt Penetration –• Dcgi - Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto –0.014"" One Piece Core Wire With Jointless Spring Coil 22cm Polymer Sleeve Length With Slip Coat Coating Over The Polymer Sleeve, Tip Load 1g And 0.8g,180cm Length, Tip Radiopacity 3cm• Usfda /pmda Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto –0.014"" One Piece Core Wire With Jointless Spring Coil 22cm Polymer Sleeve Length With Slip Coat Coating Over The Polymer Sleeve, Tip Load 1g And 0.8g,180cm Length, Tip Radiopacity 3cm• Ce - Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto –0.014"" One Piece Core Wire With Jointless Spring Coil 22cm Polymer Sleeve Length With Slip Coat Coating Over The Polymer Sleeve, Tip Load 1g And 0.8g,180cm Length, Tip Radiopacity 3cm• Dcgi - Approved", "specialized Ptca Guide Wire For Cto –stainless Steel Core Without Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 1.7 To 8.7 Gm.• Usfda /pmda Approved", "specialized Ptca Guide Wire For Cto –stainless Steel Core Without Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 1.7 To 8.7 Gm.• Ce - Approved", "specialized Ptca Guide Wire For Cto –stainless Steel Core Without Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 1.7 To 8.7 Gm.• Dcgi - Approved", "specialized Ptca Guide Wire For Cto –stainless Steel Core With Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 0.8 To 4.8 Gm.• Usfda /pmda Approved", "specialized Ptca Guide Wire For Cto –stainless Steel Core With Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 0.8 To 4.8 Gm.• Ce - Approved", "specialized Ptca Guide Wire For Cto –stainless Steel Core With Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 0.8 To 4.8 Gm.• Dcgi- Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto –0.014"" One Piece Core Wire With Jointless Spring Coil Ptfe Coating Over The Shaft ,tip Load 3g,4.5g,6gand 12g, 180cm Length With Tip Radiopacity 11cm• Usfda /pmda Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto –0.014"" One Piece Core Wire With Jointless Spring Coil Ptfe Coating Over The Shaft ,tip Load 3g,4.5g,6gand 12g, 180cm Length With Tip Radiopacity 11cm• Ce - Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto –0.014"" One Piece Core Wire With Jointless Spring Coil Ptfe Coating Over The Shaft ,tip Load 3g,4.5g,6gand 12g, 180cm Length With Tip Radiopacity 11cm• Dcgi – Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto –0.014"" One Piece Core Wire With Jointless Spring Coil And Slip Coat On The Spring Coil , Ptfe Coating Over The Shaft ,tip Load 3g, 180cm Length With Tip Radiopacity 11cm• Usfda /pmda Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto –0.014"" One Piece Core Wire With Jointless Spring Coil And Slip Coat On The Spring Coil , Ptfe Coating Over The Shaft ,tip Load 3g, 180cm Length With Tip Radiopacity 11cm• Ce - Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto –0.014"" One Piece Core Wire With Jointless Spring Coil And Slip Coat On The Spring Coil , Ptfe Coating Over The Shaft ,tip Load 3g, 180cm Length With Tip Radiopacity 11cm• Dcgi- Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto –non Hydrophilic Coated Tapered Tip .009"" With A Tip Load Of 9gm And Tip Radiopacity Of 20cm• Usfda /pmda Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto –non Hydrophilic Coated Tapered Tip .009"" With A Tip Load Of 9gm And Tip Radiopacity Of 20cm• Ce - Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto –non Hydrophilic Coated Tapered Tip .009"" With A Tip Load Of 9gm And Tip Radiopacity Of 20cm• Dcgi - Approved", "specialized Ptca Guidewire For Retrograde Approach & – Dedicated Guidewire For Externalization With Tip Load Of 3g, Length 330cm• Usfda /pmda Approved", "specialized Ptca Guidewire For Retrograde Approach & – Dedicated Guidewire For Externalization With Tip Load Of 3g, Length 330cm• Ce - Approved", "specialized Ptca Guidewire For Retrograde Approach & – Dedicated Guidewire For Externalization With Tip Load Of 3g, Length 330cm• Dcgi – Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto – One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Spring Coil Tapering To 0.009"" L, Tip Load 9g ,180cm Length, Tip Radiopacity 20cm• Usfda /pmda Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto – One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Spring Coil Tapering To 0.009"" L, Tip Load 9g ,180cm Length, Tip Radiopacity 20cm• Ce - Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto – One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Spring Coil Tapering To 0.009"" L, Tip Load 9g ,180cm Length, Tip Radiopacity 20cm• Dcgi - Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto –0.014"" One Piece Core Wire With Jointless Spring Coil, Ptfe Coating Over The Shaft, Tip Load .7g, 180cm Length With Tip Radiopacity 4cm• Usfda /pmda Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto –0.014"" One Piece Core Wire With Jointless Spring Coil, Ptfe Coating Over The Shaft, Tip Load .7g, 180cm Length With Tip Radiopacity 4cm• Ce - Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto –0.014"" One Piece Core Wire With Jointless Spring Coil, Ptfe Coating Over The Shaft, Tip Load .7g, 180cm Length With Tip Radiopacity 4cm• Dcgi - Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto –0.014"" One Piece Core Wire With Jointless Spring Coil Tapering To 0.009"" 16cm Polymer Sleeve Length With Slip Coat Coating Over The Polymer Sleeve,190cm Length Tip Radiopacity 16cm• Usfda /pmda Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto –0.014"" One Piece Core Wire With Jointless Spring Coil Tapering To 0.009"" 16cm Polymer Sleeve Length With Slip Coat Coating Over The Polymer Sleeve,190cm Length Tip Radiopacity 16cm• Ce - Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto –0.014"" One Piece Core Wire With Jointless Spring Coil Tapering To 0.009"" 16cm Polymer Sleeve Length With Slip Coat Coating Over The Polymer Sleeve,190cm Length Tip Radiopacity 16cm• Dcgi - Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto –ptca Guide Wire With Sion Tech Technology -tapered Type, Polymer Sleeve, Tipload 0.6-1.0g• Usfda /pmda Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto –ptca Guide Wire With Sion Tech Technology -tapered Type, Polymer Sleeve, Tipload 0.6-1.0g• Ce - Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto –ptca Guide Wire With Sion Tech Technology -tapered Type, Polymer Sleeve, Tipload 0.6-1.0g• Dcgi- Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto –0.010"" One Piece Core Wire With Joint Less Spring Coil With Sion Tech Technology Length 15cm , Cone Tip With A Tip Load Of 1.7gm, 3.5gm And 4.5gm, 190cm Length Tip Radiopacity 15cm, • Usfda /pmda Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto –0.010"" One Piece Core Wire With Joint Less Spring Coil With Sion Tech Technology Length 15cm , Cone Tip With A Tip Load Of 1.7gm, 3.5gm And 4.5gm, 190cm Length Tip Radiopacity 15cm, • Ce - Approved", "specialized Ptca Guide Wire For Retrograde Approach & Cto –0.010"" One Piece Core Wire With Joint Less Spring Coil With Sion Tech Technology Length 15cm , Cone Tip With A Tip Load Of 1.7gm, 3.5gm And 4.5gm, 190cm Length Tip Radiopacity 15cm, • Dcgi - Approved", "ptca Guide Wire-durasteel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 1.5 Gm To 4.1.gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity.• Usfda /pmda Approved", "ptca Guide Wire-durasteel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 1.5 Gm To 4.1.gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity.• Ce - Approved", "ptca Guide Wire-durasteel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 1.5 Gm To 4.1.gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity.• Dcgi - Approved", "workhorse Guide Wire With Dura Steel Core, Responses Core Grind Technology With Hydrophilic Coating And 1cm Uncoated Distal Tip For Tactile Feedback Available In Multiple Variants With Same Tip Load Of 0.9gm• Usfda /pmda Approved", "workhorse Guide Wire With Dura Steel Core, Responses Core Grind Technology With Hydrophilic Coating And 1cm Uncoated Distal Tip For Tactile Feedback Available In Multiple Variants With Same Tip Load Of 0.9gm• Ce - Approved", "workhorse Guide Wire With Dura Steel Core, Responses Core Grind Technology With Hydrophilic Coating And 1cm Uncoated Distal Tip For Tactile Feedback Available In Multiple Variants With Same Tip Load Of 0.9gm• Dcgi - Approved", "ptca Guide Wire-dura Steel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 0.8 Gm To 1.2 Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity.• Usfda /pmda Approved", "ptca Guide Wire-dura Steel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 0.8 Gm To 1.2 Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity.• Ce- Approved", "ptca Guide Wire-dura Steel Stainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket, Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 0.8 Gm To 1.2 Gm For Complex Anatomies, Hydrophilic Coating For Longer Lasting Lubricity.• Dcgi - Approved", "peripheral Wire 0.014-• Stainless Steel Core Wire• Hydrophilic & Hydrophobic Coating• Tip Load – 3 Gm & 6 Gm• Us Fda Approved• Wire Length- 190 Cm & 300 Cm• Usfda /pmda Approved", "peripheral Wire 0.014-• Stainless Steel Core Wire• Hydrophilic & Hydrophobic Coating• Tip Load – 3 Gm & 6 Gm• Us Fda Approved• Wire Length- 190 Cm & 300 Cm• Ce - Approved", "peripheral Wire 0.014-• Stainless Steel Core Wire• Hydrophilic & Hydrophobic Coating• Tip Load – 3 Gm & 6 Gm• Us Fda Approved• Wire Length- 190 Cm & 300 Cm• Dcgi - Approved", "peripheral Wire 0.018-• 0.018” Guide Wire With Stainless Steel Core Wire• Hydrophilic & Hydrophobic Coating• Tip Load – 7.6 Gm & 6.5 Gm• Us Fda Approved• Wire Length- 150 Cm, 200 & 300 Cm• Usfda /pmda Approved", "peripheral Wire 0.018-• 0.018” Guide Wire With Stainless Steel Core Wire• Hydrophilic & Hydrophobic Coating• Tip Load – 7.6 Gm & 6.5 Gm• Us Fda Approved• Wire Length- 150 Cm, 200 & 300 Cm• Ce - Approved", "peripheral Wire 0.018-• 0.018” Guide Wire With Stainless Steel Core Wire• Hydrophilic & Hydrophobic Coating• Tip Load – 7.6 Gm & 6.5 Gm• Us Fda Approved• Wire Length- 150 Cm, 200 & 300 Cm• Dcgi - Approved", "cto Wire 0.014”• 0.014” Weighted Tip Cto Guide Wire With Stainless Steel Core• Hydrophilic & Hydrophobic Coating• Tip Load- 12gm, 18 Gm, 25 Gm, 30 Gm• Wire Lengths-190 Cm & 300 Cm• Usfda /pmda Approved", "cto Wire 0.014”• 0.014” Weighted Tip Cto Guide Wire With Stainless Steel Core• Hydrophilic & Hydrophobic Coating• Tip Load- 12gm, 18 Gm, 25 Gm, 30 Gm• Wire Lengths-190 Cm & 300 Cm• Ce - Approved", "cto Wire 0.014”• 0.014” Weighted Tip Cto Guide Wire With Stainless Steel Core• Hydrophilic & Hydrophobic Coating• Tip Load- 12gm, 18 Gm, 25 Gm, 30 Gm• Wire Lengths-190 Cm & 300 Cm• Dcgi - Approved", "cto Wire 0.018”• 0.018” Weighted Tip Cto Guide Wire With Stainless Steel Core• Hydrophilic & Hydrophobic Coating• Tip Load- 12gm, 18 Gm, 25 Gm, 30 Gm• Usfda /pmda Approvedwire Lengths-190 Cm & 300 Cm", "cto Wire 0.018”• 0.018” Weighted Tip Cto Guide Wire With Stainless Steel Core• Hydrophilic & Hydrophobic Coating• Tip Load- 12gm, 18 Gm, 25 Gm, 30 Gm• Ce- Approvedwire Lengths-190 Cm & 300 Cm", "cto Wire 0.018”• 0.018” Weighted Tip Cto Guide Wire With Stainless Steel Core• Hydrophilic & Hydrophobic Coating• Tip Load- 12gm, 18 Gm, 25 Gm, 30 Gm• Dcgi- Approvedwire Lengths-190 Cm & 300 Cm", "peripheral Gw 0.035”• Moderate Rail Support• Length - 180-260 Cm• Tip - Spring Coil• Usfda /pmda Approved", "peripheral Gw 0.035”• Moderate Rail Support• Length - 180-260 Cm• Tip - Spring Coil• Ce- Approved ", "peripheral Gw 0.035”• Moderate Rail Support• Length - 180-260 Cm• Tip - Spring Coil• Dcgi - Approved", "peripheral Gw 0.035”• Extra Support Rail Strength• Length - 75-260 Cm• Tip - Spring Coil• Usfda /pmda Approved", "peripheral Gw 0.035”• Extra Support Rail Strength• Length - 75-260 Cm• Tip - Spring Coil• Ce- Approved", "peripheral Gw 0.035”• Extra Support Rail Strength• Length - 75-260 Cm• Tip - Spring Coil• Dcgi - Approved", "backup Meier Wire-0.035”• Should Have Extra Stiff Shaft To Support Aaa Device• Should Have Very Flexible And Soft Distal Tip To Avoid Aortic Perforation/vessel Trauma• Should Have Radiopaque Tip For Excellent Visibility, Ptfe Coated Proximal Shaft For Frictionless Advancement• Should Have Choice Of “j” And “c” Tip Shape With 182 Cm And 260/300 Cm• Usfda /pmda Approved", "backup Meier Wire-0.035”• Should Have Extra Stiff Shaft To Support Aaa Device• Should Have Very Flexible And Soft Distal Tip To Avoid Aortic Perforation/vessel Trauma• Should Have Radiopaque Tip For Excellent Visibility, Ptfe Coated Proximal Shaft For Frictionless Advancement• Should Have Choice Of “j” And “c” Tip Shape With 182 Cm And 260/300 Cm• Ce - Approved", "backup Meier Wire-0.035”• Should Have Extra Stiff Shaft To Support Aaa Device• Should Have Very Flexible And Soft Distal Tip To Avoid Aortic Perforation/vessel Trauma• Should Have Radiopaque Tip For Excellent Visibility, Ptfe Coated Proximal Shaft For Frictionless Advancement• Should Have Choice Of “j” And “c” Tip Shape With 182 Cm And 260/300 Cm• Dcgi - Approved", "hydrophilic Maker Wire-0.035”-• Should Have Single Piece Core With Radiopaque Polyurethane Jacket And Glidex Coated Hydrophilic Coating.• 4 Distal Platinum Magic Markers Spaced At 1 Cm For Improved Visualization• Single Piece Core Design To Have Better Steer Ability, Push Ability And Torque Transmission. • Usfda /pmda Approved", "hydrophilic Maker Wire-0.035”-• Should Have Single Piece Core With Radiopaque Polyurethane Jacket And Glidex Coated Hydrophilic Coating.• 4 Distal Platinum Magic Markers Spaced At 1 Cm For Improved Visualization• Single Piece Core Design To Have Better Steer Ability, Push Ability And Torque Transmission. • Ce- Approved", "hydrophilic Maker Wire-0.035”-• Should Have Single Piece Core With Radiopaque Polyurethane Jacket And Glidex Coated Hydrophilic Coating.• 4 Distal Platinum Magic Markers Spaced At 1 Cm For Improved Visualization• Single Piece Core Design To Have Better Steer Ability, Push Ability And Torque Transmission. • Dcgi - Approved", "balloons-nc Workhorse(0.035” Wire)• Should Be Non-compliant/ Semi Compliant. Rbp Of 20-24 Atm (3-8 Mm Balloon), 14-18 Atm (9-12 Mm Balloon)• Should Have High Rated Burst Pressure With Scratch/puncture Resistant Pebax Material• Dual Lumen Shaft With Balloon Laser Bonded And Short Atraumatic Tapered Tip• Should Have Lubricious Medi –glide Coating And Balloon Material• Should Have Good Re-wrape And Low Tip Profile• Should Be 5f (3-7 Mm Balloon) /6f(8-10 Mm Balloon/7f (12 Mm Balloon) Sheath And 0.035” Wire Compatible• Should Have Min Lesion Entry Profile Of 0.040” (1.016 Mm)• Should Have Choice Of Long Balloon Length 20 Mm To 200 Mm• Usfda /pmda Approved", "balloons-nc Workhorse(0.035” Wire)• Should Be Non-compliant/ Semi Compliant. Rbp Of 20-24 Atm (3-8 Mm Balloon), 14-18 Atm (9-12 Mm Balloon)• Should Have High Rated Burst Pressure With Scratch/puncture Resistant Pebax Material• Dual Lumen Shaft With Balloon Laser Bonded And Short Atraumatic Tapered Tip• Should Have Lubricious Medi –glide Coating And Balloon Material• Should Have Good Re-wrape And Low Tip Profile• Should Be 5f (3-7 Mm Balloon) /6f(8-10 Mm Balloon/7f (12 Mm Balloon) Sheath And 0.035” Wire Compatible• Should Have Min Lesion Entry Profile Of 0.040” (1.016 Mm)• Should Have Choice Of Long Balloon Length 20 Mm To 200 Mm• Ce - Approved", "balloons-nc Workhorse(0.035” Wire)• Should Be Non-compliant/ Semi Compliant. Rbp Of 20-24 Atm (3-8 Mm Balloon), 14-18 Atm (9-12 Mm Balloon)• Should Have High Rated Burst Pressure With Scratch/puncture Resistant Pebax Material• Dual Lumen Shaft With Balloon Laser Bonded And Short Atraumatic Tapered Tip• Should Have Lubricious Medi –glide Coating And Balloon Material• Should Have Good Re-wrape And Low Tip Profile• Should Be 5f (3-7 Mm Balloon) /6f(8-10 Mm Balloon/7f (12 Mm Balloon) Sheath And 0.035” Wire Compatible• Should Have Min Lesion Entry Profile Of 0.040” (1.016 Mm)• Should Have Choice Of Long Balloon Length 20 Mm To 200 Mm• Dcgi - Approved", "balloons -0.018”/0.014” Wire Compatible –• Should Be 4f/5f Sheath And 0.018”/0.014” Wire Compatible With Choice Of Otw/monorail Delivery System• Should Be Non-compliant/ Semi Compliant.• Should Have High Rated Burst Pressure With Scratch/puncture Resistant Pebax Material• Should Have Lowest Tip Entry Profile Of Not More Than 0.022” And Good 5 Fold Re-wrap Design• Should Have Excellent Coulum Support With Balloon Laser Bonded And Short Atraumatic Tapered Tip• Should Have Full Length Tapered Core Wire For Enhancd Pushability And Kink Resistance• Should Have Balloon Length Starting From 10 Mm And Balloon Diameter From 3 Mm To 10 Mm. • Usfda /pmda Approved", "balloons -0.018”/0.014” Wire Compatible –• Should Be 4f/5f Sheath And 0.018”/0.014” Wire Compatible With Choice Of Otw/monorail Delivery System• Should Be Non-compliant/ Semi Compliant.• Should Have High Rated Burst Pressure With Scratch/puncture Resistant Pebax Material• Should Have Lowest Tip Entry Profile Of Not More Than 0.022” And Good 5 Fold Re-wrap Design• Should Have Excellent Coulum Support With Balloon Laser Bonded And Short Atraumatic Tapered Tip• Should Have Full Length Tapered Core Wire For Enhancd Pushability And Kink Resistance• Should Have Balloon Length Starting From 10 Mm And Balloon Diameter From 3 Mm To 10 Mm. • Ce - Approved", "balloons -0.018”/0.014” Wire Compatible –• Should Be 4f/5f Sheath And 0.018”/0.014” Wire Compatible With Choice Of Otw/monorail Delivery System• Should Be Non-compliant/ Semi Compliant.• Should Have High Rated Burst Pressure With Scratch/puncture Resistant Pebax Material• Should Have Lowest Tip Entry Profile Of Not More Than 0.022” And Good 5 Fold Re-wrap Design• Should Have Excellent Coulum Support With Balloon Laser Bonded And Short Atraumatic Tapered Tip• Should Have Full Length Tapered Core Wire For Enhancd Pushability And Kink Resistance• Should Have Balloon Length Starting From 10 Mm And Balloon Diameter From 3 Mm To 10 Mm. • Dcgi - Approved", "distal Embolic Protection Device-carotid/svg-• (one Size For All Carotids)• Eccentric Filter With Nitinol Loop For 360 Degree Wall Apposition• Rx.014 6f Sheath Compatible • 190 Cm Extra Support Wire • Uniform Micro Pore Size Of 110 Micron Pore Size With 1 Mm Pore Free Zone• Non Thrombogenic Nylon Membrane With Hydrophilic Coating• Shouls Allow Optimal Filtration In Vessels 3-5.5 Mm Sizeusfda /pmda Approved", "distal Embolic Protection Device-carotid/svg-• (one Size For All Carotids)• Eccentric Filter With Nitinol Loop For 360 Degree Wall Apposition• Rx.014 6f Sheath Compatible • 190 Cm Extra Support Wire • Uniform Micro Pore Size Of 110 Micron Pore Size With 1 Mm Pore Free Zone• Non Thrombogenic Nylon Membrane With Hydrophilic Coating• Shouls Allow Optimal Filtration In Vessels 3-5.5 Mm Size• Ce- Approved", "distal Embolic Protection Device-carotid/svg-• (one Size For All Carotids)• Eccentric Filter With Nitinol Loop For 360 Degree Wall Apposition• Rx.014 6f Sheath Compatible • 190 Cm Extra Support Wire • Uniform Micro Pore Size Of 110 Micron Pore Size With 1 Mm Pore Free Zone• Non Thrombogenic Nylon Membrane With Hydrophilic Coating• Shouls Allow Optimal Filtration In Vessels 3-5.5 Mm Size• Dcgi- Approved", "balloon Expandable Stent-renal (small Diameter)-• Should Be Low Profile, 6f Guide And 0.014” Wire Compatible, Monorail System• Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity• Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability• Should Have Increased Support And Radial Strength And Proximal End For Ostial Lesion• Stent Should Be Premounted On Semicompliant Balloon Catheter • Stent Dia 4-7 Mm, Length 15 & 19, Catheter Length 90 & 150 Cm.• Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon.• Usfda /pmda Approved", "balloon Expandable Stent-renal (small Diameter)-• Should Be Low Profile, 6f Guide And 0.014” Wire Compatible, Monorail System• Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity• Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability• Should Have Increased Support And Radial Strength And Proximal End For Ostial Lesion• Stent Should Be Premounted On Semicompliant Balloon Catheter • Stent Dia 4-7 Mm, Length 15 & 19, Catheter Length 90 & 150 Cm.• Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon.• Ce - Approved", "balloon Expandable Stent-renal (small Diameter)-• Should Be Low Profile, 6f Guide And 0.014” Wire Compatible, Monorail System• Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity• Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability• Should Have Increased Support And Radial Strength And Proximal End For Ostial Lesion• Stent Should Be Premounted On Semicompliant Balloon Catheter • Stent Dia 4-7 Mm, Length 15 & 19, Catheter Length 90 & 150 Cm.• Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon.• Dcgi - Approved", "balloon Expandable Stent- Large Diameter-• Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity• Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability• Should Have Low Foreshortening, Low Recoil.• Stent Should Be Premounted On Non Compliant Balloon Catheter To Avoid Dogboning And Proper Scaffolding• Should Have Dual Lumen Catheter Design For Faster Deflation• Stent Dia 5-10 Mm, Length 27,37,57, Catheter Length 135 Cm.• Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon.• Usfda /pmda Approved", "balloon Expandable Stent- Large Diameter-• Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity• Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability• Should Have Low Foreshortening, Low Recoil.• Stent Should Be Premounted On Non Compliant Balloon Catheter To Avoid Dogboning And Proper Scaffolding• Should Have Dual Lumen Catheter Design For Faster Deflation• Stent Dia 5-10 Mm, Length 27,37,57, Catheter Length 135 Cm.• Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon.• Ce - Approved", "balloon Expandable Stent- Large Diameter-• Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity• Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability• Should Have Low Foreshortening, Low Recoil.• Stent Should Be Premounted On Non Compliant Balloon Catheter To Avoid Dogboning And Proper Scaffolding• Should Have Dual Lumen Catheter Design For Faster Deflation• Stent Dia 5-10 Mm, Length 27,37,57, Catheter Length 135 Cm.• Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon.• Dcgi - Approved", "self Expandable Stent For Carotid Artery Stenting-• Self Expending Elgilloy Stent With Closed Cell Design/ Auto Tapered Design.• Monorail, 0.014” Wire & 6f Sheath Compatible• Recons Trainable Braided Stent• Shaft Length 135 Cm• Dia-6-9 Mm• Usfda /pmda Approved", "self Expandable Stent For Carotid Artery Stenting-• Self Expending Elgilloy Stent With Closed Cell Design/ Auto Tapered Design.• Monorail, 0.014” Wire & 6f Sheath Compatible• Recons Trainable Braided Stent• Shaft Length 135 Cm• Dia-6-9 Mm• Ce - Approved", "self Expandable Stent For Carotid Artery Stenting-• Self Expending Elgilloy Stent With Closed Cell Design/ Auto Tapered Design.• Monorail, 0.014” Wire & 6f Sheath Compatible• Recons Trainable Braided Stent• Shaft Length 135 Cm• Dia-6-9 Mm• Dcgi - Approved", "self Expandable Stent-• Should Be Laser Cut Self Expending Nitinol Stent With Proximal End Distal Makers• Should Have Hybrid Cell Design Which Promotes A Balance Of Radial Strength And Flexibility.• Should Have Controlled Release/deployment Mechanism To Ensure Precise Placement And Low Foreshortening.• Should Be 6f Sheath And 0.035” Wire Compatible Across Sent Size Matrix.• Usfda /pmda Approved", "self Expandable Stent-• Should Be Laser Cut Self Expending Nitinol Stent With Proximal End Distal Makers• Should Have Hybrid Cell Design Which Promotes A Balance Of Radial Strength And Flexibility.• Should Have Controlled Release/deployment Mechanism To Ensure Precise Placement And Low Foreshortening.• Should Be 6f Sheath And 0.035” Wire Compatible Across Sent Size Matrix.• Ce - Approved", "self Expandable Stent-• Should Be Laser Cut Self Expending Nitinol Stent With Proximal End Distal Makers• Should Have Hybrid Cell Design Which Promotes A Balance Of Radial Strength And Flexibility.• Should Have Controlled Release/deployment Mechanism To Ensure Precise Placement And Low Foreshortening.• Should Be 6f Sheath And 0.035” Wire Compatible Across Sent Size Matrix.• Dcgi - Approved", "peripheral Self Expanding Drug Eluting Stent-• Paclitaxel Eluting Self-expanding Stent With A Polymer That Releases Paclitaxel Over 12 Month With Lowest Dose Density Of 0.167ug/mm2 For Sfa And Ppa• Triaxial Delivery System• Hybrid Cell Architecture With Open And Close Celldesisn• Easy Deployment With Thumbwheel & Pull Grip• 6f Sheath Compatibility• Dia-6 &10 Mm• Length – 40,60,80,100,120 Mm• Usfda /pmda Approved", "peripheral Self Expanding Drug Eluting Stent-• Paclitaxel Eluting Self-expanding Stent With A Polymer That Releases Paclitaxel Over 12 Month With Lowest Dose Density Of 0.167ug/mm2 For Sfa And Ppa• Triaxial Delivery System• Hybrid Cell Architecture With Open And Close Celldesisn• Easy Deployment With Thumbwheel & Pull Grip• 6f Sheath Compatibility• Dia-6 &10 Mm• Length – 40,60,80,100,120 Mm• Ce Approved", "peripheral Self Expanding Drug Eluting Stent-• Paclitaxel Eluting Self-expanding Stent With A Polymer That Releases Paclitaxel Over 12 Month With Lowest Dose Density Of 0.167ug/mm2 For Sfa And Ppa• Triaxial Delivery System• Hybrid Cell Architecture With Open And Close Celldesisn• Easy Deployment With Thumbwheel & Pull Grip• 6f Sheath Compatibility• Dia-6 &10 Mm• Length – 40,60,80,100,120 Mm• Dcgi- Approved", "peripheral Self Expanding Stent Sfa-• Easy Development With Thumbwheel & Pull Grip• 6f Sheath Compatibility• Dia- 5,6,7,8 Mm• Length – 40,60,80,100,120,150 Mm• Usfda /pmda Approved", "peripheral Self Expanding Stent Sfa-• Easy Development With Thumbwheel & Pull Grip• 6f Sheath Compatibility• Dia- 5,6,7,8 Mm• Length – 40,60,80,100,120,150 Mm• Ce- Approved", "peripheral Self Expanding Stent Sfa-• Easy Development With Thumbwheel & Pull Grip• 6f Sheath Compatibility• Dia- 5,6,7,8 Mm• Length – 40,60,80,100,120,150 Mm• Dcgi- Approved", "pva Particles-• Should Be Made Of Polyvinyalcohol• Should Have Uniquely Shaped And Consistent Sized Particles.• Usfda /pmda Approved", "pva Particles-• Should Be Made Of Polyvinyalcohol• Should Have Uniquely Shaped And Consistent Sized Particles.• Ce - Approved", "pva Particles-• Should Be Made Of Polyvinyalcohol• Should Have Uniquely Shaped And Consistent Sized Particles.• Dcgi - Approved", "asd Closure Devices With Delivery System • Approved For Pediatric/adult Use• Device Made Of Biologically Inert Material• Self-centering, Detachable Device With Delivery • Cable• Polyester Fabric Integrated In Each Disc. • Chemically Treated To Improve Biocompatibility & Reduce Nickel (ni) Leaching.• Mr. Conditional Up To 3 Tesla • Available In All The Sizes (6 Mm – 40 Mm)• Usfda /pmda Approved", "asd Closure Devices With Delivery System • Approved For Pediatric/adult Use• Device Made Of Biologically Inert Material• Self-centering, Detachable
Documents
Unlock the opportunities
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
2000000.00 -
Document Cost
1000.00 -
Estimated Cost
100000000.00
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane