- Home
- >
- Tender
- >
- Maharashtra Tender
- >
- Department of Pimpri Chinchwad Municipal Corporation
- >
NTID 47246142
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowRate Analysis Of Annual Compre in Pune - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Rate Analysis Of Annual Compre" in Pune, India.
Pimpri Chinchwad Municipal Corporation
Pune, Maharashtra, India
NTID 47246142
- Opening Date : Thu 5th November, 2026
- Closing Date : Wed 4th November, 2026
- ₹ 0.00
- NTID 47246142
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
Refer Documents -
Document Cost
Refer Documents -
Estimated Cost
Refer Documents
BOQ Items Total Items : 1 | Total Qty : 1
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Comprehensive Annual Maintenance Contract (AMC) for 24×7 Operation, Preventive Maintenance, Breakdown Maintenance and Repair of Electrical Installations and Electrical Equipment at Eye Hospital, Ajmera ,Masulkar colony including Hospital Building, Parking Area and Campus. Scope of Work- The contractor shall carry out 24×7 comprehensive operation and maintenance of the complete electrical installation of the hospital, including all electrical wiring, lighting systems, fans, exhaust fans, wall fans, LED lights, tube lights, round lights, switch boards, distribution boards, water coolers, water purifiers and other electrical equipment installed in the hospital premises. The scope shall include the following (Approximate Electrical Equipment Inventory of All Electrical Equipment to be maintained & if required to be replaced). 18W Down Light-161 Nos, Celling fan-43Nos, 2 x 2 LED Light36W- 257 Nos, Exhaust Fan-49Nos, Stand Fan-48 Nos, 20W Tube Light-141Nos, Wall fan -10 Nos, Water Cooler -2 Nos, Water Purifier-11Nos. Panel Details are as follows:- • Electrical Room :- Main Breaker panel room-ACB:-1600 Amp (2 Qty), ACB:-1250 Amp (2 Qty ),ACB:-1000 Amp (1 Qty)MCCB 63 Amps( 5 Qty), 160Amp( 2qty),250 Amp( 2Qty), 630 Amp ( 2 Qty),20 Amp( 1 Qty).Power factor panel-ACB 1000A(1No). Street light –MCB -3 pole63A(1No), MCB -4 pole32A(1No), MCB32A(4No), • Ground Floor:-Total Qty- ACB-1250A(1No), MCCB of ratings 100Amp(6 Qty), 125A(4No), 400A(2 Nos), 63A(11 NOS), 630A(3Qty ). MCCB 4 POLE 32 A(3QTY) 63A(5 NOS).DISTRIBUTION BOX-.40A-4POLE-3NOS, 16A-1POLE-25NOS, 10A-51NOS, 20A-1 POLE-1NOS, 32A-1POLE-2 NOS.CANTEEN MCB 4 POLE 63A(1NO), MCB 20A(8NOS), SECURITY CABIN MCB 4 POLE 63A(1NO). MCB 2 POLE,32A(1NO) • First Floor :- MCCB of ratings 400 Amp (1 Qty), 160A(3Nos), 100A(4Nos), MCB 4 pole 63A(11Nos), 32 Amp(1 Qty). UPS-1- MCCB 400A(1No),250A(1No),Breaker 250A (3Nos) 40A-4POLE-4NOS, 80A-4POLE-1NOS, 32A-1POLE-6 NO, 32A-2POLE-1 NOS , 25A-2POLE-2 NOS, 16A-2POLE-4 NOS, 16A-1POLE-2 8NOS, 20A-1POLE-11 NOS, 10A-1POLE-5NOS., • Second Floor :- UPS -2-MCCB of rating 250 Amp(1 Qty), MCB 63Amp (8 Qty), 40A-4POLE-3NOS, 63A-4POLE-5NOS, 32A-4POLE-1NOS, 32A-2POLE-1NO, 25A-2POLE-2NOS, 20A-1POLE-27NOS, , 32A-1POLE-2NO, 16A-1POLE-4NO, 10A-1POLE-32NO, 25A-1POLE-3 NO, • TERRACE PANEL-MCCB 630A-1NO., -MCCB 63A-8NO., -LCB 300MA-7NO., -MCB 40A-1NO., MCB 32A-2NO., MCB 25A-1NO., LCB 40A-2NO • DG Panel :- ACB of rating 800 Amp (1Qty) UPS Details :- • 100 kVA (2 Qty), 5kVA ( 1 Qty), Pump Details are as follows ;- Water load pump-Three Phase Monblock 3 HP (4 Qty). Borewell pump , Out going cable from main panel to DBs., All panel Handles, Locks, , Earthing of Elect installations,etc. Above mentioned panel details and all Distribution Boards at Masulkar Eye Hospital is to be covered under this Comprehensive Maintenance schedule. 1. The contractor shall provide qualified/skilled electricians, semi-skilled electricians and reliever manpower for three Shift operation on 24×7 basis for operation and maintenance of the Masulkar Eyei Hospital electrical installation. 2 Electrician ITI & 2 Helper per shift 2. The contractor shall provide adequate manpower in all three shifts so that electrical services are maintained continuously throughout the day and night. Duty chart of appointed staff by the contractor should be submitted by the contractor to Engineer In Charge at start of every month. Also the appointed staff shal take daily Testing of DG and report its Diesel level, daily take reading of HT metering and maintain its daily register, maintain hourly logsheet readings from LT Panel 3. The contractor shall attend to all major and minor electrical faults/ Electrical wiring Problem immediately upon receipt of the complaint. Maintain History register. 4. The contractor shall carry out preventive maintenance, routine maintenance, breakdown maintenance and corrective maintenance of all electrical installations. 5. Defective electrical components, accessories, switches, sockets, MCBs, wiring accessories, lighting fixtures and other electrical parts shall be inspected and replaced/repaired as required, as per the terms of the AMC. As per instructions of Engineer in charge. 6. The contractor shall maintain/repair/replace all electrical wiring, switch boards, distribution boards, lighting points, fans, area lights, exhaust fans, LED lights, tube lights, and the above mentioned other electrical installations At Masulkar Eye Hospital including all ICU, NICU, operation theaters maintenance. 7. The contractor shall carry out major and minor electrical repair works through qualified technical personnel and ensure immediate restoration of the healthy electrical system. 8. In case of failure/interruption of MSEDCL power supply, the contractor shall immediately register the complaint with MSEDCL and continuously take follow up with MSEDCL until restoration of the power supply. 9. The contractor shall maintain a complaint register/breakdown register and record the time of complaint, nature of fault, action taken and time of restoration. 10. Regular inspection and preventive maintenance shall be carried out to avoid electrical failures and ensure uninterrupted electrical supply to critical hospital areas. 11. All electrical works shall be carried out strictly as per applicable electrical safety rules, standards and instructions of Engineer In Charge. 12. The contractor shall provide necessary tools, testing instruments, safety equipment and other accessories required for routine and breakdown maintenance for the staff appointed by the contractor. 13. The contractor shall attend emergency electrical complaints at any time, including Sundays and public holidays. 14. The contractor shall ensure uninterrupted operation and maintenance of the electrical installation throughout the AMC period. Note: The above quantities and other electrical work are based on the details provided and shall be verified through a joint physical site survey/inventory before finalization of the estimate | 1 | per year |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054