- Home
- >
- Tender
- >
- Jharkhand Tender
- >
- Department of Military Engineer Services
- >
NTID 44471194
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowCorrigendum Provn Of Infra F in Ranchi - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Corrigendum Provn Of Infra F" in Ranchi, India.
- Opening Date : Sat 18th April, 2026
- Closing Date : Sat 11th April, 2026
- ₹ 3280000.00
- NTID 44471194
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
65600.00 -
Document Cost
500.00 -
Estimated Cost
3280000.00
Latest Corrigendum List
| # | Corrigendum Title | Corrigendum Type |
|---|---|---|
| 1 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum |
BOQ Items Total Items : 32 | Total Qty : 1449.3
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | M&L for provision of transformer plinth of size 2.5 x 2.5 mtrs and 1.5 mtr above ground level complete with fencing by using MS angle posts, GI pipes, chain link fencing and barbed wire with safety standard IS 3034, IS 875 and PCC foundation, RCC Slab and gravel filling all around all as shown TD-251 Sheet 1/1 complete all as specified and directed. | 1.00 | Each Job |
| 2 | Supply , installing, testing and commissioning of outdoor type step down transformer 11000/433 volts (at no load), AC , 3 phase 50 Hz , copper wound type complete with standard fittings, 11 KV 3 phase , LT 433 volts, 3 phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS: 1180 (with latest amendments) of capactiy 315 KVA. of level 3 ,core type copper wound,oil immersed, naturally cooled, oil nature,air nature(ONAN) with external cooling tubes/fins delta connected on primary side (HV) and star connected on secondary side(LV) in accordance with vector symbol DYN-11(Vector group)with neutral brought out on secondary side (LV side ) and having tapping upto 7.5% HV side in step of 2.5% to be changed by means of hand operated off load tap changer gear. the maximum temparature rise should not exceed 45 degree celsius in oil and 55 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temparature of 40 degree celsius. The transformer shall be IS 1180 marked and shall comprise of the following :- (a) 3 Nos porcelain bushing with arcing horn on HV side suitable for 11 KV complete with bushing,copper rods, nut and washers. (b) One cable box on LT side (secondary side ) consisting of 04 No of porcelain bushing with copper rod , complete with nuts and washers with two numbers cable glands suitable for reception /taking out of XLPE insulated heavy duty armoured cable including glands, joints and jointing material complete. (c) Oil conservator with filter type drain valve and oil level gauge (d) Dehydrating breather with first fills dehydrating agents (silca gel) (e) Thermometer pocket on tank cover (f) One number 100 mm dia, dial type thermometer, vapour pressure type having range 0-120 degree celsious wth metal guard having max perimeter reading tempreture indicator with resisting device for transformer (g) Two earthing terminal on tank cover to facilitate fixing of 32x6 mm GI earth strip for earhting of neutral and body. | 1.00 | Each |
| 3 | (h) Rating plate and terminal marking plate (i) Oil level gauge (j) Oil drain filter valve (k) Lifting legs (l) Oil filling holes with cap/plug with connecting plate complete (m) Air release plug (n) Four plain solid cost steel detachable rollers (o) Extra bushing for neutral, outside LT cable box for proving independent earthig for neutral (p) First filling new and unused transformer oil IS-335/93(forth version) marked (make -HP/power oil or equivalent as approved by GE) filtered and tested dielectric strength at 2.5 mm air gap between testing electrode asper IS 335. Note: Certification of electric strength shall be submitted by the cotractor after filling the oil | ||
| 4 | Supply, fixing, testing and commissioning air break isolating switch tripple pole mechanically operated with vertical isolation,9 nos. polymer type insulators mounted on steel frame with operating mechanism worked from ground level and including operating rod of 25 mm dia medium grade GI pipe and locking arrangement of capacity 200 Amps 11 KV with drop out fuse set including making all incoming/outgoing connection of HT cable and overhead conductor using new leads and nuts, bolts etc and painting of steel work with 2 coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. | 1 | Each |
| 5 | M&L for cross arms, bracing supports, clamps back plates angles fabricated from the structural steel section including bolts, nuts, washers, welding, bending, drilling holes for bolts, bent to any required shape of size as indicated or directed, inclusive of one primer coat and two coats of aluminium paint after preparation of surfaces complete all as specified and directed. | 2.50 | Qtl |