- Home
- >
- Tender
- >
- Punjab Tender
- >
- Department of Indian Institute of Technology Ropar
- >
NTID 44256119
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowProviding Vrv vrf Enabled Cond in Rupnagar - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Providing Vrv vrf Enabled Cond" in Rupnagar, India.
- Opening Date : Tue 17th March, 2026
- Closing Date : Mon 16th March, 2026
- ₹ 6038470.00
- NTID 44256119
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
120770.00 -
Document Cost
590.00 -
Estimated Cost
6038470.00
Latest Corrigendum List
| # | Corrigendum Title | Corrigendum Type |
|---|---|---|
| 1 | Extenstion of Date | Date |
| 2 | Financial Corrigendum | Financial Bid |
| 3 | Technical Corrigendum and Addendum | Technical Bid |
BOQ Items Total Items : 34 | Total Qty : 112
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Outdoor Unit | ||
| 2 | Supply, Installation, Testing & Commissioning of factory fitted microprocessor based self-diagnostic auto check VRV/VRF system outdoor unit equipped with PCBs, accumulator, oil separator, brushless DC inverter fan motor, OEM self- manufactured hermetic sealed multi valve scroll type compressors. Compressor should be based on low pressure shell technology for longer life with integrated IPM & PWM to ensure effective operation even at low/partial load conditions for better efficiencies. Compressor shall be fixed in metallic chamber for lower noise with enhanced fire safety protection. Outdoor unit shall be equipped with highly efficient induction type heater using eliminated wasted heat. VRT/VET system shall be based on advanced & automatically modulation evaporating refrigerant temperature between 0 C to 11 C for instant cooling and better energy efficiency as per user's demand. Outdoor units shall be essentially equipped with safety devices like fuse, noise filter PCB, low pressure switch, high pressure switch, pulse based LEV for optimized refrigerant flow control, isolating valve, protective corrosion resistant polyester coating on panels, hydrophilic coating on Aluminium fins, protective polyurethane coating on PCB, OEM provided Inbuilt automatic reverse phase detector & sequencer/corrector to avoid any kind of failure due to phase sequence reversal which makes system reliable and redundant. Heat exchanger must be essentially equipped with internally grooved copper tubes for better heat exchange performance and operate in extreme conditions i.e. even at ambient temperature of 52 C or more. Outdoor units shall be pre-charged with R410A gas, pump down function and shall also be equipped with charging valve/ports for additional charge of refrigerant as per site requirement. All outdoor unit shall be able to perform in duty cycle mode to optimize wear and tear of system when more than one outdoor unit is connected to a circuit. Outdoor units must also be equipped with four-way valve for necessary provision of heating during winters. All outdoor shall have approximately following as per OEM standards rated capacities at ARI conditions and, with the criteria of delivering 95% capacity at 43 C being most likely temperature to occur during summers. (All Unit shall confirm the detailed specification of tender document and providing power/ control cabling/earthing of indoor unit complete with supplying of all material in all respect as per specifications and any other items required to make the system complete as required). MAKE: MITSUBISHI, FIJITSU GENERAL, DAIKIN | ||
| 3 | 42 HP Heating and cooling Top Discharge | 2.000 | Nos. |
| 4 | Indoor Unit | ||
| 5 | Supply, Installation, Testing and Commissioning of VRV/VRF Cassette type indoor units with factory fitted electronic expansion valve, multi speed fan motors, dynamically balanced blowers, synthetic washable plasma media filter with hydrophobic coating on cooling coil. Electronic components like PCBs must be essentially enclosed in a metal box compartment being integrated part of indoor unit to ensure enhanced fire protection with auto by pass technology allowing uninterrupted operation of indoor units connected to a circuit in event of break down in any indoor connected to same circuit. All indoor units shall have individual fan speed and temperature control mechanism to be operated from corded remote. In addition to all indoor units can also be operated from central remote control. (All Unit shall confirm the detailed specification of tender document and providing power/ control cabling/earthing of indoor unit complete with supplying of all material in all respect as per specifications and any other items required to make the system complete as required). MAKE: MITSUBISHI, FIJITSU GENERAL, DAIKIN |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054