- Home
- >
- Tender
- >
- Delhi Tender
- >
- Department of DELHI JAL BOARD
- >
NTID 44456628
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowProcurement Of Turbidity Meter in Delhi - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Procurement Of Turbidity Meter" in Delhi, India.
- Opening Date : Fri 20th March, 2026
- Closing Date : Fri 20th March, 2026
- ₹ 0.00
- NTID 44456628
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
21300.00 -
Document Cost
500.00 -
Estimated Cost
Refer Documents
BOQ Items Total Items : 1 | Total Qty : 4
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Portable Turbidity Meter Model: 2100Q Technical Specification of Portable Turbidity Meter Make: HACH/WTW/Merck/Thermo Fisher or any other DJB Approved make Technical Specification of of Portable Turbidity Meter must have ratio turbidimetric determination using a primary nephelometric light scatter signal 90 to the transmitted light scatter signal meets EPA & ISO 7027 certified as follows: Measurement Specifications: Measurement Principal: Ratio turbidimetric determination using a primary nephelometric light scatter signal 90 to the transmitted light scatter signal. Measurement Range: 0 to 1000 NTU (FNU) Accuracy: 2% of reading plus stray light from 0 to 1000 NTU Repeatability: 1% of reading, or 0.01 NTU (FNU), whichever is greater Resolution: 0.01 NTU (lowest range) Compliance: EPA Method 180.1 & ISO 7027 Stray Light: less than 0.02 NTU Signal Averaging: Selectable on/off Detector: Silicon photovoltaic Light Source: Tungsten filament lamp Reading Modes (user selectable options): Normal (Push to Read),Signal Averaging, Rapidly Settling Turbidity Rapidly Settling Turbidity (RST) Mode: for improved measurement of unstable & settling samples. Dual Detector Optical System: for light fluctuation, compensates of color & stray light interference, On-Screen assisted Calibration and Verification: to minimize operator error. All the core measurement information is on a single screen. Data Logging Capacity: 500 records or better with date, time & calibration status Mechanical & Operational Requirements Power Supply: 4 AA alkaline batteries & AC Power with USB port Operating Temperature: 0 to 50 C Storage Temperature : -40 to 60 C Instrument Enclosure Rating: IP67 Protection Class: Power Supply: Class II Certification: CE certified Sample Volume: 15 mL or better Sample Cells : 60 x 25 mm round glass with screw cap 3. Accessories to be supplied: carrying case with calibration standards in 1" sealed vials of 20, 100, 800 NTU), 6 sample glass round cells with screw-tops, instrument manual, silicone oil and oiling cloth Warranty : The instrument shall be supplied with a minimum one year comprehensive warranty from the date of installation. | 4.00 | Nos. |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054