- Home
- >
- Tender
- >
- Andhra Pradesh Tender
- >
- Department of Hindustan Shipyard Limited
- >
NTID 44426794
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowOverhauling Of Oil Water Separ in Visakhapatnam - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Overhauling Of Oil Water Separ" in Visakhapatnam, India.
Hindustan Shipyard Limited
Visakhapatnam, Andhra Pradesh, India
NTID 44426794
- Opening Date : Wed 18th March, 2026
- Closing Date : Wed 18th March, 2026
- ₹ 0.00
- NTID 44426794
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
25000.00 -
Document Cost
Refer Documents -
Estimated Cost
Refer Documents
BOQ Items Total Items : 8 | Total Qty : 7
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | The complete inspection,overhauling, pressure testing, and proving of OWS system and satisfactory trials to be shown to the ship, required spares,consumables,certified tools and tackles,measuring instruments shall be within the contractor's scope of supply. | ||
| 2 | OWS system - Inspection and Overhauling Isolate OWS and ensure safe working conditions, Drain oil, water & sludge from OWS unit, Dismantle ows chamber,filters and internal components , Clean all chambers, filters elements and coalescer plates, Inspect parts for corrosion,cracks or damage parts, Renew damaged gaskets,seals and filter elements, Reassemble ows Unit as per manufacturere instructions. | 1 | LS |
| 3 | OWS Mountings, pipelines & Valves Inspect ows mounting, foundation bolts and supports, Inspect inlet,outlet & disccharge pipe line, Overhauling associated valves and fittings, Renew defective components as required. | 1 | LS |
| 4 | Pressure testing Blank off all system and connecteing pipe lines, Carry out hydrostatic pressure test of ows unit, Presuure test associated v pipeline and valves check leakage and pressure drop, and record pressure results | 1 | LS |
| 5 | 15PPM Bilge Alarm/ Monitor calibration Inspect and clean 15 PPM bilge alarm and sensors, Calibrate using certified test fluids,Verify alarm activation at 15PPM, Check interlock with overboard discharge valve, Obtain calibration certification from class approved agency. | 1 | LS |