NTID 44029336
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowCorrigendum Hvac Reconfigura in Chittoor - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Corrigendum Hvac Reconfigura" in Chittoor, India.
Indian Institute of Science Education and Research
Chittoor, Andhra Pradesh, India
NTID 44029336
- Opening Date : Sat 28th February, 2026
- Closing Date : Fri 27th February, 2026
- ₹ 0.00
- NTID 44029336
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
2288465.00 -
Document Cost
590.00 -
Estimated Cost
Refer Documents
Latest Corrigendum List
| # | Corrigendum Title | Corrigendum Type |
|---|---|---|
| 1 | Extension for Closing date of Bid | Date |
| 2 | Pre Bid Meeting Minutes | Other |
| 3 | Corrigendum | Technical Bid |
BOQ Items Total Items : 142 | Total Qty : 24308.5
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Removing of refrigerant gas from the system, disconnection of copper pipes and electrical supply teriminations both from supply side, panels side and equipment side of the following VRV out door units, lifting the outdoors from terrace by using appropriate unloading means like hydra/crane or deric system, shifting to the new location as per design. | ||
| 2 | 12 HP | 12.00 | each |
| 3 | Existing supply and return air inside ducts in each lab bay in the UB Lab building to be dismantled and shifted to the designated location within campus, ensuring no damage for reuse in the new sports complex. Agency has to quote the rate that room is fully equiped with all lab equipments proper care has to be take to avoid any damage. | 6.00 | job |
| 4 | Removing of existing all sizes of copper refrigerant piping with proper care so as to reuse to the maximum possible extent. Pipe ends should be sealed to prevent dust entry and oxydisation. These pipes are to be flushed with dry nitrogen. Agency has to execute the work incordination with IISER team for joint measurement. | 300.00 | meter |
| 5 | Installation testing & comissioning of following unit which includes necessarry civil pedastals by using MS stands, as recommended by OEM with suitable vibration isolation pads to avoid vibration etc as required. |