- Home
- >
- Tender
- >
- Maharashtra Tender
- >
- Department of Automotive Research Association of India
- >
NTID 47136320
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowElectrical Installation And Al in Chakan - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Electrical Installation And Al" in Chakan, India.
Automotive Research Association of India
Chakan, Maharashtra, India
NTID 47136320
- Opening Date : Mon 9th November, 2026
- Closing Date : Fri 6th November, 2026
- ₹ 0.00
- NTID 47136320
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
1613060.00 -
Document Cost
Refer Documents -
Estimated Cost
Refer Documents
BOQ Items Total Items : 66 | Total Qty : 0
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Supply, Installation, Testing, Commissioning, Transportation, handling, unpacking, erection of equipments as listed below. Minor civil work, alignment and leveling, at different elevations, spot welding, fixing of bolts, application of touch-up paint and other associated works complete with all labour, tools & tackles, consumables etc.It also includes required fabrication work with proper size Angles / Channels etc for mounting of Switchboards / Panels. Foundations, Trenches etc civil work will be done by civil contractor, Proper alignment, tightening of bus bars with required torque as instructed by Manufacturer / engineer in charge. Any modification / alteration to be carried out in individual shipping section for proper Assembling / alignment is to be done by the Contractor. It also includes Transportation of unpacked wooden crates / covers / Material from work site to scrap yard in the scope of Contractor. | ||
| 2 | VCB PANEL - Switch gear shall be Indoor type VACCUM Circuit Breaker Panel as per IEC 62271 with IP54 as per IS:3427 protection. It consists of S/C, O/L, E/F, Trip Setting on Relay and remotly, Alarms, Flash type Fault Indicators, duly internal complete control cabling and in standard size Cubicle. For Outgoing VCB Panel should be consisting of relay as above and in addition to this it should have Restricted Earth Fault protection relay for Transformers. Transformer Protections like WT, OT, OSR, PRV.MOG and BUCH etc. (Alarm & Trip) through aux. relay. It should also consists of Power monitoring device having communication port with protocol of other Energy meters. The complete Switchboard (VCB Panel ) will be free standing floor Mounting Type & This panel should be provision for expansion breaker panel at right hand side. (Trench work is in the scope of other agency). Control voltage should be considered as 24VDC. | ||
| 3 | 1 No. 1600A, 22 kV, 25KA, 3 Phase, 50Hz., metal clad, dead front, 25KA rupturing capacity, Fully Draw out type, Vacuum Circuit Breaker (VCB) 1 NO.0-22kV Energy Monitor Device ( Load Manager)with RS 485 Port 1 set of 22kV/√3 /110/√3 100VA CL:0.2S Potential Transformers with HRC fuses for metering and protection. 1 set of 1600/400/200/1/1 A Current Transformer for metering and protection 1 Set of Phase indicating lamps with HRC fuses 1 No. digital ammeter with inbuilt selector switch 1 No. 0-22 kV digital voltmeter with inbuilt selector switch 1No. Protection relay having metering & Modbus or Ethernet Communication Port, (Equiv. to Schneider S20 Series) 1 set of indicating lamps to indicate OPEN, CLOSE, TRIP, SPRING CHARGED, TRIP CIRCUIT HEALTHY, TEST, CONTROL SUPPLY ON, SERVICE Push button for CLOSE and TRIP & TRIP CIRCUIT HEALTHY, Emergency , 8 window Alarm annunciator with separate hooter, accept and rest push buttons | Nos | |
| 4 | BATTERY AND BATTERY CHARGERS Supply, installation, testing and commissioning of Battery charger with battery bank & DC Distribution board. Input Voltage 230V AC, 50 Hz, Output voltage 24V/DC. Charging current 20A DC. Battery charger shall have float charger & boost thyristor/IGBT controlled charger (course & fine adjustment).Battery bank shall consist of 100AH SMF (VRLA) valve-regulated lead–acid batteries of 12 cells of 2V. DC Distribution Board shall comprise of comprising 1 Incomer (32A)and 6 outgoing double pole MCBs.(10A). All necessary interlocking arrangements to be provided as per standards and as indicated in the drawings. This should also cover the necessary BMS requirements. Battery Chargers consist of following: 1 No. AC Voltmeter (0-500Volt) 1 No. DC Voltmeter 1 No. DC Ammeter 1 set of AC and DC indicating lamps 1 No. DC Battery charging position indicator DC distribution board suitable for above application to incoming & outgoing MCBs include tripping, closing and indication etc. Control cabling between DC Distribution panel to the MV Panel of the Substation with suitable core 1.5 sqmm copper cable. | Nos | |
| 5 | Supply, Installation, Testing, Commisioning, Site Storage and Foundation work for Metering Kiosk with 0.2S Class CT & PT ( with 3 nos of CT's, 3 nos of PT's 22/√3 KV / 110/√3 V., ( Make of Metering kiosk with CT & PTs 's to be as per MSEDCL Load Sanction letter) (With T.O.D. meter) for Check Meter | Nos |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054