- Home
- >
- Tender
- >
- Uttar Pradesh Tender
- >
- Department of Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited
- >
NTID 42352040
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowCorrigendum Supply Of Portab in Parichha - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Corrigendum Supply Of Portab" in Parichha, India.
Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited
Parichha, Uttar Pradesh, India
NTID 42352040
- Opening Date : Tue 23rd December, 2025
- Closing Date : Sat 20th December, 2025
- ₹ 0.00
- NTID 42352040
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
5000.00 -
Document Cost
590.00 -
Estimated Cost
Refer Documents
Latest Corrigendum List
| # | Corrigendum Title | Corrigendum Type |
|---|---|---|
| 1 | Date-extension-09.11.2025 | Date |
| 2 | Date-extension-15.11.2025 | Date |
| 3 | Date-extension-22.11.2025 | Date |
| 4 | Date-extension-29.11.2025 | Date |
| 5 | Date-extension-06.12.2025 | Date |
| 6 | Date-extension-13.12.2025 | Date |
BOQ Items Total Items : 4 | Total Qty : 5
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Enclosed AUTO/Manual CHANGEOVER SWITCH WITH CONTROLLERS 4 POLE 415 V AC 3 PH, CAPACITY 630A make -HPL, SIEMENS,L&T,HAVELLS. Rating & Service630 A, 4-pole, 415 V 10%, 50 Hz, 3-phase 4-wire (TPN), TN-S earthing.Continuous transfer capacity 630 A; short-circuit withstand 50 kA (1 s) or site fault level. Contactor-based ATS (2 4P power contactors) fast transfer (100 300 ms). busbars & Termination ETP copper busbars sized for 630 A (neutral 100%, earth 50%), tinned palms, torque-marked lugs, top/bottom gland plate. Controls & Logic AMF controller with mains/alternate supply, phase loss/sequence, programmable delays (start, warm-up, transfer, re-transfer, cool-down), retries. Local Auto/Manual/Test selector, start/stop, indicators (Mains, alternate source), alarms. Safety & Interlocks Mechanical + electrical interlock (no paralleling), door interlock, emergency stop. Metering & Interface (optional) Multifunction meter (V, A, kW, kWh) Standards & Tests IEC 61439-1/2, IEC 60947 series, IS 3043 wiring; routine tests: IR 1 G (500 V), 2.5 kV AC dielectric, functional simulation. | 1 | EA |
| 2 | Submersible Pump 1.1KW/1.5HP, Discharge Range = 400 - 65 LPM, Power - 0.75/1.0KW/HP, HEAD = 5-11M,Speed = 2900rpm, Single Phase.MAKE-KIRLOSKAR,CROMPTON GREAVES,HAVELLS. | 2 | EA |
| 3 | Technical Requirement Item: 3 32-Way 800 A Enclosed Bolted Bus Bar Chamber with MCCB 800 A Bus Bar Chamber Type: Enclosed, bolted type, dust & vermin proof. Rating: 800 A, 3-phase, 4-wire system, 50 Hz. Ways: 3 rows 32 ways each. Material: High conductivity electrolytic copper / ETP grade aluminium bus bars, tinned plated. Insulation: Heat-shrink / PVC sleeve, rated for 1100 V. IP-55 protection. Supports: Non-hygroscopic, non-tracking, high strength insulating supports. Terminations: Suitable for cable lug connections. Circuit Breaker (Incoming) Type: MCCB, 800 A, 3-pole, 50 kA breaking capacity (minimum). Trip Unit: Thermal-magnetic or electronic with adjustable overload & short circuit protection. Conforms to IS/IEC 60947-2. General All equipment to comply with IS/IEC standards. Proper earthing arrangement as per IS 3043. Nameplate & identification marking for incoming & outgoing feeders. All connections to be accessible for maintenance. MAKE-HAVELLS,HPL,L&T,SCHNEIDER,C&S,ABB. | 1 | EA |
| 4 | Item: 3 8-Way 200 A Enclosed Bolted Bus Bar Chamber with MCCB 200 A Bus Bar Chamber Type: Enclosed, bolted type, dust proof. Rating: 200 A, 3-phase, 4-wire system, 50 Hz. Ways: 3 rows 8 ways each. Bus Bar Material: High-conductivity electrolytic copper or ETP-grade aluminium, tinned plated. Insulation: Heat-shrink / PVC sleeves rated for 1100 V. Enclosure: CRCA steel sheet, min. 14 SWG, powder coated, IP-55 protection class. Supports: Non-hygroscopic, non-tracking, high-strength insulating supports. Terminations: Suitable for cable lug connections. Circuit Breaker (Incoming) Type: MCCB, 200 A, 3-pole, min. 36 kA breaking capacity at 415 V AC. Trip Unit: Thermal-magnetic or electronic with adjustable overload & short-circuit protection. Conforms to IS/IEC 60947-2. General All equipment to comply with relevant IS/IEC standards. Earthing arrangement as per IS 3043. Nameplates & identification markings for incoming and outgoing feeder MAKE-HPL,SCHNEIDER,ABB,C&S,HAVELLS,L&T | 1 | EA |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054