- Home
- >
- Tender
- >
- Andhra Pradesh Tender
- >
- Department of Hindustan Shipyard Limited
- >
NTID 44673529
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowCorrigendum Serviceability C in Visakhapatnam - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Corrigendum Serviceability C" in Visakhapatnam, India.
Hindustan Shipyard Limited
Visakhapatnam, Andhra Pradesh, India
NTID 44673529
- Opening Date : Wed 8th April, 2026
- Closing Date : Wed 8th April, 2026
- ₹ 0.00
- NTID 44673529
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
26250.00 -
Document Cost
Refer Documents -
Estimated Cost
Refer Documents
Latest Corrigendum List
| # | Corrigendum Title | Corrigendum Type |
|---|---|---|
| 1 | DUE DATE EXTENSION | Date |
| 2 | SERVICEABILITY CHECKS OF BALLAST WATER TREATMENT SYSTEM ON INS PROJECT2 | Date |
BOQ Items Total Items : 5 | Total Qty : 43
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Serviceability checks of Ballast Water Treatment System on INS Project as per Technical specification is enclosed, Make - Alpha Laval ; Model - 901033-81. | ||
| 2 | BALLAST WATER TREATMENT PLANT: Carryout functional checks of all Pressure Transmitters (Range 0-10 Bar, Qty 20), Undertake calibration. Renew/ repair defective instrumentation. NOTE: All spares required for defect rectification should be supplied by Vendor. | 20 | NOS |
| 3 | BALLAST WATER TREATMENT PLANT: Carryout functional checks of all Pressure Gauges (0-10 Bar, Qty 20). Undertake calibration. Renew/ repair defective instrumentation. NOTE: All spares required for defect rectification should be supplied by Vendor. | 20 | NOS |
| 4 | BALLAST WATER TREATMENT PLANT: Carryout functional checks of all Flowmeters (Range 0-300m3/hr , Qty 02). Undertake calibration. Renew/ repair defective instrumentation. . NOTE: All spares required for defect rectification should be supplied by Vendor. | 2 | NOS |
| 5 | BALLAST WATER TREATMENT PLANT: Frequent hanging of HMI Panel and malfunctioning of penumatic valves of BWT plant observed during exploitation. Suspect PLC of plant malfunctioning. Undertake defect rectification. Make - Alpha Laval ; Model - 901033-81. NOTE: All spares required for defect rectification should be supplied by Vendor. | 1 | NOS |