- Home
- >
- Tender
- >
- Uttarakhand Tender
- >
- Department of Military Engineer Services
- >
NTID 42833418
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowCorrigendum Repair Maint Of in Roorkee - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Corrigendum Repair Maint Of" in Roorkee, India.
Military Engineer Services
Roorkee, Uttarakhand, India
NTID 42833418
- Opening Date : Fri 12th December, 2025
- Closing Date : Wed 10th December, 2025
- ₹ 1430000.00
- NTID 42833418
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
28600.00 -
Document Cost
500.00 -
Estimated Cost
1430000.00
Latest Corrigendum List
| # | Corrigendum Title | Corrigendum Type |
|---|---|---|
| 1 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum |
| 2 | Amendment to Tender Page NIT | Other |
BOQ Items Total Items : 61 | Total Qty : 8710
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Material and labour for disconnecting of distribution transformer indoor/outdoor type for testing/servicing /cleaning / repair etc, ensuring safety isolation and testing (IR values for HV/LV windings & winding-to-earth) oil level & condition checking (visual and BDV test), checking of bushings, including external inspection and re-connecting after carrying out required repair/testing servicing in the transformers. Recording of all test parameters and preparation of service report for the following capaity of Transformer :- NOTE :-(i) The cost of dismantling and assembly is deemed to be including. (ii) work to be carried out by qualified personael to ensure safe and reliable operation. Preventing maint/servicing of transformer will be carried out by any equipment manufacture/certified firm and work to be carried out as per standrded and recommendations complete in all respect. All test perameter service and report shall be submitted by contractor. (iii) If the transformer winding as per testing is burnt the reason for same should be mentioned in report and countersinged by GE. | ||
| 2 | Upto 250 KVA transformer | 12.00 | Each Job |
| 3 | above 250 to 500 KVA transformer | 14.00 | Each Job |
| 4 | above 500 to 750 KVA transformer | 2.00 | Each Job |
| 5 | Material and labour for preventive maintenence/servicing of distribution transformer indoor/outdoor type after disconnection and testing as mentioned item No 1 above , servicing and cleaning of transformer ,checking and tightening of all electrical/mechanical connections, checking of gasket, repairing of leakage e.i replacement of gland, change of brass nut/bolt, removing of corban from connection and joint, minor repair etc complete as directed by Engr- in- Charge for the following capaity of Transformer :- NOTE :-(i) The cost of dismantling and assembly is deemed to be including. (ii) work to be carried out by qualified personael to ensure safe and reliable operation. Preventing maint/servicing of transformer will be carried out by any equipment manufacture/certified firm and work to be carried out as per standrded and recommendations complete in all respect. All test perameter service and report shall be submitted by contractor. |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054