- Home
- >
- Tender
- >
- Jammu and Kashmir Tender
- >
- Department of Military Engineer Services
- >
NTID 43354899
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowCorrigendum Provn Of Transfo in Poonch - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Corrigendum Provn Of Transfo" in Poonch, India.
Military Engineer Services
Poonch, Jammu and Kashmir, India
NTID 43354899
- Opening Date : Tue 17th February, 2026
- Closing Date : Tue 10th February, 2026
- ₹ 3569000.00
- NTID 43354899
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
71380.00 -
Document Cost
500.00 -
Estimated Cost
3569000.00
Latest Corrigendum List
| # | Corrigendum Title | Corrigendum Type |
|---|---|---|
| 1 | Corrigendum 1 | Date |
| 2 | Corrigendum 2 | BOQ |
| 3 | Corrigendum 3 | Date |
| 4 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum |
| 5 | Corrigendum 2 | BOQ |
| 6 | Corrigendum 3 | Date |
| 7 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum |
| 8 | Corrigendum 2 | BOQ |
| 9 | Corrigendum 3 | Date |
BOQ Items Total Items : 27 | Total Qty : 310.69
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Supply, installation, testing and commissioning of Servo controlled voltage stabilizer (confirming to BIS 9815 (Part-1) 1994, reaffirmation 2019 latest version) Three phase, four wire (RYBN), 50 Hz, Naturally Oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting Hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of Transformer oil up to level having following specification:- (a) Capacity 150 KVA (b) Type - Suitable for unbalanced load and unbalanced input (c) Input voltage -360V-480V, Input frequency 50 Hz (d) Output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) Rated frequency - 50 Hz (f) Wave form distortion - Nil (g) Response time - not to exceed 20 milli seconds (h) Sensitivity - (+/-) 1% (j) Rate of correction - Not less than 6 Volt/second between phase and neutral (k) Efficiency - more than 95% (l) Type of load - three phase, unbalanced type (m) Metering - Digital display Voltmeter/Ammeter with multi-functional meter (n) Operating temperature - For indoor use upto max ambient temp + 55 C (o) Dimmer rating - 200 Amp (p) Dimension of tanks - as per OEM design (q) Oil capacity- as per OEM design | 1.00 | Each |
| 2 | (r) Class of insulation - Class F (s) Mode of operation Automatic/manual (t) Winding Temperature rise - Max 55 C (10 C above operating temp) (u) Transformer oil -IS 335 marked (v) Core-CRGO M4 Grade/CRNO (Cold Roll Grain Oriented)/ (Cold Rolled Non-Oriented) (w) Auto transformer (Variac) -100 percent Copper wound Electrolytic Grade (x) Losses - As per IS Norms (y) Power Factor - Not less than 0.95 (z ) Protection - (i) Over load protections (ii) Short Circuit protections (iii) High/Low voltage cut off (iv) By pass arrangement in case of Emergency (v) Single phase sequence change /phase fail protection (vi) Earth fault protection (aa) Standard Fitting & Accessories e.g Marking plate, lifting lugs, CI Rollers, Earthing Terminals, cable box including suitable platform as reqd on site complete all as as specified & directed. | ||
| 3 | Supply, installation, commissioning and testing of Silent Diesel Engine Generating Set comprising of diesel engine liquid- cooled (latest IS and CPCB- Norms ) & alternator, of output capacity not less than 160 KVA at site (DG Set to be installed at HAA 950m above MSL and capacity of DG set shall be selected, so as to deliver 160 KVA in all adverse conditions) 3 phase, 4 wire, 415 V, 50 Hz., 0.8pf at 1500 RPM, with control panel having all necessary switch gears for automatic starting on main failure (AMF Panel), both coupled and aligned on a common base frame complete with standard accessories like MS Fuel tank (having the minimum fuel capacity for running of DG set continously for 12 hours), AVM Pads fitted on base frame, Control Panel with digital measurement devices, alongwith accoustic enclosure with the confirmination of latest BS/IS and complete in all respects Including lubricating oil filled in engine, DG Set Manual comprising of following complete as as specified:- Prime Mover : Prime mover suitable for driving alternator 160 KVA Capacity having the suitable BHP at 1500 RPM for rated output for alternator in accordance with latest BS/IS Specification with electric starting device with all standard fittings and suitable capacity of lead acid maintenance free battery of 12 Volts as per manufracturer -01 nos with Battery and Charger Engine over speed safety mechanism shall be incorporated. The engine shall be equipped with standard fittings as per manufacture's recommendations. | 2.00 | Each |
| 4 | Engine Control Panel : (a) All relevant parameters shall be conventionally displayed on complete panel thereby providing easy monitoring of lub oil, pressure, Coolant Temperature, Battery charging, Ammeter, RPM, Hour meter and starting switch etc. (b) AMF Panel with Bye Pass arrangement for Main and DG Both supply, internal wiring and power contactors suitable for 160 KVA generator set, all as per manufacturer's recommendation. Bye Pass arrangement Main & DG set Supply along with all the parameters and accessories as per manufacturer recommendation and CPRI Approved & as per relevant IS. Fuel Tank : Fuel Tank of 12 hours capacity will be installed as per the manufacturer's requirement including all necessary pipe connections from fuel tank to engine and over flow from engine to tank. | ||
| 5 | Engine Alternator Engine Alternator of capacity 160 KVA output 3 Phase 50 HZ 415 Volts 4 wire AC supply 0.8 Power Factor at 1500 RPM self regulated self excised screen protected and drip type, insulation class 'H' continously rated brush less type conforming to relevant BS/ IS code as per current manufacturing shedule of standard manufacturer. Engine Alternator shall be mounted on specially designed base plate of rigid welded constructions with anti vibraton pads. The DG Set shall be placed on foundation including necessary civil works as per the manufacturer's recommendations/site requirement. The output of alternator not less than 160 KVA in all adverse conditiones, as the DG set to be installed at HAA 950 m above MSL. Note:- (a) The unit rate shall deemed to include the cost of Diesel and lubrication required for testing and commissioning of DG Set as per department procedure and shall be arranged by contractor. (b) Extenssion of exhaust pipe for DG set along with standerd accessories like flange, nut bolts , asbestous rope etc. shall be provided by the contractor and the cost of the same shall be included in the unit rate quoted by contractor. (c) Cost of foundation and necessary civil works as per the manufacturer's recommendations/site requirement shall be incuded in the unit rate quoted by the contractor. |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054