- Home
- >
- Tender
- >
- Madhya Pradesh Tender
- >
- Department of Military Engineer Services
- >
NTID 40161075
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowCorrigendum 752942a Allied W in Jabalpur – Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Corrigendum 752942a Allied W" in Jabalpur, India.
Military Engineer Services
Jabalpur, Madhya Pradesh, India
NTID 40161075
- Opening Date : Tue 8th July, 2025
- Closing Date : Tue 1st July, 2025
- ₹ 45296000.00
- NTID 40161075
Tender Description
Documents
Get Complete Tender Details Now – Download the Document!
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
528000.00 -
Document Cost
2000.00 -
Estimated Cost
45296000.00
Latest Corrigendum List
# | Corrigendum Title | Corrigendum Type |
---|---|---|
1 | Corrigendum No 01 | Date |
2 | Corrigendum No 02 | Date |
3 | Corrigendum No 03 | Date |
BOQ Items Total Items : 287 | Total Qty : 17356.4
# | Item | Quantity | Units |
---|---|---|---|
1 | Schedule 'A' Acoustic wall panneling | ||
2 | Item No. 01 : PET PANEL PANELING @ 8 FEET FROM FFL : Supply Installation Testing and Commissioning of Pet panels with acoustical properties made of 100 % polyster fibre with thickness of 9 mm homogenieous material with so many color option as per the choice of the architect / person in charge of size 2440 mm x 1220 mm. Can be cut in to any size for E G like 600 mm x 600 mm 1200 mm x 600 mm etc. as per client requirement. NRC Value of the eccoboard will 0.6. should be weather ressitant with anti fungal properties. Thermal insulation should be easy to install with the help of water proof bostik / fevicol SR 505 Adhesive. on the walls of the auditorium using GI frame work of 48mm GI Studs using 0.55mm thick and stud channels at 610mm x 610mm, 0.5mm thick, fixed with MS angle cleats 1220x610mm centers to wall by using metal fasteners, backed with 24 SWG x 12.5mm GI Chicken Wire Mesh with air gap a minimum of 50mm on back side, as per detailed drawing. The frame work to be filled with 50 mm thick micron having the density of 1000 GSM to achieve the 1.0 NRC value Then 8 mm perforated Boiling Water Proof, FR is Born Tough HDF Board density is above 1000 kg/m3 Borer Proof and Termite proof board will be nailed on G.I. frame. Finally 9mm thick pet panels will be paste on 8 mm perforated board with the help of S.R. | 304.00 | SQM |
3 | Item No. 02 : STRECHED FABRIC IN UPVC GRIPPER PANELING FROM 8 FEET TILL CEILING LVL Supply Installation Testing and Commissioning of Acoustical Panels on the side and back wall of the auditorium using GI frame of 48mm GI Studs using 0.55mm thick and stud channels at 610mm x 610mm, 0.5mm thick, fixed with GI angle 1220x610mm centers to wall by using metal fasteners, backed with 24 SWG x 12.5mm GI Chicken Wire Mesh with air gap a minimum of 50mm on back side, as per detailed drawing, 50 mm thick synthetic wool having the density of 1000 GSM to achieve the 1.0 NRC value, and chicken wire mesh support on the rear side abuting the wall face. Finally streched fabric will tucked into the gripper strips teeth and a tool stretch it tightly before fastening. this creates a smooth wrinkle free surface finish, using UPVC grippers fixed to 8 mm perforated Boiling Water Proof, FR is Born Tough HDF Board density is above 1000 kg/m3 Borer Proof and Termite proof board . | 256.00 | SQM |
4 | Item No. 03 : PET PANEL PANELING IN BETWEEN FABRIC PANELING Supply Installation Testing and Commissioning Pet panels with acoustical properties made of 100 % polyster fibre with thickness of 9 mm homogenieous material with so many color option as per the choice of the architect / person in charge of size 2440 mm x 1220 mm. Can be cut in to any size for E G like 600 mm x 600 mm 1200 mm x 600 mm etc. as per client requirement.NRC Value of the eccoboard will 0.6. should be weather ressitant with anti fungal properties. Thermal insulation should be easy to install with the help of water proof bostik / fevicol SR 505 Adhesive on the side walls of the auditorium using GI frame work of 48mm GI Studs using 0.55mm thick and stud channels at 610mm x 610mm, 0.5mm thick, fixed with MS angle cleats 1220x610mm centers to wall by using metal fasteners, backed with 24 SWG x 12.5mm GI Chicken Wire Mesh with air gap a minimum of 50mm on back side, as per detailed drawing. The frame work to befilled with 50 mm thick micron insulation synthetic wool having the density of 1000 GSM to achieve the 1.0 NRC value Then 8 mm perforated board will be nailed on g.i frame.Finally 9mm thick pet panels will be pasted on 8 mm perforated Boiling Water Proof, FR is Born Tough HDF Board density is above 1000 kg/m3 Borer Proof and Termite proof board with the help of S.R | 50.00 | SQM |
5 | Item No. 04 : STAGE WALL PANELING Supply Installation Testing and Commissioning Pet panels on the stage walls using GI frame work of 48mm GI Studs using 0.55mm thick and stud channels at 610mm x 610mm, 0.5mm thick, fixed with MS angle cleats 1220x610mm centers to wall by using metal fasteners, backed with 24 SWG x 12.5mm GI Chicken Wire Mesh with air gap a minimum of 50mm on back side, as per detailed drawing. The frame work to befilled with 50 mm thick micron having the density of 1000 GSM to achieve the 1.0 NRC value Then 8 mm perforated biolo board will be nailed on g.i frame. Finally 9mm thick pet panels will be paste on 8 mm perforated Boiling Water Proof, FR is Born Tough HDF Board density is above 1000 kg/m3 Borer Proof and Termite proof board with the help of S.R | 225.00 | SQM |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054