Conversion Of Electrical Energy Meters Into Smart Energy Meters (ph-i) In Old Amritsar Cantt Under Ge Amritsar
Documents
Unlock the opportunities
Buy This Document @200/--
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
190000.00 -
Document Cost
1000.00 -
Estimated Cost
11500000.00
BOQ Items Total Items : 17 | Total Qty : 4654
# | Item | Quantity | Units |
---|---|---|---|
1 | Taking down old Single / Three phase Energy Meter from any location and deposit to MES store complete all as specified and directed by Engineer-in-Charge/GE. The Quoted rate shall deemed to be inclusive of following parameters: - (a) Meter reading record shall be submitted before and after replacement duly signed by the contractor representative and MES representative. (b) Old meters should be handed over at AGE E/M store yard. (c) Any re-joining of wires / cables shall be done using suitable ferrule / cable connectors after removal of meter. (d) The cost of making disturbed surfaces good & matching to the existing surface is deemed to be included in the unit quoted rates and nothing shall be admissible on this account. | 789 | Each |
2 | Supply, Installation, Testing and Commissioning of 1-Phase 2-wire 240V Class 1.0 Smart Energy Meter complying to IS 16444 Part 1 at the rating of (5-30A)/(10-60A) suitable for Prepaid/Postpaid mode.The Smart Meter shall support the following minimum basic features : Measurement of electrical energy parameters; Bidirectional Communication; Integrated Load limiting /connect/disconnect switch; Tamper event detection; recording and reporting; Power event alarms; Remote firmware upgrade; TOD features; On demand reading. Meter shall have the ability to communicate with Head End System (HES) on RF Mesh Communication technology mentioned in IS16444 Part 1 in a secure manner. Data exchange protocol from smart meter to HES shall be based on open protocol like TCP/lP or DLMS/COSEM. RF Mesh network should use 865-867 MHz frequency band as permitted by WPC. Other RF Technologies like LoRAWAN, Zigbee, Bluetooth not desired. Equipment Type Approval (ETA) certificate mentioning Frequency range(s) of Equipment at 865-867 MHz to be produced. Replacement warranty of Energy meter 5 Years complete all as specified and directed by Engineer-in-Charge. | 745 | Each |
3 | Supply, Installation, Testing and Commissioning of 3-Phase, 4-wire, 3X240V, Class 1.0 Smart Energy Meter, BIS marked IS16444, at the rating of 10-60A suitable for Prepaid/Postpaid mode.The Smart Meter shall support the following minimum basic features:Measurement of electrical energy parameters; Bidirectional Communication; Integrated Load limiting /connect/disconnect switch; Tamper event detection; recording and reporting; Power event alarms; Remote firmware upgrade; TOD features; On demand reading. Meter shall have the ability to communicate with Head End System (HES) on RF Mesh Communication technology mentioned in IS16444 Part 1 in a secure manner. Data exchange protocol from smart meter to HES shall be based on open protocol like TCP/lP or DLMS/COSEM. RF Mesh network should use 865-867 MHz frequency band as permitted by WPC. Other RF Technologies like LoRAWAN, Zigbee, Bluetooth not desired. Equipment Type Approval (ETA) certificate mentioning Frequency range(s) of Equipment at 865-867 MHz to be produced.Replacement warranty of Energy meter 5 Years complete all as specified and directed by Engineer-in-Charge. | 44 | Each |
4 | Supply, Installation, Testing and Commissioning of DCUs/Gateways and the arrangement of Sim cards or Internet to enable reliable medium for two-way communication between Smart Meter & HES. The DCU/Gateway shall be compatible with the Smart Meters mentioned above. RF network should use 865-867 MHz frequency band. The data acquisition (Push/Pull) frequency shall be configurable 15 min, 30 min or 60 Minutes. It shall push events such as tamper, power off etc. to HES immediately on occurrence/receipt from meters. It shall have provision for the cellular, WiFi and Ethernet communication for the backhaul to HES. It shall be capable to handle data of minimum 1000 Nos. of any type of smart meter (1ph/3ph). It shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. Communication of the nearest meters with other meters shall be established through appropriate mesh formation. RF Mesh shall support self-forming and self-healing features. The equipment shall be weather proof and dust proof (minimum rating: IP54 for indoor and IP65 for outdoor installation). It shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc. Sim card or Internet Charges for 5 Years to be included. Replacement warranty of DCU/Gateway 5 years complete all as specified and directed by Engineer-in-Charge. | 5 | Each |
5 | Supply and Installation of RF Single Phase Smart Meter as repeater, complete all as specified and directed by Engineer-in-Charge. | 5 | Each |

Purchase Access To Download Selected Documents