- Home
- >
- Tender
- >
- Uttar Pradesh Tender
- >
- Department of Yamuna Expressway Industrial Development Authority
- >
NTID 46475614
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowContruction Of 11 0 415kv Subs in Gautam Budnagar - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Contruction Of 11 0 415kv Subs" in Gautam Budnagar, India.
Yamuna Expressway Industrial Development Authority
Gautam Budnagar, Uttar Pradesh, India
NTID 46475614
- Opening Date : Tue 8th September, 2026
- Closing Date : Mon 7th September, 2026
- ₹ 83197859.00
- NTID 46475614
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
1664000.00 -
Document Cost
6670.00 -
Estimated Cost
83197859.00
BOQ Items Total Items : 126 | Total Qty : 19569
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Bill of Quantity-A (For 5 Nos Electrical Substation) | ||
| 2 | Supply, Installations, Testing & Commissioning of 11kV HT PANELS Indoor type 4 panel board, 2 I/C and 2 O/G (1 T/F + 1 spare) 630 Amps, 11 KV, 3 phase, 25 KA for 1 sec. Vacuum circuit breaker including two bus PT with all necessary protection, metering and other accessories complete in all respect.as per the directions of the Engineer-in-charge Complete in all respects as per direction of the Engineer-in-charge. YEIDA SOR-67 | 5 | Nos. |
| 3 | Supply, delivery, assembly, installation, testing and commissioning of Outdoor type distribution transformer. 11/0.433 KV, 3 Phase, Double wound winding. Voltage ratio 11000/433-250 Volts, vector group Dyn 11. Air cooled with manually operated +5% and -10% off load Tap changer and complete with standard fitting & accessories as given in the specification and also confirming to IS: 1180 (Level-2) with first filling of the oil complete as required. (This includes oil testing for dielectric strength, flask over test and filtration of transformer oil to be conducted in the event of unsatisfactory results of oil testing. (Crompton, NGEF, Alstom, BHEL, Voltamp, Diamond, Reychem, Kanohar make) complete in all respect.as per the directions of the Engineer-in-charge. YEIDA SOR-74 (a) 630 KVA. Copper wound. | 5 | Nos. |
| 4 | Supply & Fixing of Main LT & APFC Consisting One Incoming 1000A,4P ACB EDO Type and 6 Nos Outgoing (5 No 400A TPN MCCB and 1 Nos 63A TPN MCCB ) with digital metering & Indicating lamps and Capacitor bank 250KVAR for APFC Panel Board & along with other accessories as required. complete in all respect.as per the directions of the Engineer-in-charge. YEIDA SOR-68 | 20 | Nos. |
| 5 | Supply, Assembling, Installation, Commissioning of Sealed maintenance free (SMF) 110V D.C., 150 AH batteries. The batteries shall rest on treated wooden planks fabricated from MS angle and free standing floor mounted rack with acid resistant finish and complete with series connecting electrical leads and charging of batteries. The batteries shall be accompanied with tester. This shall have incoming leads as well as outgoing leads and of suitable battery charger for 8 hrs. charge of 150AH battery charger enclosed in sheet metal with fan on top and it should automatically charge the batteries With booster and trickle charge. |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054