Inquiry NowConstruction Of Heliport At Ja in Una-HP - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Construction Of Heliport At Ja" in Una-HP, India.
Public Works Department
Una-HP, Himachal Pradesh, India
NTID 45217889
- Opening Date : Mon 25th May, 2026
- Closing Date : Mon 25th May, 2026
- ₹ 5760609.00
- NTID 45217889
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
115200.00 -
Document Cost
2000.00 -
Estimated Cost
5760609.00
BOQ Items Total Items : 61 | Total Qty : 2398
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Supply, Installation, Testing & Commissioning of factory fitted mircoprocessor based self diagnostic auto check VRV/VRF system outdoor unit equiped with PCBs, accumulator, oil seperator, burshless DC inverter fan motor, OEM self manufactured hermetic sealed multi valve scroll type compressors. Compressor should be based on low pressure shell technology for longer life with integrated IPM & PWM to ensure effective operation even at low/partial load conditions for better efficiencies. Compressor shall be fixed in metallic chamber for lower noise with enhanced fire saftey protection. Outdoor unit shall be equiped with highly efficient induction type heater using eliminated wasted heat. VRT/VET system shall be based on advanced & automatically modulation evaporating refrigerant temperature between 0 C to 11 C for instant cooling and better energy effiency as per user's demand. Outdoor units shall be essentially equiped with saftey devices like fuse, noise filter PCB, low pressure switch, high pressure switch, pulse based LEV for optimized refrigerant flow control, isolating valve, protective corrosion resistant polyster coating on panels, hydrophilic coating on Aluminium fins, protective polyeurethane coating on PCB, OEM provided Inbuilt automatic reverse phase detector & sequencer/corrector to avoid any kind of failure due to phase sequence reversal which makes system relaible and redundant. Heat exchanger must be essentially equiped with internally grovved copper tubes for better heat exchange performance and operate in extreme conditions i.e. even at ambient temparature of 52 C or more. Outdoor units shall be pre-charged with R401A gas, pump down fucntion and shall also be equipped with charging valve/ports for additional charge of refrigerant as per site requirement. All outdoor unit shall be able to perform in duty cycle mode to optimize wear and tear of system when more than one outdoor unit is connected to a circuit. Outdoor units must also be equiped with four way valve for necessary provision of heating during winters. All outdoor shall have approximately following as per OEM standards rated capacities at ARI conditions and, with the criteria of delivering 95% capacity at 43 C being most likey temperature to occur during summers.to complete the job including five year on site warranty. The rates are inclusive of carriage of materials within all leads and lifts and all taxes of octroi ,royality, malkana, toll tax,sale tax Gst or other taxes as imposed by the Govt time to time where applicalble The system shall be compatible with BMS and contractor shall submit shop drawings before starting the work. Make : O General, Mitsubishi, Daikin. | ||
| 2 | Outdoor Unit per HP | 66.00 | Nos. |
| 3 | Supplying, Installation, Testing and Commissioning of following minimum capacity and external static pressure VRF/VRV ceilingmounted mid high static ductable type Indoor unit equipped with washable synthetic media pre filter, fan sectionwith low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration Isolators, drain pan, drain pump, other necessary supports etc., suitable for operation on single phase AC supply 230 V 10%, 50 Hz complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor) High Static Ductable units (minimum 49 to 77 pascal external static pressure) to complete the job including five year on site warranty. The rates are inclusive of carriage of materials within all leads and lifts and all taxes of octroi ,royality, malkana, toll tax, sale tax Gst or other taxes as imposed by the Govt time to time where applicalble . Make :- Daikin/O General/ Mitsubishi | ||
| 4 | Ductable Type Indoor Unit 5.5 TR High Static Ductable units (minimum 78 pascal external static pressure) | 2.00 | Nos. |
| 5 | Ductable Type Indoor Unit - 4.0 TR | 2.00 | Nos. |