- Home
- >
- Tender
- >
- Kerala Tender
- >
- Department of Drugs Control Department
- >
NTID 45431077
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowComprehensive Annual Maintenan in Thiruvananthapuram - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Comprehensive Annual Maintenan" in Thiruvananthapuram, India.
Drugs Control Department
Thiruvananthapuram, Kerala, India
NTID 45431077
- Opening Date : Tue 7th July, 2026
- Closing Date : Fri 3rd July, 2026
- ₹ 400000.00
- NTID 45431077
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
BOQ Items Total Items : 1 | Total Qty : 1
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | I) Clean Room Validation as per grade A, B, C & D (i) Air Flow Velocity (ii) Air Changes per Hour(iii) Filter Integrity Test (iv) Differential Pressure (v) Recovery Time (vi) Room Temperature & Humidity(vii) Particle Count II) Maintenance, Servicing & Overhauling works of HVAC System A) Air Handling Units - 3 Nos (8.5 Ton x 2 Nos. & 5.5 Ton x 1 No.) (i) Flushing and Cleaning of Finned Surface & DX Tubes of Cooling Coils(ii) Checking & Replacement of faulty Fan Bearing(iii) Checking & Replacement of faulty Motor Bearing(iv) Checking of Belt Allignment and Tension & Mounting Bolts.(v) Cleaning of Filters, Replacement of Defective Belts, Pulleys, Blowers, Shafts, Bearings of AHUs whenever found defective. B) Electrical Panels and Wiring (i) Checking and Servicing of Contactors, Capacitors, Overloads, MCCBs and Fuses, Tightening of wiring connections and Replacement of faulty parts if required.(ii) Checking of Wiring Insulations & Motor Winding (iii) Checking of Earthing. C) Outdoor Units - 3 Nos (8.5 Ton x 2 Nos. & 5.5 Ton x 1 No.) Flushing & Cleaning of finned surface of condenser, General Change of compressor oil if required, greasing of bearing and oiling wherever required, replacement of motors and compressor if required. Topping of refrigerant whenever required. Rectification of leak if any and testing the system with nitrogen pressure and re-commissioning after vaccumization, replacement of insulation sleeves on Copper tubings. Validation Frequency: 2 tests per year, Breakdown attendance: Within 24hrs | 1 | No |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054