- Home
- >
- Tender
- >
- Haryana Tender
- >
- Department of Military Engineer Services
- >
NTID 44487919
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowCorrigendum Ca No Cwe ggn ft in Faridabad - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Corrigendum Ca No Cwe ggn ft" in Faridabad, India.
- Opening Date : Wed 8th April, 2026
- Closing Date : Mon 6th April, 2026
- ₹ 2000000.00
- NTID 44487919
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
40000.00 -
Document Cost
500.00 -
Estimated Cost
2000000.00
Latest Corrigendum List
| # | Corrigendum Title | Corrigendum Type |
|---|---|---|
| 1 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum |
BOQ Items Total Items : 70 | Total Qty : 3088
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | M&L for cleaning of STP of capacity 200 KLD equalizing tank /grit chamber/ oil grease chamber/ silting chamber of Sewage Water in the tank and removing of settle down Sewage sludge cum mud/ De-Silting etc and making good the patches on walls internally or externally in cement mortor (1:3) where required complete all as required at site and directed by the Engineer-in-Charge. Note: The cleaning should be done in every three months through machinary equipments. | 2.00 | Each Job |
| 2 | M&L for cleaning of STP of capacity 200 KLD sludge holding tank of Sewage treatment plant and removing of settle down Sewage sludge cum mud/ De-Silting etc and making good the patches on walls internally or externally in cement mortor (1:3) where required complete all as required at site and directed by the Engineer-in-Charge. Note for item No 1 & 2:- The rate quoted by the tenderer is deemed to be included in the unit rate of the following:- (a) Pump Set of appropriate capacity with operators including necessary connections required at site including PVC heavy duty flexible hose pipe for suction and delivery purposes. (b) Lorry/Tractor mounted septic storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same to the location where approved by the FMDA/MCF (c ) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineer-in-Charge. Note: The cleaning should be done in every three months through machinary equipments. | 2.00 | Each Job |
| 3 | M&L for cleaning of STP of capacity 200 KLD of Fab-1 and Fab-2 of Sewage treatment plant and removing of settle down Sewage sludge cum mud/De-Silting etc and making good the patches on walls internally or externally in cement mortor (1:3) where required complete all as required at site and directed by the Engineer-in-Charge. Note: The cleaning should be done in every three months through machinary equipments. | 3.00 | Each Job |
| 4 | M&L for cleaning of STP of capacity 200 KLD Tube settler of Sewage treatment plant and removing of settle down Sewage sludge cum mud/De-Silting etc and making good the patches on walls internally or externally in cement mortor (1:3) where required complete all as required at site and directed by the Engineer-in-Charge. Note: The cleaning should be done in every three months through machinary equipments. | 3.00 | Each Job |
| 5 | M&L for cleaning of STP of capacity 200 KLD treated water tank with chemical contact tank of STP by removing of all deposited sludge, scale or other unwanted materials from the tank by any means and removing the same to out site MOD land and after cleaning, washing and scraping the wall complete all as specified and directed by Engr-in-Charge. Note for item No 3 to 5 : The rate quoted by the tenderer is deemed to be included in the unit rate of the following:- (a) Pump Set of appropriate capacity with operators including necessary connections required at site including PVC heavy duty flexible hose pipe for suction and delivery purposes. (b) Lorry/Tractor mounted septic storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same to the location where approved by the FMDA/MCF (c ) Necessary Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineer-in-Charge. (d) Injection grouting with waterproofing chemicals in leakages surfaces as directed by Engineer-in-Charge. (e ) Exposed external surfaces shall be finished with two coats of cement base paints. (f) Internal surfaces shall be finished with two coats of epoxy paint. Note: The cleaning should be done in every three months through machinary equipments. | 2.00 | Each Job |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054