Inquiry NowAugmentation Of Old Hvac Plant in Kamrup - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Augmentation Of Old Hvac Plant" in Kamrup, India.
- Opening Date : Wed 10th December, 2025
- Closing Date : Tue 9th December, 2025
- ₹ 62280502.00
- NTID 42832738
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
1246000.00 -
Document Cost
5000.00 -
Estimated Cost
62280502.00
BOQ Items Total Items : 129 | Total Qty : 3833
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | PART-A: Equipment | ||
| 2 | WATER-COOLED CENTRIFUGAL CHILLING UNIT (600 TR) | ||
| 3 | Supplying, Installing, testing & commissioning of water cooled Positive/Negative pressure Centrifugal Type water chilling machine with unit mounted 2 stage factory fitted Variable Frequency Drive control console, with inbuilt Active Harmonic filter having THDi <= 5% (at chiller level) having a capacity of 600 TR (Minimum) at chilled water inlet / outlet temperature of 53.6 deg.F / 44.6 deg.F with suitable chilled water circulation rate and condenser water inlet / outlet temperature of 88 deg.F / 97 deg.F with suitable circulation rate, suitable for stepless continuous capacity from 100% to 20% at Constant Condenser Entering Temperature of 88 degF without surging , envelope stablity control & hot gas bypass , for operation on refrigerant R134a/Chlorine Free HFO Based. each comprising of the following complete as per specifications and as required. Maximum power consumption including VFD loss and loss due to passive harmoic filter at 100 % load (Kw/TR) 0.525 (at AHRI Condt.) & 0.572 (at Design Condt.) and NPLV : 0.35., COP 6.7 Fouling Factor for Evaporator & Condenser shall be 0.0005 & 0.001 FPS unit as per following specifications (from i-xx). Condenser pressure drop : 7.0 m WC Evaporator pressure drop: 7.0 m WC | ||
| 4 | Suitable no.& capacity of Semi Hermatic Centrifugal Two stage compression system compressor complete with automatic capacity control, safety switches, forced feed lubrication system etc. as per manufacturers specifications. | ||
| 5 | Suitable no & capacity squirrel cage induction motor totally enclosed refrigerant / air cooled type. Necessary insulation suitable for operation on 415 10% volts, 50 3% Hz , AC power supply. |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054