- Home
- >
- Tender
- >
- Gujarat Tender
- >
- Department of Military Engineer Services
- >
NTID 43022768
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowCorrigendum Addn Altn Upgrad in Kalol - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Corrigendum Addn Altn Upgrad" in Kalol, India.
- Opening Date : Thu 1st January, 2026
- Closing Date : Wed 24th December, 2025
- ₹ 2474000.00
- NTID 43022768
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
49800.00 -
Document Cost
500.00 -
Estimated Cost
2474000.00
Latest Corrigendum List
| # | Corrigendum Title | Corrigendum Type |
|---|---|---|
| 1 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum |
BOQ Items Total Items : 39 | Total Qty : 5036
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | M &L for tightening and fixing in position loose hanging copper / alurninium strip of any size on wall or building roof using new insulators of porceline of approved size and fixing existing copper / aluminium strip on the same as existing complete all as directed by Engineer-in-Charge. | 120.00 | RM |
| 2 | M&L for dismantling the strip from earth pit and testing of earth pit to be done as per fall of potential method mentioned in IS-3043 with digital earth resistance tester to check the healthiness of earthing system in and including replacement earth pit nut bolts with brass nut bolts as per required size and record should be kept on ledger duly signed by user representative, JE concerned and contractor and the same shall be submitted to Engr in charge for counter signature complete all as specified and directed by Engineer-in-Charge. Note: Testing of earth pit shall be done as required basis as directed by Engineer-in-Charge | 30.00 | EACH JOB |
| 3 | M &L for physical inspection for earthing health and to check the healthiness of earthing system whether the resistance under safe limits of resistance IF higher than the permissible then recharging of earthing should be done immediately with carbon based low resistivity compound 0.001 ohm meter recharging of existing earth pit by excavating soil up to electrode depth approx 10 feet by manual drilling (post hole) method and filling with backfill compound maintenance free earthing compound to achieve desired resistance value less than 1/3 ohms in and including water up to top of the excavated bore, backfilling of earth p t, measuring the value after refilling pit and testing of earthing after recharging, reconnecting grounding electrode conductor and earth grid applying petroleum jelly etc. to bolted joints to minimize corrosion for the pipe earthing or plate earthing then gel should be used to lower down the resistance complete all as specified and as directed by Engr-in-charge. Note: (i) In case of satisfactory results not found or results degraded during one year of recharging of the earthing, the same shall be made good/recharged again in order to have required test results within contract/Defect liability period without any extra cost to the department. (ii) Contractor will mark each earthing with CA No., date of recharging of earthing on MS sheet size 18"x12"x 1/8" with suitable mounting arrangement on wall or on ground duly painting blue over a coat of Red Oxide primer and letter/figures of words written with white colour. Quoted rate will be deemed to have been included the cost of the same. (iii) Necessary compound required for recharging shall be measured and paid separately under item No 4 here-in- after. | 106.00 | EACH SET |
| 4 | Supply and topup Earthing Soil Resistivity improvement compound Gel type, Enhancement compound Transparent Liquid Jel all as specified and directed by Engr-in-charge. | 2480.00 | KG |
| 5 | M&L for copper brazing (welding) at site to connect loop copper earthing strip of any size after tightening by nut, bolt, washer, check nuts of brass complete all as specified and as directed by Engr-in-charge. Note: Copper brazing shall be done upto 20 mtr height. Necessary tool/plant and ladder required for working upto 20 mtr height shall be deemed to be included in the rate quoted for above item. | 40.00 | EACH JOINT |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054