- Home
- >
- Tender
- >
- Rajasthan Tender
- >
- Department of Public Works Department
- >
NTID 42898529
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowAdditional Construction For Bl in Jaipur - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Additional Construction For Bl" in Jaipur, India.
- Opening Date : Thu 4th December, 2025
- Closing Date : Wed 3rd December, 2025
- ₹ 4209000.00
- NTID 42898529
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
84180.00 -
Document Cost
500.00 -
Estimated Cost
4209000.00
BOQ Items Total Items : 61 | Total Qty : 18309.5
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Anti termite treatment of floor using Imidacloprid 30.5% EC non repellent, odourless, low dose, environmentally safe terniticide with rapid action non corrosive stain free, by drilling 12mm diameter holes 300mm apart injecting the emulsion as per specification and plugging with cement mortar 1:2 ( 1 cement : 2 coarse sand) in the whole floor area DPE 12mm dia termitube system with required number of junction boxes are to be installed. The termitube will run all along the perimeter wall both inside and outside. In the middle area the termitube to be installed at an interval of 1.00 Mtr. or less both ways as required with sufficient number of junction boxes to pump the emulsion. After successful testing of termitube, pesticide emulsion of imidacloprid 30.5% EC mixed with water in the ration of 1:474 will be pumped by a motorized spray pump from the junction box in specified manner. The plinth area of the area treated will be measured for payment. | 50.00 | Sqm |
| 2 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils | 50.00 | Cum |
| 3 | Grading roof for water proofing treatment with water proffing compound Cement mortar 1:4 (1cement : 4 coarse sand) | 10.00 | Cum |
| 4 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated J or L hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-voilet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall confoim to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 5.0mm thick (Wt. 8.4 Kg./Mtr. Sq.) | 70.00 | Sqm |
| 5 | Providing and fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture as per direction of Engineer-in-charge of size 595 X 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanizing @120 grams per sqm) consisting of main T runner suitably spaced at joints to get required length and size of 24X38mm made from 0.33 mm thick (minimum) sheet, 1200mm centre to centre, and cross T of size 24X32mm made out of 0.33mm (Minimum) sheet, 1200mm long spaced between main T at 600mm centre to centre to form a grid of 1200X600mm and secondary cross T of length 600mm and size 24X32mm made out of 0.33 mm thick (Minimum) sheet to be interlocked at middle of the 1200X600mm panel to form grid of size 600X600mm resting ...on periphery walls/partitions on a perimeter wall angle pre-coated steel of size (24X24X3000mm made of 0.40mm thick (minimum) sheet with the help of rawl plugs at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval and laying 15mm thick densified edged calcium silicate ceiling tiles of approved texture in the grid including cutting /making opening for services like diffusers, grills, light fitting, fixtures, smoke detectors etc., wherever required, Main T runners to be suspended from ceiling using 50 mm long M 6 dash fasteners, 6mm G.I. fully threaded rods with galvnised steel L cleat level adjusters of size 80x25x2mm, spaced at 1200mm centre to centre long main T bottom exposed with 24mm of all T-sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawing and as directed by engineer-in-charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs)having area less than 0.30 Sqm. The calcium silicate ceiling tiles shall have NRC. Value 0.50 (Minimum), light reflection> 85% non-combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <= 0.043 w/m0KC. | 110.00 | Sqm |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054