Tender Result for Military Engineer Services - NRID 11104435
Military Engineer Services
Bathinda, Punjab, India
NRID 11104435
- AOC Date : Mon 10th July, 2023
- ₹ 185610613.65
- NRID 11104435
Provn Of Klp (phase-i) At Faridkot Mil Station - Lump Sum Price Worked Out By The Tenderer For Building /structure Works\" As Listed In Schedule A Section - I, Lump Sum Price Worked Out By The Tenderer For Internal Electrification Works\" As Listed In Schedule A Section - Ii (part-i), Sch \'a\' Sec - Ii (part-ii), (internal Electrification Works), Material And Labour For Concealed Point Wiring For One Light Point/fan Point /bell Point Controlled By One Switch (using Red, Black And Green Etc Colour Wires As Colour Coding) Complete With 1.5 Sqmm (nominal Cross Section Area) Single Core Frlsh Pvc Insulated Unsheathed And Multi Strand Copper Conductor Cable 1100 Volt (isi Marked) Drawn Through And Including Pvc Conduit 20mm Dia (medium Duty, Isi Marked) With All Fittings And All Accessories I.e. Pipe Bend, Pipe Hook, Elbow, Junction Boxes Etc., Including Pressed Steel Powder Coated Sunken Terminal Box (min 60mm Deep, Suitable Size) Concealed In Wall, Including 3mm Thick Bakelite Plastic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For Mounting Of Switches / Socket / Regulator Etc, Including Provn Of 1.5 Sqmm Single Core Frlsh Pvc Insulated Multi Strand Copper Conductor Wire Continues As Earth Wire Connected To Earth Dolly Etc. Including Cutting Chases In Wall And Making Good Disturbed Surfaces Of Walls/ceiling/floors Etc. By Using Cm (1:3) Complete All As Specified And As Directed. (switches/ Socket / Regulator Shall Be Measured And Paid Separately Under Appropriate Item Of Boq/sch \'a\')., All As Per Above Srl Item No. 04 But For One Socket Out Let 5 Amps Point Controlled By One Switch (on Same Board) Complete All As Specified And As Directed By Engineer-in-charge. (switches, Sockets Etc. Shall Be Measured And Paid Separately Under Appropriate Item Of Boq/sch A)., All As Per Above Srl Item No. 04 But For One Socket Out Let 5 Amps Point Controlled By One Switch (on Indipendent Board And Not Below The Any Other Switch Board) Complete All As Specified And As Directed By Engineer-in-charge. (switches , Sockets Etc. Shall Be Measured And Paid Separately Under Appropriate Item Of Boq/sch A)., Material And Labour For Concealed Point Wiring For One Light Point Controlled By Two Nos- Two Way Switch (using Red, Black And Green Colour Wires As Colour Coding) Complete With 1.5 Sqmm (nominal Cross Section Area) Single Core Frlsh Pvc Insulated Unsheathed And Multi Strand Copper Conductor Cable 1100 Volt (isi Marked) Drawn Through And Including Pvc Conduit 20mm Dia (medium Duty, Isi Marked) With All Fittings And All Accessories I.e. Pipe Bend, Pipe Hook, Elbow, Junction Boxes Etc., Including Pressed Steel Powder Coated Sunken Terminal Box (min 60mm Deep, Suitable Size) Concealed In Wall, Including 3mm Thick Bakelite Plastic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For Mounting Of Switches, Including Provn Of 1.5 Sqmm Single Core Frlsh Pvc Insulated Multi Strand Copper Conductor Wire Continues As Earth Wire Connected To Earth Dolly Etc. Including Cutting Chases In Wall And Making Good Disturbed Surfaces Of Walls/ceiling/floors Etc. By Using Cm (1:3) Complete All As Specified And As Directed. (switches Shall Be Measured And Paid Separately Under Appropriate Item Of Boq)., Material And Labour For Concealed Point Wiring For One Socket Out Let 15/16 Amps Point Controlled By One Switch (on Independant Board) (using Red, Black And Green Colour Wires As Colour Coding) Complete With 2.5 Sqmm (nominal Cross Section Area) Single Core Frlsh Pvc Insulated Unsheathed And Multi Strand Copper Conductor Cable 1100 Volt (isi Marked) Drawn Through And Including Pvc Conduit 20mm Dia (medium Duty, Isi Marked) With All Fittings And All Accessories I.e. Pipe Bend, Pipe Hook, Elbow, Junction Boxes Etc., Including Pressed Steel Powder Coated Sunken Terminal Box (min 60mm Deep, Suitable Size ) Concealed In Wall, Including 3mm Thick Bakelite Plastic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For Mounting Of Switches / Socket, Including Provn Of 2.5 Sqmm Single Core Frlsh Pvc Insulated Multi Strand Copper Conductor Wire Continues As Earth Wire Connected To Earth Dolly Etc. Including Cutting Chases In Wall And Making Good Disturbed Surfaces Of Walls/ceiling/floors Etc. By Using Cm (1:3) Complete All As Specified And As Directed. (switch, Socket Shall Be Measured And Paid Separately Under Appropriate Item Of Boq)., Material And Labour For Concealed Point Wiring For One Socket Out Let 15/16 Amps Point Controlled By One Switch (on Independant Board) (using Red, Black And Green Colour Wires As Colour Coding) Complete With 4 Sqmm (nominal Cross Section Area) Single Core Frlsh Pvc Insulated Unsheathed And Multi Strand Copper Conductor Cable 1100 Volt (isi Marked) Drawn Through And Including Pvc Conduit 20mm Dia (medium Duty, Isi Marked) With All Fittings And All Accessories I.e. Pipe Bend, Pipe Hook, Elbow, Junction Boxes Etc., Including Pressed Steel Powder Coated Sunken Terminal Box (min 60mm Deep, Suitable Size ) Concealed In Wall, Including 3mm Thick Bakelite Plastic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For Mounting Of Switches / Socket, Including Provn Of 4 Sqmm Single Core Frlsh Pvc Insulated Multi Strand Copper Conductor Wire Continues As Earth Wire Connected To Earth Dolly Etc. Including Cutting Chases In Wall And Making Good Disturbed Surfaces Of Walls/ceiling/floors Etc. By Using Cm (1:3) Complete All As Specified And As Directed. (switch, Socket Shall Be Measured And Paid Separately Under Appropriate Item Of Boq)., Supply And Fixing Switch Piano Flush Type (isi Marked), 5/6amps, Single Pole, Two Way (1 Module), Fixed On Laminated Sheet Complete All As Specified And As Directed By Engineer-in-charge. Note :- Cost Of Laminated Sheet Cover For Mounting Of Switch Is Included Under Respective Item Of Boq (point Wiring), Material And Labour For Concealed Point Wiring For One Light Point/fan Point /bell Point Controlled By One Switch (using Red, Black And Green Colour Wires As Colour Coding) Complete With 1.5 Sqmm (nominal Cross Section Area) Single Core Frlsh Pvc Insulated Unsheathed And Multi Strand Copper Conductor Cable 1100 Volt (isi Marked) Drawn Through And Including Pvc Conduit 20mm Dia (medium Duty, Isi Marked) With All Fittings And All Accessories I.e. Pipe Bend, Pipe Hook, Elbow, Junction Boxes Etc., Including Pressed Steel Powder Coated Sunken Terminal Box Suitable For Modular Switch Socket (min 60mm Deep, Suitable Size) Concealed In Wall, Including Inner And Outer Plates (cover Plate) Suitable For Fixing The Modular Switches/ Socket / Regulator Etc, Including Provn Of 1.5 Sqmm Single Core Frlsh Pvc Insulated Multi Strand Copper Conductor Wire Continues As Earth Wire Connected To Earth Dolly Etc. Including Cutting Chases In Wall And Making Good Disturbed Surfaces Of Walls/ceiling/floors Etc. By Using Cm (1:3) Complete All As Specified And As Directed. (switches/ Socket / Regulator Shall Be Measured And Paid Separately Under Appropriate Item Of Boq)., All As Per Above Srl Item No. 11 But For One Socket Out Let 5 Amps Point Controlled By One Switch (on Same Board) Complete All As Specified And As Directed By Engineer-in-charge. (switches, Sockets Etc. Shall Be Measured And Paid Separately Under Appropriate Item Of Boq/sch A)., All As Per Above Srl Item No. 11 But For One Socket Out Let 5 Amps Point Controlled By One Switch (on Independent Board And Not Below The Any Other Switch Board) Complete All As Specified And As Directed By Engineer-in-charge. (switches , Sockets Etc. Shall Be Measured And Paid Separately Under Appropriate Item Of Boq/sch A)., Material And Labour For Concealed Point Wiring For One Light Point Controlled By Two Nos- Two Way Switch (using Red, Black And Green Colour Wires As Colour Coding) Complete With 1.5 Sqmm (nominal Cross Section Area) Single Core Frlsh Pvc Insulated Unsheathed And Multi Strand Copper Conductor Cable 1100 Volt (isi Marked) Drawn Through And Including Pvc Conduit 20mm Dia (medium Duty, Isi Marked) With All Fittings And All Accessories I.e. Pipe Bend, Pipe Hook, Elbow, Junction Boxes Etc., Including Pressed Steel Powder Coated Sunken Terminal Box Suitable For Modular Switch Socket (min 60mm Deep, Suitable Size ) Concealed In Wall, Including Inner And Outer Plates (cover Plate) Suitable For Fixing The Modular Switch, Including Provn Of 1.5 Sqmm Single Core Frlsh Pvc Insulated Multi Strand Copper Conductor Wire Continues As Earth Wire Connected To Earth Dolly Etc. Including Cutting Chases In Wall And Making Good Disturbed Surfaces Of Walls/ceiling/floors Etc. By Using Cm (1:3) Complete All As Specified And As Directed. (switches Shall Be Measured And Paid Separately Under Appropriate Item Of Boq)., Material And Labour For Concealed Point Wiring For One Socket Out Let 15/16 Amps Point Controlled By One Switch (on Independant Board) (using Red, Black And Green Colour Wires As Colour Coding) Complete With 2.5 Sqmm (nominal Cross Section Area) Single Core Frlsh Pvc Insulated Unsheathed And Multi Strand Copper Conductor Cable 1100 Volt (isi Marked) Drawn Through And Including Pvc Conduit 20mm Dia (medium Duty, Isi Marked) With All Fittings And All Accessories I.e. Pipe Bend, Pipe Hook, Elbow, Junction Boxes Etc., Including Pressed Steel Powder Coated Sunken Terminal Box Suitable For Modular Switch Socket (min 60mm Deep, Suitable Size ) Concealed In Wall, Including Inner And Outer Plates (cover Plate) Suitable For Fixing The Modular Switches / Socket, Including Provn Of 2.5 Sqmm Single Core Frlsh Pvc Insulated Multi Strand Copper Conductor Wire Continues As Earth Wire Connected To Earth Dolly Etc. Including Cutting Chases In Wall And Making Good Disturbed Surfaces Of Walls/ceiling/floors Etc. By Using Cm (1:3) Complete All As Specified And As Directed. (switch, Socket Shall Be Measured And Paid Separately Under Appropriate Item Of Boq)., Material And Labour For Concealed Point Wiring For One Socket Out Let 15/16 Amps Point Controlled By One Switch (on Independant Board) (using Red, Black And Green Colour Wires As Colour Coding) Complete With 4 Sqmm (nominal Cross Section Area) Single Core Frlsh Pvc Insulated Unsheathed And Multi Strand Copper Conductor Cable 1100 Volt (isi Marked) Drawn Through And Including Pvc Conduit 25mm Dia (medium Duty, Isi Marked) With All Fittings And All Accessories I.e. Pipe Bend, Pipe Hook, Elbow, Junction Boxes Etc., Including Pressed Steel Powder Coated Sunken Terminal Box Suitable For Modular Switch Socket (min 60mm Deep, Suitable Size ) Concealed In Wall, Including Inner And Outer Plates (cover Plate) Suitable For Fixing The Modular Switches / Socket, Including Provn Of 4 Sqmm Single Core Frlsh Pvc Insulated Multi Strand Copper Conductor Wire Continues As Earth Wire Connected To Earth Dolly Etc. Including Cutting Chases In Wall And Making Good Disturbed Surfaces Of Walls/ceiling/floors Etc. By Using Cm (1:3) Complete All As Specified And As Directed. (switch, Socket Shall Be Measured And Paid Separately Under Appropriate Item Of Boq)., Supply And Hanging /fixing Ceiling Fan 1200 Mm Sweep Ac Supply (input Voltage Range ; 120 To 280v), Bldc Type, 5 Star Rated, Bee And Isi Marked Super Enamelled, Copper Winding Of \'b\' Class Insulation, Single Phase, Minimum 30w ( 10%), Temperature Rise 40 Degree Maximum Without Remote With And Including Capacitive Regulator, 03 No Blades, Down Rod Including Accessories, White Colour, Total Harmonic Less Than 10%, 5 Speed, Hanging In Position Including Making Connection With Flexible Cord Three Core Twisted Copper Conductor Of Suitable Size From Ceiling Rose To Fan Complete All As Specified. Note :- (i) Serial Number As Issued By Engr-in-charge Of Celing Fan And Ge Office Name Shall Also Be Written On Fan With Red Colour Permanent Marker And Fixing Of Regulator On Switch Board, Cost For The Same Shall Deemed To Be Included In The Quoted Unit Rate Nothing Extra Shall Be Paid On This Account, Supply And Fixing Exhaust Fan (heavy Duty) Steel Body, Ac Single Phase 230v, 50 Cycle Per Second, Size 300mm Sweep With Blades And Frame Including Self Closing Gi Louvers Off Mode Protection Against Birds Etc Mounted In Suitable Opening Arrangement In Wall And Connecting Up And Including Three Core Pvc Insulated Pvc Sheathed Copper Conductor Flexible Cable 24/0.2mm Drawn In Flexible Pvc Conduit And Hanging On Wall With 4 Nos Steel Fastners 10mm Dia 100mm Long And Making Good The Disturbed Surface Complete All As Specified And As Directed By Engineer-in-charge. Note :- (i) Serial Number As Issued By Engr-in-charge Of Fan And Ge Office Name Shall Also Be Written On Fan With Red Colour Permanent Marker, Cost For The Same Shall Deemed To Be Included In The Quoted Unit Rate Nothing Extra Shall Be Paid On This Account, Supply And Fixing Exhaust Fan (heavy Duty) Steel Body, Ac Single Phase 230v, 50 Cycle Per Second, Size 450mm Sweep With Blades And Frame Including Self Closing Gi Louvers Off Mode Protection Against Birds Etc Mounted In Suitable Opening Arrangement In Wall And Connecting Up And Including Three Core Pvc Insulated Pvc Sheathed Copper Conductor Flexible Cable 24/0.2mm Drawn In Flexible Pvc Conduit And Hanging On Wall With 4 Nos Steel Fastners 10mm Dia 100mm Long And Making Good The Disturbed Surface Complete All As Specified And As Directed By Engineer-in-charge. Note :- (i) Serial Number As Issued By Engr-in-charge Of Fan And Ge Office Name Shall Also Be Written On Fan With Red Colour Permanent Marker, Cost For The Same Shall Deemed To Be Included In The Quoted Unit Rate Nothing Extra Shall Be Paid On This Account, Supply And Fixing Air Circulator Heavy Duty Wall Mounting 450 Mm Sweep , 240 Volt, Single Phase Isi Marked With Built In Selector Switch Including Making Connection By Using Three Core Pvc Insulated Pvc Sheathed Copper Conductor Flexible Cable 24/0.2mm From Ceiling Rose To Air Circulator Complete All As Specified And As Directed By Engineer-in-charge. Note:- (i) The Air Circulator Is To Be Fixed On Wall With All Necessary T & P And Other Accessories Required Shall Be Deemed To Be Included In The Above Item No Extra Payment Will Be Admissiable On This Account. (ii) Serial Number As Issued By Engr-in-charge Of Fan And Ge Office Name Shall Also Be Written On Air Circulator With Red Colour Permanent Marker, Cost For The Same Shall Deemed To Be Included In The Quoted Unit Rate Nothing Extra Shall Be Paid On This Account., Supply And Fixing Air Freshner Fan, 250 Mm Sweep Heavy Plastic Body, 240 Volts Complete With Lovers Shutters And Mounted In Suitable Opening Arrangement In Wall And Connecting Up And Including Three Core Pvc Insulated Pvc Sheathed Copper Conductor Flexible Cable 24/0.2mm Drawn In Flexible Pvc Conduit And Hanging On Wall With 4 Nos Steel Fastners 10mm Dia 100mm Long And Making Good The Disturbed Surface Complete All As Specified And As Directed By Engineer-in-charge. Note:- (i) Serial Number As Issued By Engr-in-charge Of Fan And Ge Office Name Shall Also Be Written On Fan With Red Colour Permanent Marker, Cost For The Same Shall Deemed To Be Included In The Quoted Unit Rate Nothing Extra Shall Be Paid On This Account., Supply And Fixing (concealed In Wall Or As Directed) Single Pole And Neutral Sheet Metal Enclosure (ac Box) With A Two Pin And Earth Plug And Socket Complete With One Single Pole Mcb Of Capacity 20 Amps, 240 Volts, Ac Supply Complete All As Specified And Directed By Engineer-in-charge., Supply And Fixing (concealed Flush To Wall) Factory Made Db (made Out Of Crca Sheet Not Less Than 1.2mm Thick, Fitted With Din Channel Neutral Link And 250 Amp Rated Bus Bar) Vtpn, 4 Way 415v, Suitable For Mounting Mccb/mcb, Conforming To Is-13032, Db Shall Be Semi Glosy Finished With Epoxy Polyster Based Powder Paint Sprayed And Backed At High Temperature Between Powder Paint Process To Ensure Smooth Finish And Protection Against Corrosion Atmosphere. The Db Shall Be Double Door Type With Hinged Door With Locking Arrangement, The Dbs Shall Be Same Make As Mcbs, Db Shall Be Provided With Level Marking Indicating The Incoming And Outgoing Circuits On Always As Specified. The Dbs Shall Be Of Ip-43 Protection Class, And Including Making Good Disturbed Surfaces Of Walls As Necessaty Complete All As Specified And Directed By Engineer-in-charge. Note :- Mccb/mcb Shall Be Measured And Paid Separately Under Appropriate Item Of Boq., Supply And Fixing (concealed Flush To Wall) Factory Made Db (made Out Of Crca Sheet Not Less Than 1.2mm Thick, Fitted With Din Channel Neutral Link And 200 Amp Rated Bus Bar) Tpn, 4 Way 415v, Suitable For Mounting Mcb/isolator Etc, Conforming To Is-13032, Db Shall Be Semi Glosy Finished With Epoxy Polyster Based Powder Paint Sprayed And Backed At High Temperature Between Powder Paint Process To Ensure Smooth Finish And Protection Against Corrosion Atmosphere. The Db Shall Be Double Door Type With Hinged Door With Locking Arrangement, The Dbs Shall Be Same Make As Mcbs, Db Shall Be Provided With Level Marking Indicating The Incoming And Outgoing Circuits On Always As Specified. The Dbs Shall Be Of Ip-43 Protection Class, And Including Making Good Disturbed Surfaces Of Walls As Necessaty Complete All As Specified And Directed By Engineer-in-charge. Note :- Mcb/isolator Etc Shall Be Measured And Paid Separately Under Appropriate Item Of Boq., Supply And Fixing (concealed Flush To Wall) Factory Made Db (made Out Of Crca Sheet Not Less Than 1.2mm Thick, Fitted With Din Channel Neutral Link And 200 Amp Rated Bus Bar) Tpn, 8 Way 415v, Suitable For Mounting Mcb/isolator Etc, Conforming To Is-13032, Db Shall Be Semi Glosy Finished With Epoxy Polyster Based Powder Paint Sprayed And Backed At High Temperature Between Powder Paint Process To Ensure Smooth Finish And Protection Against Corrosion Atmosphere. The Db Shall Be Double Door Type With Hinged Door With Locking Arrangement, The Dbs Shall Be Same Make As Mcbs, Db Shall Be Provided With Level Marking Indicating The Incoming And Outgoing Circuits On Always As Specified. The Dbs Shall Be Of Ip-43 Protection Class, And Including Making Good Disturbed Surfaces Of Walls As Necessaty Complete All As Specified And Directed By Engineer-in-charge. Note :- Mcb/isolator Etc Shall Be Measured And Paid Separately Under Appropriate Item Of Boq., Supply And Fixing (concealed Flush To Wall) Factory Made Db (made Out Of Crca Sheet Not Less Than 1.2mm Thick, Fitted With Din Channel Neutral Link And 200 Amp Rated Bus Bar) Spn, 12 Way 240v, Suitable For Mounting Mcb/isolator Etc, Conforming To Is-13032, Db Shall Be Semi Glosy Finished With Epoxy Polyster Based Powder Paint Sprayed And Backed At High Temperature Between Powder Paint Process To Ensure Smooth Finish And Protection Against Corrosion Atmosphere. The Db Shall Be Double Door Type With Hinged Door With Locking Arrangement, The Dbs Shall Be Same Make As Mcbs, Db Shall Be Provided With Level Marking Indicating The Incoming And Outgoing Circuits On Always As Specified. The Dbs Shall Be Of Ip-43 Protection Class, And Including Making Good Disturbed Surfaces Of Walls As Necessaty Complete All As Specified And Directed By Engineer-in-charge. Note :- Mcb/isolator Etc Shall Be Measured And Paid Separately Under Appropriate Item Of Boq., Supply And Fixing (concealed Flush To Wall) Factory Made Db (made Out Of Crca Sheet Not Less Than 1.2mm Thick, Fitted With Din Channel Neutral Link And 200 Amp Rated Bus Bar) Spn, 8 Way 240v, Suitable For Mounting Mcb/isolator Etc, Conforming To Is-13032, Db Shall Be Semi Glosy Finished With Epoxy Polyster Based Powder Paint Sprayed And Backed At High Temperature Between Powder Paint Process To Ensure Smooth Finish And Protection Against Corrosion Atmosphere. The Db Shall Be Double Door Type With Hinged Door With Locking Arrangement, The Dbs Shall Be Same Make As Mcbs, Db Shall Be Provided With Level Marking Indicating The Incoming And Outgoing Circuits On Always As Specified. The Dbs Shall Be Of Ip-43 Protection Class, And Including Making Good Disturbed Surfaces Of Walls As Necessaty Complete All As Specified And Directed By Engineer-in-charge. Note :- Mcb/isolator Etc Shall Be Measured And Paid Separately Under Appropriate Item Of Boq., Supply And Fixing (concealed Flush To Wall) Factory Made Db (made Out Of Crca Sheet Not Less Than 1.2mm Thick, Fitted With Din Channel Neutral Link And 200 Amp Rated Bus Bar) Spn, 4 Way 240v, Suitable For Mounting Mcb/isolator Etc, Conforming To Is-13032, Db Shall Be Semi Glosy Finished With Epoxy Polyster Based Powder Paint Sprayed And Backed At High Temperature Between Powder Paint Process To Ensure Smooth Finish And Protection Against Corrosion Atmosphere. The Db Shall Be Double Door Type With Hinged Door With Locking Arrangement, The Dbs Shall Be Same Make As Mcbs, Db Shall Be Provided With Level Marking Indicating The Incoming And Outgoing Circuits On Always As Specified. The Dbs Shall Be Of Ip-43 Protection Class, And Including Making Good Disturbed Surfaces Of Walls As Necessaty Complete All As Specified And Directed By Engineer-in-charge. Note :- Mcb/isolator Etc Shall Be Measured And Paid Separately Under Appropriate Item Of Boq., Supply And Fixing Rcbo Of Capacity 100 Amp, Tpn, 300ma, 415 Volt, Breaking Capacity 10ka , Fixed Thermal Magnetic, Including Thimbles, Nuts, Washers Etc , Including Making Incoming, Outgoing Connections Complete All As Specified And As Directed By Engineer-in-charge., Supply And Fixing Rcbo Of Capacity 63 Amp, Tpn, 300ma, 415 Volt, Breaking Capacity 10ka , Fixed Thermal Magnetic, Including Thimbles, Nuts, Washers Etc , Including Making Incoming, Outgoing Connections Complete All As Specified And As Directed By Engineer-in-charge., Supply And Fixing Rcbo Of Capacity 40 Amp, Fp, 100ma, 415 Volt, Breaking Capacity 10ka , Fixed Thermal Magnetic, Including Thimbles, Nuts, Washers Etc , Including Making Incoming, Outgoing Connections Complete All As Specified And As Directed By Engineer-in-charge., Supply And Fixing Mccb Of Capacity 100 Amp, Tpn, 415 Volt, Short Circuit Breaking Capacity 16ka , Fixed Thermal Magnetic Trip, Setting 80-100%, Icu-100% Ics Confirming To Iec-947, Is-13947, Including Thimbles, Nuts, Bolts, Washers Etc, Including Making Incoming, Outgoing Connections Complete All As Specified And As Directed By Engineer-in-charge ., Supply And Fixing Mcb B Curve Suitable For 230 Volts Ac Supply, 40 Amps, Spn With Over Load And Short Circuit Protection And Rupturing Capacity Not Less Than 10 Ka, Fixing In Db Complete All As Specified And As Directed By Engineer-in-charge, Supply And Fixing Mcb B Curve Suitable For 230 Volts Ac Supply, 32 Amps, Spn With Over Load And Short Circuit Protection And Rupturing Capacity Not Less Than 10 Ka, Fixing In Db Complete All As Specified And As Directed By Engineer-in-charge, Supply And Fixing Mcb B Curve Suitable For 230 Volts Ac Supply, 20 Amps, Spn With Over Load And Short Circuit Protection And Rupturing Capacity Not Less Than 10 Ka, Fixing In Db Complete All As Specified And As Directed By Engineer-in-charge, Supply And Fixing Mcb B Curve Suitable For 230 Volts Ac Supply, 10 Amps, Spn With Over Load And Short Circuit Protection And Rupturing Capacity Not Less Than 10 Ka, Fixing In Db Complete All As Specified And As Directed By Engineer-in-charge, Supply And Fixing Mcb B Curve Suitable For 230 Volts Ac Supply, 06 To 32 Amps, Sp With Over Load And Short Circuit Protection And Rupturing Capacity Not Less Than 10 Ka, Fixing In Db Complete All As Specified And As Directed By Engineer-in-charge, Supply And Fixing Mcb B Curve Suitable For 230 Volts Ac Supply, 40 Amps, Sp With Over Load And Short Circuit Protection And Rupturing Capacity Not Less Than 10 Ka, Fixing In Db Complete All As Specified And As Directed By Engineer-in-charge, Supply And Fixing Blanking Plate Suitable For Any Type Of Db Complete All As Specified And As Directed By Engineer-in-charge., Material And Labour For Concealed Sub Main Wiring (using Colour Coding Such As Red, Black, White, Green Colour Or As Directed) With 16 Sqmm Single Core (05 Run I.e 4 Runs For Main 3 Phase And Neutral, 01 Run For Continues As Earth Wire) Frlsh Pvc Insulated Unsheathed Multistrand Copper Conductor Cable Drawn Through And Including Pvc Conduit 25mm Dia (medium Quality Isi Marked), For Independent Circuit Including All Fitting Arrangement I.e. Pvc Clamp, Rawl Plug, Screw, Pvc Junction Box, Tee, Bend Etc. And Including Cutting Of Chases In Wall And Making Good Disturbed Surfaces Of Walls As Per Original Complete All As Specified And As Directed. Note :- Five Runs Of Copper Conductor Cable And One Run Of Pvc Conduit Including Accessories Shall Be Measured And Paid As One Unit (one Rm Length) For Payment And Extra Length Of Cables Required For Connection To Mcbs/db Shall Not Be Measured And The Cost For The Same Shall Deemed To Be Included In The Unit Rate., Material And Labour For Concealed Sub Main Wiring (using Colour Coding Such As Red, Black, White, Green Colour Or As Directed) With 10 Sqmm Single Core (05 Run I.e 4 Runs For Main 3 Phase And Neutral, 01 Run For Continues As Earth Wire) Frlsh Pvc Insulated Unsheathed Multistrand Copper Conductor Cable Drawn Through And Including Pvc Conduit 25mm Dia (medium Quality Isi Marked), For Independent Circuit Including All Fitting Arrangement I.e. Pvc Clamp, Rawl Plug, Screw, Pvc Junction Box, Tee, Bend Etc. And Including Cutting Of Chases In Wall And Making Good Disturbed Surfaces Of Walls As Per Original Complete All As Specified And As Directed. Note :- Five Runs Of Copper Conductor Cable And One Run Of Pvc Conduit Including Accessories Shall Be Measured And Paid As One Unit (one Rm Length) For Payment And Extra Length Of Cables Required For Connection To Mcbs/db Shall Not Be Measured And The Cost For The Same Shall Deemed To Be Included In The Unit Rate., Material And Labour For Concealed Sub Main Wiring (using Colour Coding Such As Red, Black, White, Green Colour Or As Directed) With 6 Sqmm Single Core (03 Run I.e 2 Runs For Main Phase And Neutral, 01 Run For Continues As Earth Wire) Frlsh Pvc Insulated Unsheathed Multistrand Copper Conductor Cable Drawn Through And Including Pvc Conduit 25mm Dia (medium Quality Isi Marked), For Independent Circuit Including All Fitting Arrangement I.e. Pvc Clamp, Rawl Plug, Screw, Pvc Junction Box, Tee, Bend Etc. And Including Cutting Of Chases In Wall And Making Good Disturbed Surfaces Of Walls As Per Original Complete All As Specified And As Directed. Note :- Three Runs Of Copper Conductor Cable And One Run Of Pvc Conduit Including Accessories Shall Be Measured And Paid As One Unit (one Rm Length) For Payment And Extra Length Of Cables Required For Connection To Mcbs/db Shall Not Be Measured And The Cost For The Same Shall Deemed To Be Included In The Unit Rate., Material And Labour For Concealed Sub Main Wiring (using Colour Coding Such As Red, Black, White, Green Colour Or As Directed) With 4 Sqmm Single Core (03 Run I.e 2 Runs For Main Phase And Neutral, 01 Run For Continues As Earth Wire) Frlsh Pvc Insulated Unsheathed Multistrand Copper Conductor Cable Drawn Through And Including Pvc Conduit 25mm Dia (medium Quality Isi Marked), For Independent Circuit Including All Fitting Arrangement I.e. Pvc Clamp, Rawl Plug, Screw, Pvc Junction Box, Tee, Bend Etc. And Including Cutting Of Chases In Wall And Making Good Disturbed Surfaces Of Walls As Per Original Complete All As Specified And As Directed. Note :- Three Runs Of Copper Conductor Cable And One Run Of Pvc Conduit Including Accessories Shall Be Measured And Paid As One Unit (one Rm Length) For Payment And Extra Length Of Cables Required For Connection To Mcbs/db Shall Not Be Measured And The Cost For The Same Shall Deemed To Be Included In The Unit Rate., Supply And Fixing Led Lamp Minimum 3 Star Rated 9w Led B-22 Base Complete All As Specified And Directed By Engr-in-charge With Following Specifications (a) Lumen System Efficacy Of Lamp Should Be Minimum 100 Lumen Per Watt. (b) Input Voltage Range : 140 To 270 Volts (c) Temp Operating Range : Minus 10 C To Plus 45 C (d) Power Factor : Minimum 0.95 (e) Cri : More Than 70, Supply And Fixing Led Complete Fitting Including Batten, T-8 Retro Led Polycarbonate 1 X 20 Watt, Appx 4 Feet Long, Environment Friendly, Including Electric Connection With Using 2 Core Flexible Copper Conductor Cable 23/0.00076 From Ceiling Rose To Tube Fitting, Complete Fitting With All Accessories And Following Specifications, Complete All As Specified And Directed By Engineer-in-charge :- (a) Lumen System Efficacy Of Luminaire Should Be Minimum 100 Lumen Per Watt. (b) Input Voltage Range : 140 To 270 Volts. (c) Temp Operating Range : Minus 10 C To Plus 45 C (d) Power Factor : Minimum 0.95 (e) Thd : Max10%. (f) Ip Rating : Ip-20. (g) Crca Pre Coated Housing With Two Coloured Plastic End Cap. (h) Led Driver Of The Same Make As Of The Luminaire. (j) Led Driver Should Be Complete With All Protections Viz Open/short Circuit Protection, Over Voltage Protection, All As Per Standard Design Of Manufacturer. (k) Surge Protection Minimum 2.5 Kv. (l) Cct : 6500k (m) Cri : Morethan 80 (n) Rated Life Time : 50000 Burning Hrs (average 10 To 12 Hrs Daily), Supply And Fixing Led Light Fitting 1 X 10 Watt, Appx 2 Feet Long Environment Friendly, Including Electric Connection With Using 2 Core Flexible Copper Conductor Cable 23/0.00076 From Ceiling Rose To Light Fitting, Complete Fitting With All Accessories And Following Specifications, Complete All As Specified And Directed By Engineer-in-charge :- (a) Lumen System Efficacy Of Luminaire Should Be Minimum 100 Lumen Per Watt. (b) Input Voltage Range : 140 To 270 Volts (c) Temp Operating Range : Minus 10 C To Plus 45 C (d) Power Factor : Minimum 0.95 (e) Thd : Max 10%. (f) Ip Rating : Ip-20. (g) Crca Pre Coated Housing With Two Coloured Plastic End Cap. (h) Led Driver Of The Same Make As Of The Luminaire. (j) Led Driver Should Be Complete With All Protections Viz Open/short Circuit Protection, Over Voltage Protection, All As Per Standard Design Of Manufacturer. (k) Surge Protection Minimum 2.5 Kv. (l) Cct : 6500k (m) Cri : More Than 80 (n) Rated Life Time : 50000 Burning Hrs (average 10 To 12 Hrs Daily), Supply And Fixing Led Light Fitting 1 X 18 Watt, 1 Ft X 1 Ft, Ceiling Surface Type Environment Friendly, Including Electric Connection With Using 2 Core Flexible Copper Conductor Cable 23/0.00076 From Ceiling Rose To Light Fitting, Complete Fitting And All Accessories With Following Specifications And All As Directed:- (a) Lumen System Efficacy Of Luminaire Should Be Minimum 100 Lumen Per Watt. (b) Input Voltage Range : 140 To 270 Volts (c) Temp Operating Range : Minus 10 C To Plus 45 C (d) Power Factor : Minimum 0.95 (e) Thd : Max10%. (f) Ip Rating : Ip20. (g) Cct : 6500k (h) Cri : Morethan 80 (j) Crca Pre Coated Housing. (k) Led Driver Of The Make As Of The Luminaire. (l) Led Driver Should Be Complete With All Protections Viz Open/short Circuit Protection, Over Voltage Protection, All As Per Standard Design Of Manufacturer. (m) Surge Protection Minimum 2.5 Kv. (n) Rated Life Time : 50000 Burning Hrs (average 10 To 12 Hrs Daily), Supply And Fixing Energy Efficient Led Street Light Fitting Of 25w Pressure Die Cast Aluminium Housing/body, Heat Resistant Clear Toughened Glass, Better Optics For Uniform Distribution Street/roadway Luminaire, With Driver, Including Electric Connection With Using 2 Core Flexible Copper Conductor Cable 1sqmm From Ceiling Rose To Light Fitting, Fixing The Light Fitting With New Bracket Made Out Of Gi Tubing Light Grade 25mm Dia, 1.2 Metre Long Bent To Shape At 120 Degree Angle At Half Metre From Bottom, Including Two Nos Clamps Made Out Of Ms Flat Iron Size 25x3 Mm With Suitable Nuts And Bolts For Fixing Of Bracket Including Painting To Ms Clamp And Nut Bolts With Two Coats Of Aluminium Paint Over A Coat Of Red Oxide Primer, Complete Fitting With All Accessories And Following Specifications, Complete All As Specified And Directed By Engineer-in-charge :- (a) Lumen System Efficacy Of Luminaire Should Be Minimum 100 Lumen Per Watt. (b) Input Voltage Range : 140 To 270 Volts (c) Temp Operating Range : Minus 10 C To Plus 50 C (d) Power Factor : Minimum 0.95 (e) Thd : Max10%. (f) Ip Rating : Ip65. (g) Ik Rating : Minimum Ik07 (h) Built In Potted Led Driver Of The Make As Of The Luminaire. (j) Led Driver Should Be Complete With All Protections Viz Open/short Circuit Protection, Over Voltage Protection, All As Per Standard Design Of Manufacturer. (k) Surge Protection 10 Kv (inbuilt + Extended) (l) Cct : 5700 K. (m) Cri : Morethan 70 (n) Lens - High Efficiency Wide Angle Lens. (o) Bis Approved Fixtures And Driver (p) Rated Life Time : 50000 Burning Hrs (average 10 To 12 Hrs Daily), Material And Labour For Concealed Wiring For Tv Antenna Connection Complete With Coaxial Rg-6 Heavy Duty Pvc Insulated Sheathed Cable With Copper Conductor Having Single Strand Of 0.7 Mm Dia And A Aluminium Wire Net Drawn Through And Including Pvc Conduit 25mm Dia (medium Duty, Isi Marked) With All Fittings And All Accessories I.e. Pipe Bend, Pipe Hook, Elbow, Junction Boxes Etc., Including Cutting Chases In Wall And Making Good Disturbed Surfaces Of Walls/ceiling/floors Etc. By Using Cm (1:3) Complete All As Specified And As Directed. (tv Antenna Connection Socket Outlet, Terminal Box Shall Be Measured And Paid Separately Under Appropriate Item Of Boq)., Material And Labour For Pressed Steel Powder Coated Sunken Terminal Box Of Size 100mm X100mmx50mm Concealed In Wall, Including Inner And Outer Plates (cover Plate) Suitable For Fixing And Including Modular Type (1 Module) 2 Pin Tv Antenna Connection Socket Outlet Round Flush Type Duly Marked With Symbol Of Tv And Making Good Disturbed Surfaces Of Walls By Using Cm (1:3) Complete All As Specified And As Directed., Material And Labour For Concealed Wiring For Telephone Connection Complete With Pvc Insulated Sheathed Cable With Copper Conductor Having Single Strand Of 0.4 Mm Dia Two Pair Taped For Telephone Wiring Drawn Through And Including Pvc Conduit 20mm Dia (medium Duty, Isi Marked) With All Fittings And All Accessories I.e. Pipe Bend, Pipe Hook, Elbow, Junction Boxes Etc., Including Cutting Chases In Wall And Making Good Disturbed Surfaces Of Walls/ceiling/floors Etc. By Using Cm (1:3) Complete All As Specified And As Directed. (telephone Connection Socket Outlet And Terminal Box Shall Be Measured And Paid Separately Under Appropriate Item Of Boq)., Material And Labour For Pressed Steel Powder Coated Sunken Terminal Box Of Size 100mm X100mmx50mm Concealed In Wall, Including Inner And Outer Plates (cover Plate) Suitable For Fixing And Including Modular Type (1 Module) Telephone Connection Socket Outlet Flush Type Duly Marked With Symbol Of Telephone And Making Good Disturbed Surfaces Of Walls By Using Cm (1:3) Complete All As Specified And As Directed., Subtotal, Lump Sum Price Worked Out By The Tenderer For Internal Water Supply Works\" As Listed In Schedule A Section - Iii (part-i), Sch \'a\' Sec - Iii (part-ii), (internal Water Supply Works), Supply And Fixing Hand Shower (health Faucet) Fancy Type, Cp Including 1.2 Meter Long 8mm Dia Flexible Tube And Including Wall Hook And Fixing Material Complete All As Specified And As Directed By Engineer-in-charge., Subtotal, Lump Sum Price Worked Out By The Tenderer For Hard Standing Work\" As Listed In Schedule A Section -iv, Lump Sum Price Worked Out By The Tenderer For Road, Path & Culvert Work\" As Listed In Schedule A Section -v (part-i), Sch \'a\' Sec - V (part-ii), (road, Path & Culvert Work), Material And Labour For 150mm Thick Wmm In Two Layers (compacted Thickness) Wet Mix Macadam Manufactured In Wmm Plant., With Crushed Stone Aggregates Specified Grading, Spreading Using Sensor Paver And Consolidated To Reqd Gradient And Camber Complete All As Specified And Directed., Supply And Laying/fixing 60 Mm Thick (m-35 Grade) Precast Interlocking Tile/paving Block Factory Casted (made By Using Pvc/ Rubber Moulds On Vibrating Table Machine) Using Grey Cement And No Pigment, Any Shape Haxagon / Trigular / Zigzag / I-shaped Etc, As Directed, Confirming To Relevant Is, Laid Over And Including 25mm Thick Layer Of Sand Cushining And Filling The Interstices Etc With Sand Complete All As Specified And As Directed., Supply And Laying/fixing 80 Mm Thick (m-40 Grade) Precast Interlocking Tile/paving Block Factory Casted (made By Using Pvc/ Rubber Moulds On Vibrating Table Machine) Using Grey Cement And No Pigment, Any Shape Haxagon / Trigular / Zigzag / I-shaped Etc, As Directed, Confirming To Relevant Is, Laid Over And Including 25mm Thick Layer Of Sand Cushining And Filling The Interstices Etc With Sand Complete All As Specified And As Directed., Supply And Laying Factory Made Kerb Stone Of M-25 Grade Cement Concrete Laid In Position To The Required Line, Level And Curvature, Jointed With Cement Mortar (1:3) (1 Cement:3 Coarse Sand), Including Making Joints With Or Without Grooves (thickness Of Joints Except At Sharp Curve Shall Not To More Than 5mm), Including Making Drainage Opening Wherever Required Complete All As Specified And As Directed., Material And Labour For Thermo Plastic Paint Road Marking 2mm Thick Painting (lines, Dashes, Arrows, Letters Etc) With Road Safety Spikeries Glass Beads @ 8% By Weight Including Preparation Of New Or Previously Treated Road Surfaces And Applying Paint By Using Special Applicator Machine With Heating Arrangement Complete All As Specified And As Directed., Supply And Fixing Metal Tubular Delineator Made Out Of Abs Round Body Fitted With 02 Nos 65mm Dia Highly Reflective Reflectors Made Out Of Pmma And Mounted On 45/50mm Dia Mild Steel Pipe 600mm Height Duly Podwer Coated And Thermo Plastic Elastomer 3 Bands Of Green, Red And Yellow Reflector Radium Tape Of 25mm Wide Strips With Anti Theft Steel Net For Reflector Protection Including Embedding In Pcc (1:2:4, Type B1) Block Size 150x150x300mm Including Necessary Earthwork Complete All As Specified And As Directed., Supply And Fixing Road Stud Cat Eye Solar Reflective Type Of Metal Body Alloy Of Size 100mmx 100mm X 20 Mm With Pmma Striplens Reflector And Fixing The Same On Road Surface By Applying Approximately 100 Gm Epoxy Mixture And Placing The Cat Eye Without Applying Exessive Pressure And Additional Fixed With Zinc Plated Steel Nail Of Suitable Size As Per Manufacturers Instructions At The Centre Of Cat Eye Complete All As Specified And As Directed. Make Dark Eye / 3m/ Greenlite), Supply And Fixing Convex Safety Mirror Of 1000 Mm Dia Made From Long Life Poly Carbonate With Strong Impact Resistant And Shattle Proof Fitted With A Sun Shield Or Protective Hood Of Colour As Approved, Provided With Suitable Ms Pipe Post (1.5m Height Excluding Embedded Portion) Duly Coated With Synthetic Enamel Paint Over A Coat Of Red Oxide Primer, Including Embedding In Pcc (1:2:4, Type B1) Block Size 450x450x450mm Including Necessary Earthwork Complete All As Specified And As Directed. Make Dark Eye / 3m/ Greenlite, Supply And Fixing Solar Road Stud Having 3 Led Of Colour Red/yellow To A Side (total 6 Nos) Housed In A Tough Pressure Die Casted Aluminium Alloy Of Size 125 X 125mm Or 120 X 130mm With Built In Stem Of Suitable Length For Fixing With Epoxy, Leds Solar Cells Battery & Light Sensor Well Protected Inside Under Tough Unbreakable Polycarbonate Transparent Sheet Top System, Workable For 3-4 Days (night) After Full Charge In 8 To 10 Hrs And Fixing The Same On Road Surface By Applying Approximately 100 Gm Epoxy Mixture And Placing The Cat Eye Without Applying Exessive Pressure And Additional Fixed With Zinc Plated Steel Nail Of Suitable Size As Per Manufacturers Instructions At The Centre Of Cat Eye Complete All As Specified And As Directed. Make Dark Eye / 3m/ Greenlite, Subtotal, Lump Sum Price Worked Out By The Tenderer For Area Drainage Work)\" As Listed In Schedule A Section -vi, Lump Sum Price Worked Out By The Tenderer For Sewage Disposal Work\" As Listed In Schedule A Section - Vii (part-i), Sch \'a\' Sec - Vii (part-ii), (sewage Disposal Work), Supply And Laying Dwcpe (sn8) Drain Pipes 150mm Inner Dia (160mm Od) As Per Is-16098 (part-ii), Laid In Trenches On And Including Bed 100mm Thhick Beding Comprising Of Well Compacted Clean Poorly Graded Gravel, Gravel/sand Mixture With Little Or No Fines To Required Slope, Including All Accessories/fittings/jointing Ring, Jointing And Testing Complete All As Specified And As Directed By Engineer-in-charge. Note : Excavation, Earth Work And Pedestal /anchorage If Required Shall Be Measured & Paid Separately Under Appropriate Item Of Boq/sch A., Supply And Laying Dwcpe (sn8) Drain Pipes 200mm Inner Dia (238mm Od) As Per Is-16098 (part-ii), Laid In Trenches On And Including Bed 100mm Thhick Beding Comprising Of Well Compacted Clean Poorly Graded Gravel, Gravel/sand Mixture With Little Or No Fines To Required Slope, Including All Accessories/fittings/jointing Ring, Jointing And Testing Complete All As Specified And As Directed By Engineer-in-charge. Note : Excavation, Earth Work And Pedestal /anchorage If Required Shall Be Measured & Paid Separately Under Appropriate Item Of Boq/sch A., Supply And Laying Dwcpe (sn8) Drain Pipes 300mm Inner Dia (380mm Od) As Per Is-16098 (part-ii), Laid In Trenches On And Including Bed 100mm Thhick Beding Comprising Of Well Compacted Clean Poorly Graded Gravel, Gravel/sand Mixture With Little Or No Fines To Required Slope, Including All Accessories/fittings/jointing Ring, Jointing And Testing Complete All As Specified And As Directed By Engineer-in-charge. Note : Excavation, Earth Work And Pedestal /anchorage If Required Shall Be Measured & Paid Separately Under Appropriate Item Of Boq/sch A., Subtotal, Lump Sum Price Worked Out By The Tenderer For Security Fencing, Compound Wall And Gate Works\" As Listed In Schedule A Section - Viii, Lump Sum Price Worked Out By The Tenderer For External Water Supply Works\" As Listed In Schedule A Section - Ix (part-i), Sch \'a\' Sec - Ix (part-ii), (external Water Supply Works), Material And Labour For Cutting Of Existing Ci/di Pipes Line 300mm Bore For Inserting And Including Tee Of Size 300x300x200mm For Taping In Trenches Including Run Lead Joint Complete All As Specified And As Directed. Note:- Necessary Earth Work, Ci Fitting/lead Joints Etc Reqd To Complete The Job Deemed To Be Included In The Quoted Rate., Supply And Fixing Cast Iron Sluice Valve 300 Mm Dia With Flanged Ends Class I Pn 1.6 (heavy Duty Isi Marked) Confirming To Is:14846-2000, Drilled Type, Steel Spindle, Ci Gate With Brass Ring, Iron Wheel Handle, Suitable For Di Pipe Line, Complete Including Jointing Material Such As Nuts, Bolts, Washers And Rubber Sheet Insertion 3.0mm Thick At Both Ends Etc Complete All As Specified And As Directed., Supplying, Laying, Jointing And Testing Ductile Iron Pipe (isi Marked) Class K-9, Bore 200mm, Confirming To Is : 8329-2k, Spigot & Socketed Ends Centrifugally Cast, With Cement Mortar Lining Inside And Metallic Zinc Coating With Finishing Layer Of Bituminous Paint On Outside The Pipe, Suitable For And Including Rubber Tyton Joints (push-on Joint) Complete All As Specified And As Directed. Note : (i) Earth Work, Di Specials/ Fittings Shall Be Measured And Paid Separetly. (ii) Test Certificate For Pipes From Manufacturer Shall Be Produced. No Payment Shall Be Entertained Without Test Certificate., Supplying, Laying, Jointing And Testing Ductile Iron Pipe (isi Marked) Class K-7, Bore 150mm, Confirming To Is : 8329-2k, Spigot & Socketed Ends Centrifugally Cast, With Cement Mortar Lining Inside And Metallic Zinc Coating With Finishing Layer Of Bituminous Paint On Outside The Pipe, Suitable For And Including Rubber Tyton Joints (push-on Joint) Complete All As Specified And As Directed. Note : (i) Earth Work, Di Specials/ Fittings Shall Be Measured And Paid Separetly. (ii) Test Certificate For Pipes From Manufacturer Shall Be Produced. No Payment Shall Be Entertained Without Test Certificate., Supplying, Laying, Jointing And Testing Ductile Iron Pipe (isi Marked) Class K-7, Bore 100mm, Confirming To Is : 8329-2k, Spigot & Socketed Ends Centrifugally Cast, With Cement Mortar Lining Inside And Metallic Zinc Coating With Finishing Layer Of Bituminous Paint On Outside The Pipe, Suitable For And Including Rubber Tyton Joints (push-on Joint) Complete All As Specified And As Directed. Note : (i) Earth Work, Di Specials/ Fittings Shall Be Measured And Paid Separetly. (ii) Test Certificate For Pipes From Manufacturer Shall Be Produced. No Payment Shall Be Entertained Without Test Certificate., Supply And Fixing Cast Iron Sluice Valve 200 Mm Dia With Flanged Ends Class I Pn 1.0 (heavy Duty Isi Marked) Confirming To Is:14846-2000, Drilled Type, Steel Spindle, Ci Gate With Brass Ring, Iron Wheel Handle, Suitable For Ci/di Pipe Line, Complete Including Jointing Material Such As Nuts, Bolts, Washers And Rubber Sheet Insertion 3.0mm Thick At Both Ends Etc Complete All As Specified And As Directed., Supply And Fixing Cast Iron Sluice Valve 150 Mm Dia With Flanged Ends Class I Pn 1.0 (heavy Duty Isi Marked) Confirming To Is:14846-2000, Drilled Type, Steel Spindle, Ci Gate With Brass Ring, Iron Wheel Handle, Suitable For Ci/di Pipe Line, Complete Including Jointing Material Such As Nuts, Bolts, Washers And Rubber Sheet Insertion 3.0mm Thick At Both Ends Etc Complete All As Specified And As Directed., Supply And Fixing Cast Iron Sluice Valve 100 Mm Dia With Flanged Ends Class I Pn 1.0 (heavy Duty Isi Marked) Confirming To Is:14846-2000, Drilled Type, Steel Spindle, Ci Gate With Brass Ring, Iron Wheel Handle, Suitable For Ci/di Pipe Line, Complete Including Jointing Material Such As Nuts, Bolts, Washers And Rubber Sheet Insertion 3.0mm Thick At Both Ends Etc Complete All As Specified And As Directed., Material And Labour For Construction Of Brick Masonary Valve Pit Chamber Size 105 X105 X105 Cm (internal Dimension) Using Sub Class \'b\' Bricks Complete Including Excavation & Earth Work, Returning Fillig And Disposal Of Surplus Soil To Distance Not Exceeding 50m And Deposited Where Directed, Pcc (1:3:6) Type C-2 Using 40 Mm Graded Stone Aggregate In Foundation, Coping On Top In Pcc (1:2:4) Type B-1 Using 20 Mm Graded Stone Aggregate, Brick Work In Cement Mortar (1:4), Inner Plaster 12 Mm Thick In Cm (1:3) Finished Even And Smooth And Pionting Flush Externally As The Work Proceeds In The Same Mortar, Ms Sheet Cover 3.15mm Thick Mounted On Angle Iron Frame Of Size 40 X 40 X 6mm With Handle And Locking Arrangement Duly Painted With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer And Embeded Portion Of Ms Work Duly Applying Black Bitumenous Paint Before Embeded Complete All As Specified And As Directed., Material And Labour For Construction Of Brick Masonary Valve Pit Chamber Size 90 X90 X90 Cm (internal Dimension) Using Sub Class \'b\' Bricks Complete Including Excavation & Earth Work, Returning Fillig And Disposal Of Surplus Soil To Distance Not Exceeding 50m And Deposited Where Directed, Pcc (1:3:6) Type C-2 Using 40 Mm Graded Stone Aggregate In Foundation, Coping On Top In Pcc (1:2:4) Type B-1 Using 20 Mm Graded Stone Aggregate, Brick Work In Cement Mortar (1:4), Inner Plaster 12 Mm Thick In Cm (1:3) Finished Even And Smooth And Pionting Flush Externally As The Work Proceeds In The Same Mortar, Ms Sheet Cover 3.15mm Thick Mounted On Angle Iron Frame Of Size 40 X 40 X 6mm With Handle And Locking Arrangement Duly Painted With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer And Embeded Portion Of Ms Work Duly Applying Black Bitumenous Paint Before Embeded Complete All As Specified And As Directed., Material And Labour For Construction Of Brick Masonary Valve Pit Chamber Size 45 X45 X45 Cm (internal Dimension) Using Sub Class \'b\' Bricks Complete Including Excavation & Earth Work, Returning Fillig And Disposal Of Surplus Soil To Distance Not Exceeding 50m And Deposited Where Directed, Pcc (1:3:6) Type C-2 Using 40 Mm Graded Stone Aggregate In Foundation, Coping On Top In Pcc (1:2:4) Type B-1 Using 20 Mm Graded Stone Aggregate, Brick Work In Cement Mortar (1:4), Inner Plaster 12 Mm Thick In Cm (1:3) Finished Even And Smooth And Pionting Flush Externally As The Work Proceeds In The Same Mortar, Ms Sheet Cover 3.15mm Thick Mounted On Angle Iron Frame Of Size 40 X 40 X 6mm With Handle And Locking Arrangement Duly Painted With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer And Embeded Portion Of Ms Work Duly Applying Black Bitumenous Paint Before Embeded Complete All As Specified And As Directed., Supply And Fixing Di Fitting Upto 200 Mm Bore Pipe Line For Reducing/bends (any Type Radius And Angle) Tapers Any Type, Straight, Bend, Increasing Decreasing Or Double Socket Extra Tee Pieces Single Branch Y \'junction\' Double Branch Cross Collers Cap Etc Complete All As Specified And As Directed. Note:- Make Of Di Fittings Shall Be Same Make As Di Pipe Or As Per Recommendation Of Di Pipe Manufacturer., Subtotal, Lump Sum Price Worked Out By The Tenderer For External Electrification, Aviation Light And Lightning Protection Works\" As Listed In Schedule A Section - X (part-i), Sch \'a\' Sec - X (part-ii), (external Electrification, Aviation Light And Lightning Protection Works), Supply, Installing, Commissioning & Testing Transformer Suitable For 400 Kva (level-3) Step Down Floor Mounted Outdoor Type 11/.433, 3 Phase, 50 Hz Ac, Is: 1180-2014 Isi Marked, Double Wound Core Type Copper Wound, Oil Immersed, Air Naturally Cooled With External Cooling Tubes, Transformer Delta Connection On Hv Side And Star Connected On Lv Side In Accordance With Vector Symbol Dyn-11 (vector Group 4) With Neutral Brought Out On Lv Side With For Earthing And Having Tapping On Hv Side For Constant Output So As To Alter/vary Secondary Voltage By (tapping Range + 5 % To - 10% In Equal Step Of 2.5 % ) Changed By Means Of Manually Operated \" Off Load\" Taps Changing Gear. The Voltage Regulation Shall Be As Per Is Including First Fill Of Transformer Oil As Per Is-335 And Including All Fittings/accessories. The Limit Of Temperature Rise After Continuous Full Load Run As Specified In Is-1180 (part-i) 2014 And Bee Certified Shall Be Suitably Adjusted To Suit The Maximum Ambient Temperature Of 55 Degree Centigrade As Prevalent Complete All As Specified And As Directed And Shall Be Comprised With The Following Fittings And Accessories :-, (i) Oil Conservator Tank With Fillings Holes And Cap Filter Type Drain Valve And Oil Level Gauge. (ii) Silica Gel Breather With Connecting Pipe, First Fill Of Dehydrating Agent. (iii) Explosion Relief Mounted On Tank With Double Diaphram And Equalizer Pipe Connected To Conservator Air Tank (pressure Release Valve) (iv) Air Release Valve Plug (v) One Cable Box On Lv Side (secondary) Consisting Of 04 Nos Porcelain Bushing With Nuts, Washers & Bushing Rods With 01 Cable Gland Suitable For Reception Of Taking Out Suitable Size Cable, Including Gland Joints (vi) Explosive Vent (vii) 01 No 100 Mm Dial Type Thermometer Vapour Pressure Type Having Range 0-120 Degree Centigrade With Max Temp Indicator And Resetting Device Incl Max Reading Pointer Washer Etc. (viii) Thermometer Pocket On Tank Cover (ix) 04 Nos Plain Solid Ci Datachable Rollers (x) Two Nos Earthing Terminals Marking Plate. (xi) Rating Plate And Terminal Marking Plate (xii) Extra Bushing For Neutral Outside The Cable Box Brought Out On Lv Side. (xiii) First Filling Of Oil Conforming To Is And Tested Upto 60 Kv Dielectric Strenght (xiv) Lifting Lugs (xv) Oil Drain Valve With Plug (xvi) One Cable Box On Hv Side (primary) Consisting Of 01 Cable Gland Suitable For Reception Of Taking In Ht Cable Including Gland Joints (xvii) Hand Hole Of Sufficient Size To Assess Interior Of Tank (xviii) Dehydrating Breather With First Filling Of Dehydrating Agent (xix) Two Earthing Terminal On Tank Body To Facilitate Fixing Of 32x6mm Gi Strip. ( ) Rating Plate With Terminal Marking Plate ( i) Inspection Cover., Note :- (a) Transformer Shall Be Pre-commisioned By Sei After Installation. (b) Cost Of All Necessary T&p And Measuring Devices Shall Be Provided By The Contractor Without Any Extra Cost. (c) Drawing Of Transformer Shall Be Approved By Ge Before Placing The Order. (d) Pre-dispatch Inspection At Factory Premises Shall Be Carried Out By Rep Of Accepting Officer. Contractor Shall Intimate The Planned Date Of Inspection Well In Advance. All Incidental Expenditure For Getting The Inspection/testing In The Factory Premises Shall Be Borne By The Contractor Including Transportation And Administration Arrangement For The Rep Of Accepting Officer Without Any Extra Cost To The Department. (e) Pcc Foundation, Plateform As Per Manufacturer Recommendation (one Metre High From Ground Level) Shall Be Provided By The Contractor Without Any Extra Cost. , Material And Labour For Earthing Complete With Galvanised Iron Earth Plate Electrode Of Size 600 X 600 X 6 Mm Buried Directly In Ground (earth Pit Not Less Than 2.25 Mtr Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 Metre Below Normal Ground Level, Connected To And Including Gi Earthing Wire Of Size 4 Mm Dia By Means Of Gi Bolts/nuts/washers And Protected By 15 Mm Bore Gi Light Grade Pipe Upto Test Point Or Upto Main Switch Board, Ht/lt Equipments, Fixing With 02 Nos Nuts And Bolts And Protection Pipe Fixed With And Including Flat Iron Clamps, Bolts, Nuts And Washers. Earth Plate Shall Be Surrounded By Alternate Packed Layer 15 Cm Thick Of Charcoal Or Coke And Common Salt All Around Bottom And Top. 20 Mm Bore Gi Medium Grade Pipe For Watering And Including Funnel, Wire Mesh, Pcc Chamber Pit Made With Pcc (1:3:6) Type C1 (using 20 Mm Graded Stone Aggregate) Including Necessary Form Work, Excavation And Earth Work In Any Type Of Soil, Returning Filling And Disposal Of Surplus Soil To A Distance Not Exceeding 50m, Pit Cover 40mm Thick Made With Rcc (1:2:4) Type B1 (using 20 Mm Graded Stone Aggregate) Including Tmt Reinforcement 8mm Dia @ 75mm C/c Both Way, Ms Handle 12mm Dia, Cover Rest On Ms Angle Iron Frame 40x40x6mm Embeded In Concrete Duly Painted With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer, Complete All As Specified & Shown In Electrical Plate No. 3 Of Ssr 2009 (part-i) Complete All As Specified And As Directed By Engineer-in-charge. Note:- (i) Pcc Chamber Shall Be Constructed At Least 1.5 Metre Away From The Earth Electrode And Pipe For Watering Shall Be Provided In Slanting Manner. (ii) Protection Pipe And Gi Earthing Wire Upto Test Point Or Upto Electric Equipment From Top Of Earth Plate Shall Be Included In The Unit Rate Of This Item. (iii) The Earth Testing Arrangement Should Be Done By The Contractor As Per Direction Of Engineer-in-charge. (iv) Qty 28 Nos For Sch \'a\' Sec - Ii (part-ii), (internal Electrification Work) And Qty 23 Nos For Sch \'a\' Sec - X (part-ii) (external Electrification Works), Material And Labour For Earthing Complete With Galvanised Iron Earth Plate Electrode Of Size 600 X 600 X 6 Mm Buried Directly In Ground (earth Pit Not Less Than 2.25 Mtr Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 Metre Below Normal Ground Level, Connected To And Including Gi Earthing Strip 32x6mm By Means Of Gi Bolts/nuts/washers And Protected By 40 Mm Bore Gi Light Grade Pipe Upto Test Point Or Upto Main Switch Board / Electric Equipment / Pole / Lightning Arrestor / Ht/lt Equipments / Godo Switch Etc, Fixing With 02 Nos Nuts And Bolts And Protection Pipe Fixed With And Including Flat Iron Clamps, Bolts, Nuts And Washers. Earth Plate Shall Be Surrounded By Alternate Packed Layer 15 Cm Thick Of Charcoal Or Coke And Common Salt All Around Bottom And Top. 20 Mm Bore Gi Medium Grade Pipe For Watering And Including Funnel, Wire Mesh, Pcc Chamber Pit Made With Pcc (1:3:6) Type C1 (using 20 Mm Graded Stone Aggregate) Including Necessary Form Work, Excavation And Earth Work In Any Type Of Soil, Returning Filling And Disposal Of Surplus Soil To A Distance Not Exceeding 50m, Pit Cover 40mm Thick Made With Rcc (1:2:4) Type B1 (using 20 Mm Graded Stone Aggregate) Including Tmt Reinforcement 8mm Dia @ 75mm C/c Both Way, Ms Handle 12mm Dia, Cover Rest On Ms Angle Iron Frame 40x40x6mm Embeded In Concrete Duly Painted With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer, Complete All As Specified & Shown In Electrical Plate No. 3 Of Ssr 2009 (part-i) Complete All As Specified And As Directed By Engineer-in-charge. Note:- (i) Pcc Chamber Shall Be Constructed At Least 1.5 Metre Away From The Earth Electrode And Pipe For Watering Shall Be Provided In Slanting Manner. (ii) Protection Pipe And Gi Earthing Strip Upto Electric Equipment From Top Of Earth Plate Shall Be Included In The Unit Rate Of This Item. (iii) The Earth Testing Arrangement Should Be Done By The Contractor As Per Direction Of Engineer-in-charge., Material And Labour For Brackets Made Out Of Gi Tubing Light Grade 32mm Dia, 1.2 Metre Long Bent To Shape At 120 Degree Angle At Half Metre From Bottom, Including Two Nos Clamps Made Out Of Ms Flat Iron Size 50x3 Mm For Fixing Of Bracket For Street Light On Steel Tubular /pcc Poles With Suitable Nuts And Bolts Including Painting To Ms Clamp And Nut Bolts With Two Coats Of Aluminium Paint Over A Coat Of Red Oxide Primer Complete All As Specified And As Directed., Supply And Fixing Of Hot Press Moulded Smc (sheet Moulding Compound) Junction Box Of Inside Dimention 250 Mm X 200mm X 105mm Including 4 Nos Aluminium Stud Terminal Of Suitable Size And One Nos Mcb Sp 2.5 Amps And Fixed On Pole With Clamps. Bolts And Nuts / Grouted In Coping Of Pole Complete With Two Coat Of Synethictic Enamel Paint Powder Coated As Provided By Manufacturermake Complete All As Specified And As Directed. Make: Sintex / Hensel, Supply And Fixing Energy Efficient Led Street Light Fitting Of 45w Pressure Die Cast Aluminium Housing/body, Heat Resistant Clear Toughened Glass, Better Optics For Uniform Distribution Street/roadway Luminaire, With Driver, Including Electric Connection With Suitable Size Of Wire From Junction Box To Street Light Fitting, Fixing The Light Fitting With And Including Bracket Made Out Of Gi Tubing Light Grade 32mm Dia, 1.2 Metre Long Bent To Shape At 120 Degree Angle At Half Metre From Bottom, Including Two Nos Clamps Made Out Of Ms Flat Iron Of Size 25x4 Mm With Suitable Nuts And Bolts For Fixing Of Bracket Including Painting To Ms Clamp And Nut Bolts With Two Coats Of Aluminium Paint Over A Coat Of Red Oxide Primer, Complete Fitting With All Accessories And Following Specifications, Complete All As Specified And Directed By Engineer-in-charge :- (a) Lumen System Efficacy Of Luminaire Should Be Minimum 110 Lumen Per Watt. (b) Input Voltage Range : 140 To 270 Volts (c) Temp Operating Range : Minus 10 C To Plus 50 C (d) Power Factor : Minimum 0.95 (e) Thd : Max10%. (f) Cri : Morethan 70 And Cct : 5700 K. (g) Ip Rating : Ip65. (h) Ik Rating : Minimum Ik07 (j) Built In Potted Led Driver Of The Make As Of The Luminaire. (k) Led Driver Should Be Complete With All Protections Viz Open/short Circuit Protection, Over Voltage Protection, All As Per Standard Design Of Manufacturer. (l) Surge Protection 10 Kv (inbuilt + Extended) (m) Lens - High Efficiency Wide Angle Lens. (n) Bis Approved Fixtures And Driver (o) Rated Life Time : 50000 Burning Hrs (average 10 To 12 Hrs Daily), Sand Cushioning, With Dry And Clean River Fine Sand (for Under Ground Cable) 8 Cm Before Laying Cable And 15 Cm After Laying And Punned To 18 Cm After Laying Of Cable Complete All As Specified And As Directed. Note:- (i) Punned Thickness Shall Be Considered For Payment Purpose (ii) Approved Local Tibba Dry Sand Free From Vegetations, Grass And Other Deleterious Substances Shall Be Used., Supply And Fixing Three Core Core (3x1.5sqmm) Flexible Flat/round Cable, Copper Conductor Multistranded, Pvc Insulated And Overall Pvc Sheathed, 1100 Volt, Drawn Through Lt Steel Tubular Poles For Connection To Street Light From Junction Box To Light Complete All As Specified And As Directed., Material And Labour For Cable Route Indicator Post Of Size 900x300x100mm Made Of Precast Cement Concrete (1:2:4) Type B-1, Using 20mm Graded Stone Aggregate, Rounded Tops As Directed And Embeded In Ground (450mm Below Ground And 450mm Above Ground Level) With Pcc (1:3:6) Type C-1, Using 20 Mm Graded Stone Aggregate Block Of Size 350x150x450mm, Including 5 Mm Thick Plastering All Round Of Exposed Surface Of Post Above Ground With Cm (1:4) And Finished Even And Smooth Without Using Extra Cement, Applying Two Coats Of Cement Base Paint On Plastered Surface Including Writing Letters (like Lt/ht Ug Cable, __ Feeder Etc.) With Synthetic Enamel Paint In Brown Colour In Suitable Size Including Earth Work And Form Work Complete All As Specified And As Directed., Supply, Installation, Commissioning And Testing Of Factory Made Cubical Type Lt Panel Board Of Suitable Size (cpri Approved) Out Door Type Outer Shell Made Out Of 3.15 Mm Thick Ms Sheet And Inner Shell Made Out Of 1.6 Mm Thick Ms Sheet And Ms Angle Section 50x50x6 Mm On Pcc 1:2:4 Type B-1 Platform 40 Cm Above The Ground Level And 45 Cm Below The Ground Level, Frame Factory Fabricated With Front And Back Openable Double Door System Lockable/openable By Keys Having Chromium Plated 19 Mm Dia Fancy Lock, Louvers And Air Vent Gasket For Natural Flow Of Air U Type Gasket Shall Be Used To Make The Outer Shell Completely Vermin Proof .suitable For 3 Phase 4 Wire 415 Volt, 50 Hz, Tested At Cpri For 35 Mva Rupturing Capacity At 415 Volts Factory Fabricated Having Modern Fabrication And Testing Process Which Includes Seven Tank Pretreatment Process Comprising Of Degreasing, Rinsing, De-rusting, Rinsing, Phosphatising, Rinsing And Passivation Followed By Powder Coat Painting Having Thickness Not Less Than 100 Microns Provided With Suitable Gasket To Make It Dust/vermin Proof And General Construction Confirming To Is:8623/93. The Four Pole Busbar Shall Be Insulated With Colour Code Heat Shrinkable Sleeve And Shall Be Mounted On Suitable Size \"f\" Class Insulator At An Interval Not More Than 250 Mm Through Out The Length Of The Four Pole Busbar. The Cubical Incomer Mccb As Well As Outgoing Shall Have Aluminium Four Pole Extension Links Of Current Carrying Capacity Not Less Than 1.5 Times The Rated Capacity Of Individual Feeder. The Extension Links Shall Not Be Less Than 300mm Long Supported On Suitable Size \"f\" Class Insulator Complete Including All Connections Incoming / Out Going All As Directed By Engineer-in-charge And Comprising Of Following Accessories :-, Four Pole, Aluminium Bus Bar 1200 Amps Insulated With Colour Coded Heat Shrinkable Sleeve And Shall Be Mounted On Suitable Size F Class Insulators, Acb 800 Amp, Fp, Thermal Megnatic Release (manual Fixed Type) 01 No (incoming), Mccb 350 Amp, Fp 50 Hz, 415 V, 36ka, Adjustable Type 02 Nos (out Going), Mccb 100 Amp, Fp 50 Hz, 415 V, 25ka, Adjustable Type 01 No (out Going), Mccb 20 Amp, Fp 50 Hz, 415 V, 25ka, Adjustable Type 04 Nos (out Going), Mccb 32 Amp, Fp 50 Hz, 415 V, 25ka, Adjustable Type 02 Nos (out Going), Mccb 40 Amp, Fp 50 Hz, 415 V, 25ka, Adjustable Type 02 Nos (out Going), Nature Switch For Automatic Switching Of Street Lights Three Phase Load Of 5 Kw Contactor Rating 20 Amps, Ip 54- 01 No. Make- Swadeep, Model- Swadeep-66-5kw3p, Multifunction Meter Digital Type Showing Volt, Amp, Frequency, Power Factor,kw, Kwh In Built Selector Switch With Suitable Ct Coils For Three Phase - 01 No, Led Indicated Lamp (r,y,b) One Set-01, Internal Power And Control Wiring With Suitable Size Pvc Insulated Multistranded Copper Wire., Note :- (i) All Type Of Spares Such As Glands, Lugs, Nuts, Bolts Etc, Necessary Excavation And Earthwork, Pcc Work And Making Good Disturbed Surfaces Shall Deemed To Be Included In The Quoted Unit Rate. (ii) Drawing Of Panel Shall Be Approved By Ge Before Fabrication., Supply, Installation, Commissioning And Testing Of Factory Made Cubical Type Lt Panel Board Of Suitable Size (cpri Approved) Out Door Type Outer Shell Made Out Of 3.15 Mm Thick Ms Sheet And Inner Shell Made Out Of 1.6 Mm Thick Ms Sheet And Ms Angle Section 50x50x6 Mm On Pcc 1:2:4 Type B-1 Platform 40 Cm Above The Ground Level And 45 Cm Below The Ground Level, Frame Factory Fabricated With Front And Back Openable Double Door System Lockable/openable By Keys Having Chromium Plated 19 Mm Dia Fancy Lock, Louvers And Air Vent Gasket For Natural Flow Of Air U Type Gasket Shall Be Used To Make The Outer Shell Completely Vermin Proof .suitable For 3 Phase 4 Wire 415 Volt, 50 Hz, Tested At Cpri For 35 Mva Rupturing Capacity At 415 Volts Factory Fabricated Having Modern Fabrication And Testing Process Which Includes Seven Tank Pretreatment Process Comprising Of Degreasing, Rinsing, De-rusting, Rinsing, Phosphatising, Rinsing And Passivation Followed By Powder Coat Painting Having Thickness Not Less Than 100 Microns Provided With Suitable Gasket To Make It Dust/vermin Proof And General Construction Confirming To Is:8623/93. The Four Pole Busbar Shall Be Insulated With Colour Code Heat Shrinkable Sleeve And Shall Be Mounted On Suitable Size \"f\" Class Insulator At An Interval Not More Than 250 Mm Through Out The Length Of The Four Pole Busbar. The Cubical Incomer Mccb As Well As Outgoing Shall Have Aluminium Four Pole Extension Links Of Current Carrying Capacity Not Less
Documents
Unlock the opportunities
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
Awarded Value
185610613.65 -
Selected Bidder
NAND LAL PURI AND SONS PRIVATE LIMITED
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane