Tender Description
Tender Description : Corrigendum : Repair And Maintenance To Lt Electric Supply And Connected Works At Afs Hakimpet Under Ge (af) Hakimpet - Note:-1. The Contractor Should Visit The Site Before Quoting The Tender To Know The Working Condition Of The Station.2. All Requisite Safely Measures Are To Be Adopted By Contractor On Site.3. The Contractor Shall Provide And Deploy Sufficient Electrician (as Approved By Ge / Engineer In Charge) Shall Report At 9:00 Hrs To Je E/m / Engineer In Charge To Collect The Complaints Job Card In Working Days And Complete The Same Completed Within 24 Hrs.4. The Complaints Shall Be Rectified Within 24 Hrs If The Complaints Is/are Not Attended / Not Completed Within 24 Hrs (except Repair/replacement Of Major Items) Recovery Will Be Done At Rs 500 Per Complaint Per Day.5. For Major Parts Like Replacement Of Mcb, Dbs, Mccbs Etc Should Be Rectified Within 3 Working Days, If The Contractor Not Rectify Within Time Then Recovery Will Be Done At Rs 1000 Per Complaint Per Day.6. After Completion Of Job Work Complaint, The Contractor Has To Produce Job Card Duly Signed By User & Je / Engineer In Charge.7. If Contractor Failed To Provide Their Electrician To Attend The Complains Then Recovery Will Be Done At Rs 1000 Per Day.8. The Contractor Should Procure Minimum 50% Of The Materials For All Items As Per Boq (other Than Paints) Mentioned In This Ca, Within 20 Days After Getting Sample Approval And Kept In Safe Custody So That No Delay In Work Due To Non-availability Of Materials Will Be Faced. Contractor Should Ensure During The Cause Of Work That He Has Minimum 25% Of Materials With Him Till The Completion Of Work. If Contractor Fail To Complete The Work Within Contract Due To Lack Of Fittings A Penalty Of 20% Shall Be Applicable On Quoted Rates By The Contractor.9. In Repair Works, Rate Quoted For Demolition /dismantling /taking Down Is Deemed To Be Inclusive Of Removing The Same From Site And Station.10. In Maintenance Works, The Contractor Should Maintain Separate Registers For Repair Works. Day To Day Complaints Should Be Noted In Those Registers With Si Nos Of Complaints, Location Qty Of Work, Status Of Complaints And Signature Of In Charge And Stamp Of The Office. Formal Will Be Given From Concern Age Office. The Contractor Should Obtain The Signature Of In Charge On The Same Day Of Work. These Register To Be Submitted To Je (e/m) On Every Weekend Without Fail.11. The Contracts Involving Working At Elevated Locations Of Buildings, Contractor Should Ensure Proper Safety Arrangements As Per Norms. Wearing Safety Belts And Helmets Are Mandatory. A Penalty Of Rs 1000 Per Day Will Be Recovered From Contractor If Safety Norms Are Not Followed.12. After Completion Of Work, No Stores/debris/ Loose Items Be Kept At Work Site Or Dumped Inside Station . Entire Area To Be Cleared And Waste Material Be Taken Outside From The Station ., Excavation In Trenches Not Exceeding 1.5m Wide And Not Exceeding 1.5m Depth And Getting In Hard/dense Soil For Laying Of Cables/ For Erection Of Poles/ For Stay Assembly Etc Complete All As Specified And Directed By Engineer-in-charge., Boaring/ Drilling (horizontally ) Of Holes Under Road, Pavement, Hard Standing By Trenchless Technology Using Ultra Sounding Technique And Necessary Machine Including Hdpe Pipe Of 80 Mm Dia Suitable For 0.4 Mpa Working Pressure. All As Specified And Directed By Engineer In Charge.., Supply And Spread Clean Dry River Sand In Trenches For Cushioning Of Cable Complete All As Specified And Directed By Engineer-in-charge. (note: Punned Down Thickness Only Shall Be Measured For The Purpose Of Payment), Supply And Fix Precast Concrete Cable Covers Class Lv Type 1, Flat Size 250 X 150 X 40 Mm M-20 Grade Concrete Laid Dry For Cable Protection Complete All As Specified And Directed., Returning, Filling In Trenches Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exceeding 25 Cm Complete All As Specified And Directed By Engineer-in-charge., Removing Surplus Excavated Material To A Distance Not Exc 50m And Depositing Where Directed At A Level Not Exceeding 1.5m Above The Starting Point Complete All As Specified And Directed By Engineer-in-charge., Material And Labour For 80mm Dia Bore Tubes, Light Grade Galvanised, With All Fitting And Fixed Complete To Walls/ Poles Or Laid In Trenches/ Floors For Cable Protection Complete All As Specified And Directed By Engineer-in-charge., All As Per Item No. 7 Here-in-before But Of Size 50mm Bore., All As Per Item No. 7 Here-in-before But Of Size 40mm Bore., Supply & Fixing In Replacement Of Lt Xlpe Insulated Strip Armoured Multi Stranded Aluminium Underground Cable Of 16 Sqmm 2 Core In Trenches Or Fixed On Pole/wall Or Drawn Through Pipes Including Suitable Size Of Lugs & Glands Etc Complete All As Specified And Directed By Engineer-in-charge., All As Per Item No. 10 Here-in-before But Of Size 10 Sqmm 4 Core, All As Per Item No. 10 Here-in-before But Of Size 25 Sqmm 4 Core, All As Per Item No. 10 Here-in-before But Of Size 35 Sqmm, 3.5 Core, All As Per Item No. 10 Here-in-before But Of Size 50 Sqmm, 3.5 Core, All As Per Item No. 10 Here-in-before But Of Size 70 Sqmm, 3.5 Core, All As Per Item No. 10 Here-in-before But Of Size 95 Sqmm, 3.5 Core, All As Per Item No. 10 Here-in-before But Of Size 120 Sqmm, 3.5 Core, All As Per Item No. 10 Here-in-before But Of Size 150 Sqmm, 3.5 Core, All As Per Item No. 10 Here-in-before But Of Size 240 Sqmm, 3.5 Core, All As Per Item No. 10 Here-in-before But Of Size 300 Sqmm, 3.5 Core, Demolition For Cement Concrete/road In Ground Floor And Paving N. Exc 15 Cm Thickness Below Or Above Ground Level Including Removal Of Rubbish To A Distance Exc 1.50 Km And N.exc 5.00 Km Etc Complete All As Specified, S&f (in Replacement) Octagonal Shaped Gi Hot Dipped Electric Pole, Polished Finished (7 Metre Long) Single Arm Bracket Complete With Rcc Base, Bolts, Nuts, Washers And Base Plaes All As Specified Including The Following:-(a) Excavation In Post Hole Not Exceeding For Pole Foundation & Getting Out In Soft Loose Soil, Returning, Filling In The Excavated Soil After Fixing The Pole In Foundation, Ramming Earth Around In Layers N.exc 25 Cm Thick And Disposal Of Surplus Soil To A Distance N.exc 50 Metres.(b) M&l For Providing Rcc Foundation As Per Manufacturers Design Upto Gl Including Nuts, Bolts, Washers And Base Plates Of Suitable Size And Length For Grouting In As Per Manufacturers Design.(d) Inbuilt Internal Junction Box Consists Of Incomer Of Mcb Tpn 32 Amp 10 Ka And Internal Wiring Complete(e) Attached Gi Pipe Bracket Made Out Of Galvanised Iron Tubing 40mm Bore (dia), Light Grade, 1.50 Metre Long Bent To Shape As Per Specified For Fixing Street Light Fitting Including Suitable Size Of Clamps., Dismantling And Taking Down Existing Serviceable/unserviceable/ De-shaped/worn Out Lt/ht Pcc Pole Of Any Shape, Size & Height Including Demolition Of Existing Pcc Foundation Complete All As Specified And Directed By Engr-in-charge., Supply And Connect Pvc Insulated, Pvc Sheathed Copper Conductor Cable Three Core Of Size 2.5 Sqmm Complete All As Specified And Directed By Engineer-in-charge., M&l For Earthing Complete With Galvanized Steel Earth Plate Electrode 600x600x6mm Thick Buried Directly In Ground Earth Pit Not Less Than 2.25mtr Deep Below Normal Ground Level With Top Edge Of The Plate Not Less Than 1.5 Mtr Below Ground Level Connected To Galvanized Iron Or Steel Earth Lead Strip 32x6 Mm Size Upto 7.5 Mtr Long In Single Length By Mean Of Nut/bolt And Washer Of Galvanized Iron Or Steel As Shown In Electrical Plate No 5 Of Ssr Part I Including Necessary Excavation In Hard/dense Soil And Earth Work Gi Pipe 20mm Dia Mediumj Grade For Watering And Gi 15mm Dia Light Grade Pipe For Protection Of Gi Earth Wire Etc, Pcc Chamber With Pcc Cover In Cement Concrete 1:2:4 Type B1(20mm Graded Aggregate), Funnel, Wire Mesh, Charcoal Dust, Salt Etc, Connected To Lt Panel Board As Indicated Including Testing Complete All As Specified And As Directed., Material And Labour For Cable Jointing Kit For 1100 Volts Grade Cable For Straight Through Joint (heat Shrink System) Complete With Jointing Material And Accessories Suitable For 3.5/4 Core Xlpe/pvc Insulated Armoured Aluminium Conductor Cable Of Size 240/300 Sqmm Complete All As Specified And Directed By Engineer-in-charge., All As Per Item No. 26 Here-in-before But Of Size 150 Sqmm To 185 Sqmm. , 3.5/4 Core, All As Per Item No. 26 Here-in-before But Of Size 3.5/4 Core, 70 Sqmm To 120 Sqmm., All As Per Item No. 26 Here-in-before But Of Size 3.5/4 Core, 25 Sqmm To 50 Sqmm., M&l Mccb 4 Pole, Current Rating 250 Amp, Microprocessor Based, Thermal Setting Adjustable 70%-100% Breaking Capacity 25ka At 415v,50hz. Including Both Side Spreader, All As Per Item No. 30 Here-in-before But Of Capacity 160 Amps, 36 Ka, All As Per Item No. 30 Here-in-before But Of Capacity 25-63 Amps, 16ka, All As Per Item No. 30 Here-in-before But Of Capacity 100 Amps, 16ka, All As Per Item No. 30 Here-in-before But Of Capacity 125 Amps, 16ka, M&l Mccb 3 Pole, Current Rating 400 Amp, Microprocessor Based, Thermal Setting Adjustable 70%-100% Breaking Capacity 36ka At 415v,50hz Including Both Side Spreader ., M&l Mccb 3 Pole, Current Rating 350 Amp, Microprocessor Based, Thermal Setting Adjustable 70%-100% Breaking Capacity 35ka At 415v,50hz Including Both Side Spreader ., Supply And Fix On Load Changeover Rotory Type Switch 100amps, 4 Pole , Suitable For Lt Panel Including Taking Down Existing Unserviceable Changeover Switch Complete All As Specified And Directed By Engineer-in-charge., Supply And Fix Off Load Changeover Rotory Type Switch 200amps, 4 Pole , Suitable For Lt Panel Including Taking Down Existing Unserviceable Changeover Switch Complete All As Specified And Directed By Engineer-in-charge., Material And Labour For Spray Painting With Two Coats Of Enamel Paint Surfaces Of Any Description Of Approved Colour Over One Coat Of Red Oxide Metal Primer After Scraping Thoroughly The Existing Corroded Metal Surface Of The Lt Panel At Installed Position All As Directed By Engineer-in-charge., M&l For Earth Continuity Gi Strip 32x6 Mm With Saddles And Fixing Screws Etc Fixed To Wall On Batten/porcelain Insulator Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Including Breazing At Each Necesasry Joints Etc., Dismantling And Taking Down Existing Serviceable/unserviceable/ De-shaped/worn Out Lt/ht Steel Pole / Itmb Pole Of Any Shape, Size & Height Including Demolition Of Existing Pcc Foundation Complete All As Specified And Directed By Engr-in-charge., Cutting/pruning Of Tree Branches Along /around Over Head Lt Line At Places Within A Radius Of 2 Mtr From Fasted Conductor And Removing From Site Complete All As Specified And Directed, Checking, Identifying The Defect /faulty Point Of Lt Ug Cable Of Any Size Using Cable Fault Locator Machine Or By Mannual Excavation And Taking Out Bricks From The Trench Upto Fault Point Along Cable Route And Re-laying The Same Using Old Bricks/sand Incl Returning Filling And Making Good Surface After Rectification Of Defect Complete All As Directed., Material And Labour For Acsr Conductor And Proper Stringing For Required Tension And Sag Including Binding With New Aluminium Binding Wire Of Suitable Size Complete All As Specified And Directed By Engineer-in-charge., Disconnecting Of Oh Line Of Acsr Conductor/gi Earthing Wire, Opening Of Binding Wires, Jumper Connections Any Size And Restringing, Tightening Of Conductor With Suitable Line Vice, Replacing All Worn Out Jumper Connection With Suitable Conductor, Re-tightening And Straightening All Cross Arms, Insulators, Clamps Etc Including Replacement Of All Wornout Nut Bolts And Washers Complete All As Specified And Directed ., Material And Labour In Replacement Of Shackle Type, Porcelain, Vitreous, White, Brown Or Green Insulator Including Galvanised Mild Steel Straps, Washers, Insulator Bolts, Washers And Nuts For Working Pressure 1100 Volts Of Size 75mm Height And 90mm Dia Complete All As Specified And Directed By Engineer-in-charge., Material And Labour In Replacement Of Pin Type, Porcelain, Vitreous, White, Brown Or Green Insulator Including One Galvanised Mild Steel Spindle, Two Galvanised Iron Washers And One Galvanised Iron Nut, 100mm Height, 65mm Dia For 1100 Volts Grade Complete All As Specified And Directed By Engineer-in-charge., Supply And Fix In Replacement Of Rigid Pvc Lt Line Spacers Spiral/bolted Type As Per Is:1445-1977 Suitable For 2 Wires Complete All As Specified And Directed By Engr-in-charge., All As Per Item No.48 Here-in-before But Suitable For 4 Wires., Supply And Fixing Of Rim Latch With Two Levers, Of Mild Steel Body, Stove Enamelled Finish, With Brass Knob Or Lever Handle And Fixed Of Size 75mm Complete All As Specified And Directed By Engr-in-charge., Material And Labour In Replacement Of Cross Arms, Bracings, Supports, Clamps And Back Plates Fabricated From Structural Steel Sections Including Nuts, Bolts, Washers, Welding, Bending Cold Or Hot, Drilling Holes For Bolts, In Any Shape Or Size Including Applying Two Coats Of Aluminium Paint Over A Coat Of Red Oxide Primer Complete All As Specified And Directed By Engineer-in-charge., Material And Labour In Replacement Of Stay Assembly With 16mm Dia Stay Rod, Pcc 1:3:6 And All Accessories As Shown In Electrical Plate No. 1 Complete All As Specified And Directed By Engineer-in-charge., M&l For Preparation Of Old Painted Surfaces Of Lt 8.5/ 9.0 M Height Steel Tubular/ Ismb Poles By Scrubing Sand Paper Alongwith All Pole Fittings Such As Cross Arms, Clamps, Nuts & Bolts Etc And Applying Paint As Follows:- (i) One Coat Of Aluminium Paint On All Exposed Surfaces Of Pole, Cross Arms, Clamps, Nuts & Bolts Etc, Leaving In 1m From Ground Level. (ii) One Coats Of Synthetic Enamel Paint Of Approved Colour Upto 1.0m Height From Gl Including Coping. (iii) Writing Pole Number In White Letters On Black Background With Synthetic Enamel Paint Complete All As Specified And Directed By Engineer-in-charge., M&l For Preparation Of Old Painted Surfaces Of Lt 8.5/ 9.0 M Height Pcc Poles By Scrubing Sand Paper Alongwith All Pole Fittings Such As Cross Arms, Clamps, Nuts & Bolts Etc And Applying Paint As Follows:- (i) One Coat Of Aluminium Paint On All Steel Sections Such As Cross Arms, Clamps, Nuts & Bolts Etc, Leaving In 1m From Ground Level. (ii) One Coat Of Synthetic Enamel Paint Of Approved Colour Upto 1.0m Height From Gl Including Coping. (iii) One Coat Of Cement Base Paint On Balance Portion Of Pcc Pole. (iv) Writing Pole Number In White Letters On Black Background With Synthetic Enamel Paint Complete All As Specified And Directed By Engineer-in-charge., Supplying Only Aluminium Short Barrel Lugs Of 25 Sqmm Cross Sectional Area Complete All As Specified And Directed By Engr-in-charge., Supplying Only Aluminium Short Barrel Lugs Of 35 Sqmm Cross Sectional Area Complete All As Specified And Directed By Engr-in-charge., Supplying Only Aluminium Short Barrel Lugs Of 50 Sqmm Cross Sectional Area Complete All As Specified And Directed By Engr-in-charge., Supplying Only Aluminium Short Barrel Lugs Of 70 Sqmm Cross Sectional Area Complete All As Specified And Directed By Engr-in-charge., Supplying Only Aluminium Short Barrel Lugs Of 95 Sqmm Cross Sectional Area Complete All As Specified And Directed By Engr-in-charge., Supplying Only Aluminium Short Barrel Lugs Of 120 Sqmm Cross Sectional Area Complete All As Specified And Directed By Engr-in-charge., Supplying Only Aluminium Short Barrel Lugs Of 150 Sqmm Cross Sectional Area Complete All As Specified And Directed By Engr-in-charge., Supplying Only Aluminium Short Barrel Lugs Of 185 Sqmm Cross Sectional Area Complete All As Specified And Directed By Engr-in-charge., Supplying Only Aluminium Short Barrel Lugs Of 240 Sqmm Cross Sectional Area Complete All As Specified And Directed By Engr-in-charge., Supplying Only Aluminium Short Barrel Lugs Of 300 Sqmm Cross Sectional Area Complete All As Specified And Directed By Engr-in-charge., Supplying Only Fr Pvc Electrical Insulation Tape Of 1.8 Cm Width And 25 Mtr Length Complete All As Specified And Directed By Engr-in-charge., Material And Labour For Welding Of Lt Panel Doors Of Thickness Of The Panel Not Exceeding 6 Mm Complete All As Specified And Directed By Engr-in-charge., Supply And Labour For Fixing Of Single Core Aluminium Conductor Cable Xlpe Insulated Pvc Sheathed Al Round Wire Armoured Of 35 Sqmm Use As Jumper Connection Complete All As Specified And Directed By Engr-in-charge., Dismantling Of Aac Or Acsr Conductor Complete All As Specified And Directed By Engr-in-charge., Supply, Installation, Testing And Commissioning Of Oudoor Type Cubicle Panel Board Of Size Not Less Than 1500x1000x450 Mm Suitable For 3 Phase 4 Wire, 50 Hz Supply System Cpri Approved Factory Fabricated Made Out Of 3 Mm Thick Crca Sheet For Outer Shell And 2 Mm Thick For Inner Shell With Front And Rear Openable Double Lief Doors With Locking Arrangement Complete With Powder Coat Painting And Suitable Packing Material For Ip- 43 Degree Of Protection And Confirming To Is:8623-1993 And Including 50mmx50mmx6mm Angle Iron Base Frame Of Suitable Size For Mounting The Panel Board At A Height Of 450mm From Gl And Grouted On Pcc Foundation Complete All As Specified And Directed By Engineer-in-charge. Old Mccb Retrived From Panel Will Be Deposited At Age E/m Store. The Size Of Panel Board Shall Be Suitable For Accommodating And Including Provision Of Following Switchgears Complete:-, (a) Aluminium Bus Bar Of Capacity 600 Amp With Heat Shrinkable Coloured Pvc Sleeve Insulation Mounted On Suitable Insulators For 3 Phases And Half Of The Capacity For Neutral - 01 Set (b) Mccb, 400 Amps, 4 Pole,36 Ka Microprocessor Based 01no.(incoming). (c) Mccb, 160 Amps, 4 Pole, 36 Ka Microprocessor Based - 02 Nos (outgoing) (d) Mccb 100 Amps, 4 Pole, 16 Ka Microprocessor Based - 02 Nos. (outgoing)(e) Digital Voltmeter 0-500 Volts Range With Selector Switch - 01 No. (f) Digital Ammeter 0-500 Amps Range With Selector Switch And Cts - 01set (g) Led Type Pilot Indicator Lamps For R,y,b Phases - 01 Set Of 3 (h) Hardware Of Panel Board Including Bolt, Nuts Gaskets Etc. (i) Errection, Testing & Commissioning Including Pcc Foundation Blocks Of 2x Pcc Block Of Size, 500mm X 300 Mm X 100 Mm For Grouting Of Panel As Directed By Engr In Charge - 01 Job Note:- Drawing Will Be Approved By The Accepting Officer Before Placing Demand To The Manufacture., All As Per Item No 69 Here In Before But Specifications Of The Panel Are As Follows :-, (a) Aluminium Bus Bar Of Capacity 600 Amp With Heat Shrinkable Coloured Pvc Sleeve Insulation Mounted On Suitable Insulators For 3 Phases And Half Of The Capacity For Neutral - 01 Set (b) Mccb, 400 Amps, 4 Pole,36 Ka Microprocessor Based-01no.(incoming). (c) Mccb, 250 Amps, 4 Pole, 36 Ka Microprocessor Based - 01 Nos (outgoing) (d) Mccb 63 Amps, 4 Pole, 16 Ka Microprocessor Based - 03 Nos. (outgoing) (e) Mccb 100 Amps, 4 Pole, 16 Ka Microprocessor Based - 01 Nos. (outgoing)(e) Digital Voltmeter 0-500 Volts Range With Selector Switch - 01 No. (f) Digital Ammeter 0-500 Amps Range With Selector Switch And Cts - 01set (g) Led Type Pilot Indicator Lamps For R,y,b Phases - 01 Set Of 3 (h) Hardware Of Panel Board Including Bolt, Nuts Gaskets Etc. (i) Errection, Testing & Commissioning Including Pcc Foundation Blocks Of 2x Pcc Block Of Size, 500mm X 300 Mm X 100 Mm For Grouting Of Panel As Directed By Engr In Charge - 01 Job Note:- Drawing Will Be Approved By The Accepting Officer Before Placing Demand To The Manufacture., All As Per Item No 69 Here In Before But Specifications Of The Panel Are As Follows :-, (a) Aluminium Bus Bar Of Capacity 400 Amp With Heat Shrinkable Coloured Pvc Sleeve Insulation Mounted On Suitable Insulators For 3 Phases And Half Of The Capacity For Neutral - 01 Set (b) Mccb, 350 Amps, 4 Pole,36 Ka Microprocessor Based.-01no.(incoming). (c) Mccb, 160 Amps, 4 Pole, 36 Ka Microprocessor Based - 01 Nos .(outgoing) (d) Mccb 63 Amps, 4 Pole, 16 Ka Microprocessor Based . - 03 Nos. (outgoing) (e) Mccb 100 Amps, 4 Pole, 16 Ka Microprocessor Based . - 01 Nos. (outgoing)(e) Digital Voltmeter 0-500 Volts Range With Selector Switch - 01 No. (f) Digital Ammeter 0-500 Amps Range With Selector Switch And Cts - 01set (g) Led Type Pilot Indicator Lamps For R,y,b Phases - 01 Set Of 3 (h) Hardware Of Panel Board Including Bolt, Nuts Gaskets Etc. (i) Errection, Testing & Commissioning Including Pcc Foundation Blocks Of 2x Pcc Block Of Size, 500mm X 300 Mm X 100 Mm For Grouting Of Panel As Directed By Engr In Charge - 01 Job Note:- Drawing Will Be Approved By The Accepting Officer Before Placing Demand To The Manufacture., Material And Labour For Inspecting And Servicing Of Oil Cooled/ Air Cooled Servo Controlled Voltage Stabilizer Of Following Capacities Installed At Various Locations Within Air Force Station Hakimpet By Cleaning The Complete Unit With Suitable Cleaning Agent And Checking The Serviceability State Of All The Switchgears/ Components Such As Variacs, Ecc Box, Stepper Motors, Rc Networks, Control Pcb, Carbon Brushes, Sensing Transformers, Synchronising Motor, Drive Gears Etc Complete And Replacing The Defective Spare Parts And Testing For Proper Fuctioning Complete All As Specified And Directed By Engineer-in-charge.note : Supply And Replacement Of Components / Spare Parts Will Be Measured And And Paid Separately Under Relevant Items Of Schedule A, However The The Cost Of Suitable Wires, Lugs, Nuts, Bolts And Washers Required For Control Wiring Shall Be Included In Quoted Rate., A) Up To 15 Kva, 240/415 V, 50 Hz Of Any Phases, B) 20 Kva To 30 Kva, 415 V, 50 Hz, Three Phase, C) 30 To 50 Kva, 415 V, 50 Hz, Three Phase, D) 60 To 75 Kva, 415 V, 50 Hz, Three Phase, E) 100 To 125 Kva, 415 V, 50 Hz, Three Phase, F) 160 To 300 Kva, 415 V, 50 Hz, Three Phase, Supply Only Ac Stepper Motor Of Capacity 3kg/cm Suitable For Servo Controlled Voltage Stabilizer Complete All As Specified And Directed By Engineer-in-charge. Make: Servomax/servocon/scan Power Stabilizer., Supply Only Ac Stepper Motor Of Capacity 10kg/cm Suitable For Servo Controlled Voltage Stabilizer Complete All As Specified And Directed By Engineer-in-charge. Make: Servomax/servocon/scan Power Stabilizer, Supply Only Motor Gear And Variac Shaft Gear Set Suitable For Servo Controlled Voltage Stabilizer Complete All As Specified And Dircted By Engineer-in-charge., Supply Only Rc Network 3kg/cm To 10 Kg/cm Suitable For Servo Controlled Voltage Stabilizer Complete All As Specified And Directed By Engineer-in-charge., Supply Only Sensing Transformer With Triac Board Complete All As Specified And Directed By Engineer-in-charge., Supply Only Control Pcb With Wiring Complete All As Specified And Directed By Engineer-in-charge., Supply Only Voltmeter 0 To 500 V Of Existing Type Suitable For Existing Servo Controlled Voltage Stabilizer Complete All As Specified And Directed By Engineer-in-charge., Supply Only Limit Switches Suitable For Existing Servo Controlled Voltage Stabilizer Complete All As Specified And Directed By Engineer-in-charge., Supply Only Pot Meters Suitable For Existing Servo Controlled Voltage Stabilizer Complete All As Specified And Directed By Engineer-in-charge., Supply Only Carbon Brushes Of Various Capacity Suitable For Existing Servo Controlled Voltage Stabilizer Complete All As Specified And Directed By Engineer-in-charge., Supply Only Variac Of Rating Upto 15a Suitable For Existing Servo Controlled Voltage Stabilizer Complete All As Specified And Directed By Engineer-in-charge., Supply Only Variac Of Rating Above 20a And Upto 35a Suitable For Existing Servo Controlled Voltage Stabilizer Complete All As Specified And Directed By Engineer-in-charge., Supply Only Ecc Box Suitable For Existing Servo Controlled Voltage Stabilizer Complete All As Specified And Directed By Engineer-in-charge., Material And Labour For Filtration/dehydration Of Transformer Oil Of Oil Cooled Servo Voltage Stabilizer Of Various Capacities Installed At Various Locations Within Air Force Station Hakimpet With Mobile Type Filtration Plant To Achieve Di-electric Strength Of 30 Kv For 1 Minute At 2.5mm Gap As Per Relevant Is Including Testing And Recording The Values Of Dielectric Strength Of Oil Before And After Filtration At Site With Transformer Oil Testing Machine Complete All As Directed By Engineer-in-charge., Supply And Topping Up Of Transformer Oil Into The Body Of Servo Controlled Voltage Stabilizer Having Di-electric Strength Of 40 Kv For 1 Minute At 2.5mm Gap As Per Relevant Is Complete All As Specified And Directed By Engineer-in-charge., Material And Labour For Inspecting And Servicing Of Apfc Panel Of Capacity From 55 Kvar To 75 Kvar Installed At Various Locations Within Air Force Station Hakimpet By Cleaning The Complete Panel With Suitable Cleaning Agent And Checking The Serviceability State Of All The Switchgears/ Components Such As Capacitors, Relays, Contactors, Mccbs, Control Mcbs, Fuse Cut Outs, Meters, Auto/manual Switches/ Push Buttons, Indications Lamps, Control Wiring Etc Complete And Replacing The Defective Spare Parts And Testing For Proper Fuctioning Complete All As Specified And Directed By Engineer-in-charge.note : Supply And Replacement Of Components / Spare Parts Will Be Measured And And Paid Separately Under Relevant Items Of Schedule A, However The The Cost Of Suitable Wires, Lugs, Nuts, Bolts And Washers Required For Panel Wiring Shall Be Included In Quoted Rate., Supply And Replace Capacitor Heavy Duty Contactor With Built In Auxiliary Contact Suitable For Capacitor Of Rating Upto 12.5 Kvar, 415 V, 3 Ph, 50 Hz Of Existing Type Complete All As Specified And Directed By Engineer-in-charge., Supply And Replace Capacitor Heavy Duty Contactor With Built In Auxiliary Contact Suitable For Capacitor Of Rating Above 12.5 Kvar And Upto 25 Kvar, 415 V, 3 Ph, 50 Hz Of Existing Type Complete All As Specified And Directed By Engineer-in-charge., Supply And Replace Multifunction Meter, Digital Type, 415 Volts With Built In Selector Switch Suitable For Ct Ratio - 200/5a Complete All As Specified And Directed By Engineer-in-charge., Supply And Replace 12 Stage Apfc Relay, 415 V, 3 Ph, 50 Hz Of Existing Model Complete All As Specified And Directed By Engineer-in-charge., Supply And Replace Heavy Duty Power Capacitors Of Rating 1 Kvar To 2 Kvar, 440 Volts, 3 Ph, 50 Hz Of Existing Type/ Model Complete All As Specified And Directed By Engineer-in-charge., Supply And Replace Heavy Duty Power Capacitors Of Rating 4 Kvar To 5 Kvar, 440 Volts, 3 Ph, 50 Hz Of Existing Type/ Model Complete All As Specified And Directed By Engineer-in-charge., Supply And Replace Heavy Duty Power Capacitors Of Rating 10 Kvar, 440 Volts, 3 Ph, 50 Hz Of Existing Type/ Model Complete All As Specified And Directed By Engineer-in-charge., Supply And Replace Heavy Duty Power Capacitors Of Rating 12.5 Kvar, 440 Volts, 3 Ph, 50 Hz Of Existing Type/ Model Complete All As Specified And Directed By Engineer-in-charge., Supply And Replace Heavy Duty Power Capacitors Of Rating 15 Kvar, 440 Volts, 3 Ph, 50 Hz Of Existing Type/ Model Complete All As Specified And Directed By Engineer-in-charge., Supply And Replace Current Transformer Of Ratio 200/5a, Cl-i, 10 Va For Measuring Purpose Complete All As Specified And Directed By Engineer-in-charge., Supply And Replace Led Type Pilot Light Indication Lamps For R, Y, B Phases Complete All As Specified And Directed By Engineer-in-charge., Supply And Replace Illuminated Push Buttons For On/off Purpose (red And Green) Of Existing Size Mounted On Front Door Of Panel Complete All As Specified And Directed By Engineer-in-charge., Supply And Replace On Delay Timer Of Existing Type Suitable For Apfc Panel Complete All As Specified And Directed By Engineer-in-charge., Supply And Replace Auto/ Manual Rotary Switch, 230v, 50 Hz Of Existing Type Complete All As Specified And Directed By Engineer-in-charge., Supply And Replace Axial Flow Ventilation Fan To Work On 230 V, 1 Ph, Ac Supply Of Existing Size/ Model Complete All As Specified And Directed By Engineer-in-charge., Supply And Replace Glass Fuse With Fuse Blow Indicator,6a, 230 V, 50 Hz Complete All As Specified And Directed By Engineer-in-charge., Supply And Replace Glass Fuse With Fuse Blow Indicator,200ma, 230 V, 50 Hz Complete All As Specified And Directed By Engineer-in-charge., Supply And Replace Auxiliary Contactor For Ac Control Std Coil Voltage 230 To 415 Volts, 50hz Of Any Type Complete All As Specified And Directed By Engineer-in-charge.,
Documents
Unlock the opportunities
Buy This Document-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
Awarded Value
1885555.55 -
Selected Bidder
Haasith constructions
Bidder List
| # | Name | Value | Position | Status |
|---|---|---|---|---|
| 1 | Please Subscribe | 2416606.00 | L4 | Rejected-AOC |
| 2 | Please Subscribe | 1946956.55 | L1 | Accepted-AOC |
| 3 | Please Subscribe | 2424414.00 | L5 | Rejected-AOC |
| 4 | Please Subscribe | 2386174.80 | L3 | Rejected-AOC |
| 5 | Please Subscribe | 2774464.00 | L7 | Rejected-AOC |
| 6 | Please Subscribe | 2669452.00 | L6 | Rejected-AOC |
| 7 | Please Subscribe | 2082185.00 | L2 | Rejected-AOC |