Tender Information

Indian Oil Corporation Limited
NTID 19431880
Tendering Authority Indian Oil Corporation Limited
Description supply of cardiology cathlab, consumable items - adult femoral introducer sheath with hemostatic valve in a kit containing puncture needle and 0.038 guide wire. 10-12 cm long. 5/6/7/8 f., adult femoral introducer sheath with hemostatic valve in a kit containing puncture needle and 0.038 guide wire. 203 cm long. 5/6/7/8 f., adult femoral introducer sheath with hemostatic valve and hydrophilic coating over the sheath, in a kit containing puncture needle and 0.038 guide wire. 10-12 cm long. 5/6/7/8 f., adult femoral introducer sheath with hemostatic valve and hydrophilic coating over the sheath, in a kit containing puncture needle and 0.038 guide wire. 203 cm long. 5/6/7/8 f., adult femoral introducer sheath with hemostatic valve in a kit containing puncture needle and 0.038 guide wire. 203 cm long. 9 to 12f., adult femoral introducer sheath with hemostatic valve in a kit containing puncture needle and 0.038 guide wire.10-12 cm long. 9 to 12f., pediatric femoral introducer sheath with hemostatic valve in a kit containing puncture needle and 0.021 j tip/straight tip guide wire. 4f, 5f, 6f., radial/brachial introducer sheath with hemostatic valve in a kit containing puncture needle and 0.021 mini guide wire (j tip/straight tip), 71 cm long sheath. 4f, 5f, 6f., radial artery cannulation kit comprising of arterial sheath, puncture needle 21 g, straight tip mini guide wire, sheath length of 11cm. 4f, 5f, 6f., radial artery cannulation kit comprising of hydrophilic coated arterial sheath, puncture needle 20 g, hydrophilic mini guide wire of 0.025. 5f, 6f., manifold two ports with knobs to turn right when open., manifold three ports with knobs to turn right when open., ptca kit containing - (i) three port manifold with knobs to turn right when open, (ii) one pressure line, (iii) saline connecting line,(iv) contrast connecting line, (v) one three way stop cock, (vi) short tube of 12 to 15 inches to connect to touhyborst, (vii) one y-connector hemostatic valve with spring type push and release mechanism,(viii) one inflation device with manometer upto 30 atmosphere (easy to operate with luminescent dial), (ix) one luer lock controlled syringe of 10 ml with finger grip, (x) insertion needle, (xi) torque device., three way stop cock with one male and two female ports and freely rotating adapter for coronary angiography., pressure line: 120-150 cm, 4-6 mm, compatible with manifold and three way ports., short connecting pressure line of 20-30 cm with male port in one side and female port in the other side., high pressure injector line to withstand pressure up to 1200psi, 75-100 cm length with luer lock male port and rotator., coronary angiography diagnostic catheters 100 cm or longer for femoral approach and various curves (wherever applicable) of 3.0, 3.5, 4.0, 5.0 as required from time to time. judkins left. 4f, 5f, 6f., coronary angiography diagnostic catheters 100 cm or longer for femoral approach and various curves (wherever applicable) of 3.0, 3.5, 4.0, 5.0 as required from time to time. judkins right. 4f, 5f, 6f., coronary angiography diagnostic catheters 100 cm or longer for femoral approach and various curves (wherever applicable). amplatz left (ali/alii/aliii).5f, 6f., coronary angiography diagnostic catheters 100 cm or longer for femoral approach and various curves (wherever applicable). amplatz right (ari/arii). 5f, 6f. coronary angiography diagnostic catheters 100 cm or longer for femoral approach and various curves (wherever applicable). lima catheter. 5f, 6f., coronary angiography diagnostic catheters 100 cm or longer for femoral approach and various curves (wherever applicable). rima catheter. 5f, 6f., coronary angiography diagnostic catheters 100 cm or longer for femoral approach and various curves (wherever applicable). multipurpose ai, aii/bi, bii. 4f, 5f, 6f., coronary angiography diagnostic catheters 100 cm or longer for femoral approach and various curves (wherever applicable) of 3.0, 3.5, 4.0 as required from time to time. ntr (non-torque right) type. 4f, 5f, 6f., coronary angiography diagnostic catheters, 125 cm long, for femoral approach and various curves (wherever applicable) of 3.0, 3.5, 4.0, 5.0 as required from time to time. judkins left. 4f, 5f, 6f., coronary angiography diagnostic catheters, 125 cm long, for femoral approach and various curves (wherever applicable) of 3.0, 3.5, 4.0, 5.0 as required from time to time. judkins right. 4f, 5f, 6f., balloon flotation angiography catheter (berman type) with side holes. 5f, 6f, 7f., balloon flotation angiography catheter (berman type) with side holes and end hole at the tip for wire access. 5f, 6f, 7f., mullin sheath with hemostatic valve and end marker. 6 to 14f, shuttle sheath, 40-60 cm long. 6f, 7f, 8f., pigtail catheter, 6-12 side holes, high flow rate for adult use. straight pigtail: 4, 5, 6 ,7 f., pigtail catheter, 6-12 side holes, high flow rate for adult use. marker pigtail, with radio opaque markers): 6, 7 f., pigtail catheter, 6-12 side holes, high flow rate for adult use. angled pigtail, with 145-155 degree angle): 5, 6 f., cobra catheter (c1, c2, c3): 4/5/6 f., head hunter catheter: 5/6 f., shepherd crook catheter (0.8 & 1): 5/6 f., simmons catheter, 5/6 f, (sim1, sim2), sidewinder catheter, 5/6 f., nih catheter, with end hole and side holes, 5/6 f., nih catheter, with side holes only, 5/6 f., bernstein curve angiography catheter, pigtail catheter for neonatal and pediatric use, short length of 70-80 cm: 4f, 5f., angiographic guide wire 0.035, ptfe coated, j tip, 150-160 cm length., angiographic guide wire 0.035, ptfe coated, j tip, extra length of 250-260 cm length., angiographic guide wire, ptfe coated, j tip, diameter 0.021. extra-length (250-260 cm)., angiographic guide wire, ptfe coated, j tip, diameter 0.025. extra-length (250-260 cm)., angiographic guide wire, ptfe coated, j tip, diameter 0.032. extra-length (250-260 cm)., angiographic guide wire, ptfe coated, j tip, diameter0.038, extra-length (250-260 cm)., radial diagnostic angiography catheter, single catheter for both left and right coronary angiography, tiger like curve, having a-traumatic tip with end and side hole, large lumen. 100-110 cm long, 5f. radial diagnostic angiography catheter, single catheter for both left and right coronary angiography, multipurpose a like curve with primary curve of 1305 degrees, having a-traumatic tip, large lumen. 100-110 cm long, 5f., radial diagnostic coronary angiography catheters, single catheter for cannulation of both the coronary arteries. with and without side hole, available in 4, 5, and 6 f, 100 cm long and available in different curve length of 3.5 to 4.5 cm., radial diagnostic coronary angiography multipack containing (i) 5 f diagnostic angiography catheter, single catheter for cannulation of both the coronary arteries, 100 cm long and curve length of 3.5 cm, (ii) 5 f radial sheath, 21 g puncture needle, compatible 0.018 guidewire, (iii) 180 cm long 0.035 angiographic guide wire with distal j tip., sterile, disposable catheterization drape for covering patients during angiography/catheterization procedures. size 100-120180-200 cm, with two 10-12 cm adhesive fenestrations at the site of femoral artery puncture (in the junction of upper 1/3rd and lower 2/3rd), having absorbent as well as laminated reinforcement., sterile, disposable catheterization drape for covering patients during radial angiography. size 120-140180-200 cm, with single 10-12 cm adhesive fenestration at the site of right radial artery puncture (in the right upper corner, one foot away from the right and the upper border of the drape), having absorbent as well as laminated reinforcement., contrast/saline injecting syringe for angiography (for multiple hand contrast injection in a single patient, non-breakable)., a) 2 cc, with luer lock, no finger grip., b) 5 cc, with luer lock, no finger grip., c) 10 cc, with luer lock, no finger grip., inflation device with manometer of 0 to 30 atmosphere and luminescent dial face. easy to operate with ergonomic design. high strength syringe to maintain high pressure setting without pressure loss and immediate pressure release., ptca insertion needle and torque device accepting 0.014 and 0.018 guide wires., y-connector for ptca: hemostatic valve with spring type push and release mechanism. it should have bleed back control valve and without formation of micro/macro air bubbles inside it during the procedure, having locking system to release., y-connector for ptca: hemostatic valve with spring type push and release mechanism. it should have bleed back control valve and without formation of micro/macro air bubbles inside it during the procedure, without locking system to release (only pull to release)., y-connector for ptca: hemostatic valve with spring type push and release mechanism. it should have bleed back control valve and without formation of micro/macro air bubbles inside it during the procedure, with short connecting tube of 10-12 cm attached to the side port., non spring screw type y-connector for ptca/pta., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., judkins left without side holes (curves 3, 3.5, 4, 5 cm), size 5f/6f/7f/8f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., judkins right without side holes (curves 3, 3.5, 4, 5 cm), size 5f/6f/7f/8f. ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., judkins right with side holes (curves 3, 3.5, 4, 5 cm), size 5f/6f/7f/8f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., ima guiding catheter, 5f/6f/7f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., multipurpose (ai, aii), 5f/6f/7f/8f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., multipurpose (bi, bii), 5f/6f/7f/8f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., amplatz left (curves al0.75, al1, al1.5, al2, al3), 5f/6f/7f/8f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., amplatz right (curves ar1, ar2), 5f/6f/7f/8f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., voda left, 5f/6f/7f/8f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., left coronary bypass guide catheter, 6f/7f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., right coronary bypass guide catheter, 6f/7f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., extra back-up (ebu) left, 5f/6f/7f/8f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., extra back-up (ebu) right, 5f/6f/7f/8f. ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., 3d right guiding catheter, 6f/7f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., hockey stick guiding catheter, 6f/7f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., shepherd crook right type guiding (curves 3.5, 4, 5), 6f/7f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., head hunter guiding catheter, 6f/7f., ptca guiding catheter, 110 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., judkins left without side holes (curves 3, 3.5, 4, 5 cm), size 5f/6f/7f/8f., ptca guiding catheter, 110 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., judkins right without side holes (curves 3, 3.5, 4, 5 cm), size 5f/6f/7f/8f., ptca guiding catheter, 110 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., judkins right with side holes (curves 3, 3.5, 4, 5 cm), size 5f/6f/7f/8f., ptca guiding catheter, 110 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., ima guiding catheter, 5f/6f/7f., ptca guiding catheter, 110 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., multipurpose (ai, aii), 5f/6f/7f/8f., ptca guiding catheter, 110 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., multipurpose (bi, bii), 5f/6f/7f/8f., ptca guiding catheter, 110 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., amplatz left (curves al0.75, al1, al1.5, al2, al3), 5f/6f/7f/8f. ptca guiding catheter, 110 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., amplatz right (curves ar1, ar2), 5f/6f/7f/8f., ptca guiding catheter, 110 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., voda left, 5f/6f/7f/8f., ptca guiding catheter, 110 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., left coronary bypass guide catheter, 6f/7f., ptca guiding catheter, 110 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., right coronary bypass guide catheter, 6f/7f., ptca guiding catheter, 110 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., extra back-up (ebu) left, 5f/6f/7f/8f., ptca guiding catheter, 110 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., extra back-up (ebu) right, 5f/6f/7f/8f., ptca guiding catheter, 110 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., 3d right guiding catheter, 6f/7f., ptca guiding catheter, 110 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f and 0.080 in 7f), stainless steel braided, inner layer coated with ptfe. it should have atraumatic soft tip with radio opaque marker band at the tip., hockey stick guiding catheter, 6f/7f., sterile puncture needle of 21 gauge, about 5 cm long, permitting insertion of 0.021 guide wire, with plastic jacket covering the needle part., sterile puncture needle of 18 gauge, 7 cm long, permitting insertion of 0.035/0.038 guide wire, with plastic jacket covering the needle part., amplatzer super stiff guide wire, long length of 260 cm to 300 cm of 0.035 size., cardiac bioptoms for endomyocardial biopsy. 4f, 5f, 6f., a) 100+5 cm for femoral approach, b) 45+5 cm for internal jugular approach., contra-lateral femoral sheath with dilator, 30-55 cm long. 6f, 7f, 8f, 9f, 10f., extra-long multipurpose diagnostic catheter, 125 cm long. 4f, 5f, 6f., extra-long multipurpose guide catheter, 125 cm long. 5f, 6f, 7f, 8f., pressure bag with manometer for iv infusion., dome kit with flushing system for philips fd-10c model., physiological pressure transducer and connector for philips fd-10c model. radiolucent ecg electrodes., defibrillator external pads (two) with connector compatible with existing bi-phasic defibrillator (model: mediana d500), digital cd 760 mb, archive grade for recording of angiography, angioplasty and echocardiography with name of hospital printed on it. they should have jacket made of tough glass or such material., dvd 4.7 gb, archive grade for recording of angiography, angioplasty and echocardiography with name of hospital printed on it. they should have jacket made of tough glass or such material with 10 mm width to write patient details., temporary pacemaker lead with balloon in the tip. 5f, 6f., asd/vsd/pda delivery kit containing i) delivery sheath with back bleed prevention hemostatic valve and side port, ii) dilator, iii) delivery cable, iv) loader. 6/7/8/9/10/11/12/13/14f., deflectable tip microcatheter with tapered tip of 1.7-1.91 f., 150 cc disposable plastic syringe for angiography injector of liebelflarshcism make., sterile pva particle for intravascular embolization, 300-1000 m diameter., spring coil ptca guide wire with no polymer and hydrophilic coating. it should have tapered tip (0.014- 0.010), and different tip loads, core-to-tip construction for good torque response used for ptca of cto., ptca guide wire with ptfe coating over shaft, polymer sleeve length of 20 cm, tip load of 0.8 gm., tip size of 0.014, tip radiopacity of 3 cm., ptca guide wire with ptfe coating over shaft, polymer sleeve length of 20 cm, tip load of 0.8 gm., tip size of 0.009, tip radiopacity of 16 cm., ptca extra-support guide wire with ptfe coating over shaft, tip load of 0.7 gm., tip size of 0.014, spring coil of 4 cm and tip radiopacity of 4 cm., ptca guide wire for cto with ptfe coating over shaft, tip size of 0.014, tip radiopacity of 11 cm and spring coil of 11 cm, length of 180-190 cm. various tip loads., ptca guide wire for cto with extra-support, tip load of 9 gm., tip size of 0.009, length 180-190 cm, with spring coil and tip radiopacity of 11 cm and spring coil and tip radiopacity of 20 cm., joint less spring coil 0.014 one piece core ptca guide wire with tip radiopacity 3 cm, length 180 cm, tip load of 0.5 gm. and 0.7 gm., dedicated guidewire for externalization in retrograde ptca with length >300 cm. steerable ptca guide wire with floppy tip, elastinite core, soft shaping ribbon tip and hydrophilic or hydrophobic coating., steerable ptca extra support guide wire with durasteel core material, core to tip design, floppy tip. with hydrophobic coating and with hydrophilic coating., steerable ptca 0.014 guide wire, distal nitinol core and rest stainless steel, double coil tip for shape retention, hydrophilic coating., ptca guide wire with polymer coated, hydrophilic, steel core and transitionless tip with various tip strength and tip load for torturous vessels., ptca extension wire/ doc wire. steerable pta guide wire with floppy tip, scitanium stainless steel alloy core, extra-support of 0.018 diameter, 300 cm long. tip non-hydrophilic or tip hydrophilic., steerable pta high support guide wire of 0.018, body ptfe/hydrophobic coated, distal hydrophilic coating, distal radiopacity of 2 cm, 300 cm long., ptca pre-dilatation, monorail/rapid exchange balloon (semi compliant). hypotube shaft design, low entry profile (0.017) and 5f guide catheter compatibility. radio-opaque markers at both ends., diameters (mm): 1.5, 2.0, 2.5, 3, 3.5, 4.0., length: 10 mm to 30 mm., (only manufacturers/firms having all mentioned diameters and lengths will be considered.), ptca pre-dilatation semi-compliant balloon, monorail/rapid exchange. ultra low entry profile with 5f guide catheter compatible, hydrophilic coating of the distal monorail part. radio-opaque marker for visibility., diameters (mm): 1.0, 1.2/1.25, 1.5, 2.0., length: 10 mm to 20 mm., (only manufacturers/firms having all mentioned diameters and lengths will be considered.), ptca pre-dilatation semi-compliant balloon, lowest tip entry profile of 0.016, crossing profile of 0.021, zero fold or minimum fold with low profile and marker for better visibility, stepwise transition stiffening for more pushability for difficult to cross lesions. radio-opaque marker (single) at the center of the balloon in small diameter balloons., diameter (mm): 1.2/1.25, 1.5, 2.0., length: minimum 6-8 mm to 12-15 mm., (only manufacturers/firms having all mentioned diameters and lengths will be considered.), ptca pre-dilatation semi-compliant over the wire balloon (otw) with short balloon taper, low entry profile (0.016)., diameter 1.2/1.25, 1.5,2.0, 2.5, 3.0 mm or more, length minimum 6-8 mm to 20mm or more., ptca pre-dilatation semi-compliant, monorail/rapid exchange balloon with lowest crossing profile for crossing difficult to cross cto lesions, having smallest balloon size of 0.80.1 mm diameter and length of 82 mm. other sizes available should be, diameter (mm): 1.2/1.25, 1.5., length (mm): 6/8, 10/12., (only manufacturers/firms having all mentioned diameters and lengths will be considered.), high pressure non-compliant balloon with 16 atm rbp, smooth, rounded distal tip and no edge over-dilatation at higher pressure; with least balloon overhang at the edges., available diameter(mm): 2.5, 3.0, 3.5, 4., length(mm): 10 to 30., (only manufacturers/firms having all mentioned diameters and lengths will be considered.), high pressure non-compliant balloon with 20 atm rbp, smooth, rounded distal tip and no edge over-dilatation at higher pressure., available diameter(mm): 2.25, 2.5, 2.75, 3.0, 3.25, 3.5, 3.75, 4, 4.5, 5.0., length(mm): minimum 6/8 mm to 20 mm., (only manufacturers/firms having all mentioned diameters and lengths will be considered.) ultra high pressure non-compliant balloon with 30 atm rbp for highly fibrotic or calcific vessels, no edge over-dilatation at higher pressure; with least balloon overhang at the edges., diameter(mm): 2.0, 2.5, 3.0, 3.5, 4., length(mm): minimum 6-8mm to 20 mm., (only manufacturers/firms having all mentioned diameters and lengths will be considered.), a) balloon only, b) balloon with dedicated inflation device to inflate balloon upto 45/50 atm., peripheral long balloon, semi compliant, various diameters of 4 to 8 mm. length: 20 to 100 mm. otw over 0.035 guide wire., peripheral long balloon, semi compliant, various diameters of 4mm to 8 mm. length: 20 to 100 mm. otw over 0.018 guide wire., peripheral balloon, semi compliant, various diameters of 4mm to 8mm. length: 20 to 40 mm. monorail, compatible over 0.014 guide wire., scoring balloon catheter. nitinol scoring element with two/three rectangular spiral sheets/wires on a semi-compliant balloon for coronary and peripheral applications., diameter (mm): 2.0, 2.5, 3.0, 3.5. length (mm): 10, 15., ptca cutting balloon with blades or such new cutting device at the surface of the balloon, blades/cutting devices arranged with hinges in every 5 mm of balloon for better trackability., various diameter and length., peripheral cutting balloon 4-6 mm diameter length up to 25/30 mm., femoral percutaneous closure device (thrombin/collagen mediated closure)., femoral percutaneous closure device (suture mediated closure)., radial closure device comprising of compression pad (pneumatically inflated with a syringe) with anatomic soft-wrist support pad., auto-perfusion catheter, 6f compatible with multiple side-holes and multiple radio opaque markers at the distal end., coronary wire braded micro-catheter for channel dilatation with platinum marker at distal tip for clear visibility. having 8 0.12 mm wire embedded in the shaft, long taper tip of 15 cm, tip 1.7-1.8 fr., mid shaft of 2.1-2.2 r. and proximal end of 3.3-3.4 fr., length 130-140 cm., complex channel or micro-channel crossing catheter with hydrophilic coating of distal segment, kink resistant tapered tip of 0.016, tungsten braiding, +10 elliptical stainless steel braids for better support., a) 130-140 cm for antegrade technique., b) 150-160 cm for retrograde technique., coronary microcatheter with distal diameter of 1.8 fr or less, proximal diameter 2.6f, ptfe coated inner layer, and distal hydrophilic coating at the outer layer, flexible tip with outer and inner taper with gold marker at distal tip for enhanced distal visibility to cross difficult lesions., a) 130-135 cm long, b) 150-160 cm long, dedicated coronary microcatheter for side branch access, coronary microcatheter with distal outer diameter of 2.7 f and proximal outer diameter of 2.9 f, with guidewire compatibility of 0.021 for microcoil embolization., snares: dual plane snare system with radio-opaque loop., a) small loop., b) large loop, amplatz goose neck snare kit intra-coronary foreign body retrieval forceps, radio opaque micro snare, small loop, 90 degree with kink resistant shaft., intra-vascular retriever device., permanent pacing lead extraction system., (a) whole device with locking device, mechanical dilator, and accessories, (b) lead locking device only, (c) mechanical rotating dilator/cutter only, balloon pre-mounted open cell cobalt chromium coronary stent. strut thickness 65 micron or less, entry profile 0.017 or less with lowest shaft profile. various diameters of 2.5 to 4 mm and length available upto 38 mm., balloon pre-mounted open cell stainless steel coronary stent. small strut thickness, with lowest shaft profile, 5f guide compatible. various diameters of 2.5 to 4 mm and length available upto 38 mm., intra-coronary thrombus extraction catheter, short tip monorail segment, big and round suction lumen, 0.014 wire compatibility. 6f, 7f., intra-coronary thrombus extraction catheter, tip monorail segment, big and round suction lumen with removable core steel wire for enhanced pushability, tip hydrophilic coating, 0.014 wire compatibility. 6f, 7f., mullins sheath 7-14 f, for adult ptmc/bmv, mullins sheath for pediatric procedure 5f/6f., trans-septal puncture needle, curved, for atrial septal puncture. for adult use., trans-septal puncture needle, straight, for atrial septal puncture. for adult use., trans-septal puncture needle, curved, for atrial septal puncture. for pediatric use., ptmc accessory- spring coil wire, extra stiff, metallic for ptmc/bmv., ptmc accessory -14 f dilator for ptmc/bmv, ptmc accessory stylet or j shaped lv entry wire during ptmc/bmv., amplatzer sizing plate for device closure., fixed tip deflectable e.p. catheters, all curve, compatible with the existing cordis ep system., bidirectional 7f e.p. catheter with tip electrode of 4 and 5 mm, all curves, compatible with the existing cordis ep system., decapolar coronary sinus catheter for jugular/ subclavian/femoral insertion, fixed and deflectable tip, 5 f & 7f with connector, compatible with the existing cordis ep system., parahisian diagnostic deflectable catheter, octapolar configuration catheter, compatible with the existing cordis ep system., 20-pole deflectable catheter for atrial isthmus mapping, compatible with the existing cordis ep system., quadripolar pacing lead 6f/7f with inter-electrode distance of 5 mm with connectors, compatible with the existing cordis ep system., quadripolar pacing lead 6f/7f with inter-electrode distance of 5 mm without connectors, compatible with the existing cordis ep system., 4 and 5 mm tip quadripolar tip deflectable rf ablation catheter 7f, all curves, and compatible with the existing cordis ep system., thermocool ablation catheter, compatible with the existing cordis ep system., connecting cables for eps catheter compatible with the existing cordis ep system. (connectors of the firm whose catheters are approved will be purchased). regular thermistor/thermocouple rf ablation catheter, compatible with the existing cordis ep system., radio frequency ablation catheter (4mm) compatible with ibi rf generator with connector(7f), different curves, push-pull technology., radio frequency ablation catheter (8mm) compatible with ibi rf generator with connector (7f), different curves, push-pull technology., impedance patches for electro-anatomical mapping for use with velocity mapping system., impedance patches compatible with ibi rf generator., balloon catheter for non-contact mapping of arrhythmias for use with velocity mapping system with connector., radiofrequency ablation saline cooled 4mm catheter compatible with ibi rf generator with connector (7f)., introducer sheath with hemostatic valve and locking hub (8f/8.5f,12 cm)., introducer sheath with 2 port hemostatic valve and locking hub (10 &12f,12 cm), introducer sheath with 3 port hemostatic valve and locking hub (12 &14f,12 cm), 7f, 4 mm bidirectional steerable ablation catheter with autolock mechanism (all curves) with connector compatible with meastro ablator, 7f, 8 mm bidirectional steerable ablation catheter with autolock mechanism (all curves) with connector compatible with meastro ablator, connector for radiofrequency ablation catheter compatible with meastro ablator and catheter of any make, connector for radiofrequency ablation catheter compatible with ibi rf ablator and catheter of any make, connector for radiofrequency ablation catheter compatible with stockert ablator and catheter of any make, radiofrequency ablation catheter(unidirectional def. curve, 6 / 7fr size with 4mm tip electrode, 2-5-2 mm inter-electrode, spacing/ 92-115cm insertion length, single thermistor/thermocouple sensor compatible with stockert ablator with connector, radiofrequency ablation catheter (polyurethane coating with bi-directional deflectable curve, 7fr size with 8mm tip electrode and 1-6-2 mm inter-electrode, spacing/115cm insertion length, single long thermocouple sensor compatible with stockert ablator with connector, irrigated tip ablation catheter, polyurethane coating with bi directional deflectable curve, 7fr size with 3.5mm tip electrode , 6 side-holes for open loop irrigation at the tip electrode , 2-5-2 mm inter-electrode, spacing/115cm insertion length, single thermocouple, sensor , compatible with stockert ablator with connector, regular navigation system catheters for mapping and ablation compatible with magnetic based 3d electro-anatomical system(7.5 f) with connector, irrigation tip navigation system catheters for mapping and ablation compatible with magnetic based 3d electro-anatomical system(7.5 f) with connector, pre-shape designed eps catheter to map crista terminals(7f), variable loop pulmonary vein mapping catheter compatible with magnetic based 3d electroanatomical mapping system(7f), high density mapping catheter compatible with magnetic based 3d electroanatomical mapping system(7f), external disposable non-sterile gel electrode compatible to magnetic-based 3d mapping system., indifferent patch electrode(reusable) for stockert with connecting cable, tubing for irrigated catheters compatible with cool flow pump fixed curve quadripolar electrophysiology catheter(all curve, 5-7f) with connector, fixed quadripolar catheter pre-curve shape for his position, deflectable quadripolar electrophysiology catheter(all curve, 5-7f) with connector, fixed curve decapolar catheter for coronary sinus mapping (all curve, 5-7f) with connector, deflectable decapolar catheter for coronary sinus mapping (all curve, 5-7f) with connector, duo decapolar electrophysiology catheter-20 poles with connector, intra cardiac echocardiaography imaging catheter(8-10f) compatible with philips cx 50 echo system., ffr wire of 0.014 diameter, compatible with the present available quantien machine (st. jude). with wireless connection to the console., disposable cover for image intensifier of philips flat panel machine of catheterization laboratory., disposable cover for foot paddles of philips flat panel machine of catheterization laboratory., disposable cover for console of philips flat panel machine of catheterization laboratory., vtk (vitek) catheter for carotid angiography, 125 cm long, 5f, uniselect catheter, 110-120 cm long, 5f, super-core guide wire, 0.035 size and extra-length of 280 cm or more., noodle wire, 0.035 diameter, 300 cm long., guide extension catheter, 5f/5.5 f/6f/7f, rapid exchange with 150 cm working length, soft tip with radiopaque marker., ecg connecting cable compatible with philips cath lab (fd-10c), mother and child catheter assembly for using smaller guide catheter inside large guide catheter., back-up meier steerable guidewires for catheterization and peripheral intervention, j tip, 0.035 diameter, 300 cm long., equalizer balloon, various sizes., wrap around double sided lead aprons for cath lab., two piece skirt & vest, double sided lead aprons for cath lab., wrap around, double sided, lead free, ultra-light good quality apron for cath lab., lead thyroid shield., pealway introducer sheath, 0.035 compatible, 6f/7f/8f/9f, steerable long sheath with hemostatic valve and deflectable tip, 6f to 14 f, length 50cm, 70 cm and 80 cm., shuttle sheath, with flexor tuohy borst side arm, 60 cm long, 6f, 7f, 8f, 9f., shuttle sheath, with flexor tuohy borst side arm, 80 cm long, 6f, 7f, 8f, 9f., long sheaths of various sizes with side arm (balkan/hausdorff type), for pediatric interventions. 4f, 5f, 6f. 30 to 50 cm long., long sheaths of various sizes with side arm (balkan/hausdorff type), for adult interventions. 6f, 7f, 8f. 60 to 80 cm long., radial hydrophilic sheath-less guide catheter, 7/7.5f size., iabp balloons with accessories for insertion, compatible with the existing datascope cs300 machine (with required connector). sizes available in 20, 24/25, 30/32, 34/36, 40 ml., refilling of helium gas cylinders from time to time for the existing iabp machine of datascope cs300., act tube compatible with the existing sonoclot coagulation analyzer machine of seinco inc. cartridges/cassettes for existing abg machine abl 80 flex (co-ox) of radiometer., re-entry balloon for cto with two exit port for wire entry in to the true lumen, percutaneous valvuloplasty balloon catheter for neonatal/pediatric use of different sizes with nominal rbp., percutaneous valvuloplasty balloon catheter for adult use, of different sizes available upto 30 mm and length upto 60 mm, with higher rbp (3-6 atm)., percutaneous valvuloplasty balloon catheter for adult use with dumbbell shaped narrowing of the central part for precise positioning across a valve, of different diameter of mid-size available upto 25/26 mm and length upto 40/50 mm, with higher rbp (3-5 atm)., percutaneous valvuloplasty bib (balloon-in-balloon) balloon catheter of different length and diameter., embolization coils of 0.014 diameter, different lengths, embolization coils of 0.018 diameter, different lengths, embolization coils of 0.021 diameter, different lengths, embolization coils of 0.035 diameter, different lengths, embolization coils of 0.038 diameter, different lengths, embolization coils of 0.052 diameter for pda closure, different lengths, park blade septostomy catheter, radifocus guide wire (terumo), j tip, with hydrophilic polymer coating, 0.035 diameter, 150-160 cm long, radifocus guide wire (terumo), j tip, with hydrophilic polymer coating, 0.035 diameter, 250-260 cm long, radifocus guide wire (terumo), j tip, with hydrophilic polymer coating, 0.032 diameter, 150-160 cm long, radifocus guide wire (terumo), j tip, with hydrophilic polymer coating, 0.032 diameter, 250-260 cm long, radifocus guide wire (terumo), j tip, with hydrophilic polymer coating, 0.021 diameter, 150-160 cm long, radifocus guide wire (terumo), j tip, with hydrophilic polymer coating, 0.021 diameter, 250-260 cm long, radifocus guide wire (terumo), straight tip, with hydrophilic polymer coating, 0.035 diameter, 150-160 cm long, radifocus guide wire (terumo), straight tip, with hydrophilic polymer coating, 0.035 diameter, 250-260 cm long, radifocus guide wire (terumo), straight tip, with hydrophilic polymer coating, 0.032 diameter, 150-160 cm long, radifocus guide wire (terumo), straight tip, with hydrophilic polymer coating, 0.032 diameter, 250-260 cm long, radifocus guide wire (terumo), straight tip, with hydrophilic polymer coating, 0.021 diameter, 150-160 cm long, radifocus guide wire (terumo), straight tip, with hydrophilic polymer coating, 0.021 diameter, 250-260 cm long, bidirectional, steerable soft-tip design, guiding sheath with small and large curve and variable reach, auto lock (between 8-10f), total length 90 cm., variable loop pulmonary vein mapping catheter compatible with magnetic based 3d electroanatomical mapping system(7f), intracardiac echocardiography for electrophysiology, four way steering to 160 degree, french size: 10 f & 8 f, length: 90 cms, compatible with carto system., eps connecting cable compatible with ibi ablator and j & j radiofrequency ablation catheter bi-directional steerable introducer sheath assorted sizes, contact force sensing catheter with force direction vector, bi directional movement, shaft visualization compatible with carto 3 mapping and rf ablation, life band (zoll) for automatic cpr machine compatible with auto pulse cpr machine., thermal recording paper, a4 size, (210 mm297 mm) cued-z fold, full grid for existing norav tmt machine. the que sensor should be as per the position required in the thermal sensors., ptfe coated guidewire for radial angiography, 0.035 diameter with distal, tip of 1.5 mm (small)., torque device for large wires (0.018 to 0.038), radial coronary angioplasty guiding catheters, single catheter for cannulation of both the coronary arteries. available in 5, and 6 f, 100 cm long and available in different curve length of 3.5 to 4 cm and with the option of having side holes., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f), stainless steel braided. it should have atraumatic soft tip with radio opaque marker band at the tip., judkins left with side holes (curves 3, 3.5, 4, 5 cm), size 5f/6f/7f/8f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f), stainless steel braided. it should have atraumatic soft tip with radio opaque marker band at the tip., judkins left with short tip (distance between the tip and primary curve) (curves 3.5, 4, 4.5 cm), size 5f/6f/7f/8f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f), stainless steel braided. it should have atraumatic soft tip with radio opaque marker band at the tip., judkins right with short tip (distance between the tip and primary curve) (curves 3.5, 4, 4.5 cm), size 5f/6f/7f/8f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f), stainless steel braided. it should have atraumatic soft tip with radio opaque marker band at the tip., judkins right with side holes and short tip (distance between the tip and primary curve) (curves 3.5, 4, 4.5 cm), size 5f/6f/7f/8f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f), stainless steel braided. it should have atraumatic soft tip with radio opaque marker band at the tip., multipurpose (ai) with side holes, 5f/6f/7f/8f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f), stainless steel braided. it should have atraumatic soft tip with radio opaque marker band at the tip., multipurpose (bi) with side holes, 5f/6f/7f/8f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f), stainless steel braided. it should have atraumatic soft tip with radio opaque marker band at the tip., amplatz left with short tip (curves al1, al1.5, al2, al3), 5f/6f/7f/8f. ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f), stainless steel braided. it should have atraumatic soft tip with radio opaque marker band at the tip., amplatz left with short tip and side holes (curves al1, al1.5, al2, al3), 5f/6f/7f/8f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f), stainless steel braided. it should have atraumatic soft tip with radio opaque marker band at the tip., amplatz right with side holes (curves ar1, ar1.2 ar2), 5f/6f/7f/8f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f), stainless steel braided. it should have atraumatic soft tip with radio opaque marker band at the tip., left extra support with side holes (curves 3, 3.5,4 4.5), 5f/6f/7f/8f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f), stainless steel braided. it should have atraumatic soft tip with radio opaque marker band at the tip., right extra support with side holes (curves 3.5,4 4.5, 5), 5f/6f/7f/8f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f), stainless steel braided. it should have atraumatic soft tip with radio opaque marker band at the tip., modified extra back-up, 5f/6f/7f/8f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f), stainless steel braided. it should have atraumatic soft tip with radio opaque marker band at the tip., modified extra back-up with side holes, 5f/6f/7f/8f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f), stainless steel braided. it should have atraumatic soft tip with radio opaque marker band at the tip.castillo curve 1, 2, 3. 6f/7f., ptca guiding catheter, 100 cm long:, it should be large lumen (minimum of 0.070 inner lumen in 6f), stainless steel braided. it should have atraumatic soft tip with radio opaque marker band at the tip., castillo curve 1, 2, 3 with side holes. 6f/7f., microcoil (0.018 diameter) delivery system, a) coil delivery micro catheter, b) coil pusher, pressure injector syringe compatible with medrad mark-7 arterioninjector., reusable pressure transducer plate compatible with mennen hemodynamic cath monitor., disposable act tubes compatible with existing machines (safdarjang hospital)., h2o2 and silver based solution for sterilization compatible with micro mist aerosol generator for sterilization of cath lab (1 bottle=10 l)., iabp balloon of different sizes with accessories for insertion, compatible with the existing datascope cs100 machine., refilling of helium gas cylinders for the existing iabp machine of datascope cs100.single lumen balloon flotation wedge pressure catheter (swan ganz type) with end hole. 4f, 5f, 6f, 7f., sterile, disposable catheterization drape for covering patients during intervention procedures. size 100-120300-320 cm, with two 10-12 cm adhesive fenestrations at the site of femoral artery puncture in both sides (in the junction of upper 1/3rd and lower 2/3rd), having absorbent as well as laminated reinforcement., rdc guide, 7f, 8f, straight guide 6f, 7f, 8f., radial guide catheter, ikari left curve. 3.5, 4, 4.5, 5 size, 5f/6f for radial angioplasty., radial guide catheter, ikari right curve. 1.0/1.5/2.0/2.5 size, 5f/6f for radial angioplasty., radial guide catheter, tiger type curve. 5f/6f size for radial angioplasty., goodale-lubin catheter, 6f., cournand catheter, 6f., picard catheter, 5f., fogarty catheter for atrial septostomy, 5f- 6f., atrial septostomy catheter, dual lumen shaft, radio opaque catheter body, marker in the balloon for balloon positioning, 30-450 angulated tip. over the wire., nucleus dilatation balloon with three markers, initial expansion of ends and later expansion of central part., multi track angiography catheter for angiography while catheter is over the wire by short monorail part at distal tip, size 5-7 f., percutaneous transluminal dilation balloon with markers for coarctation of aorta with high rbp., all sizes and various lengths., ultra high pressure valvuloplasty balloon dilation catheter with multiple markers., nbih woven bipolar temporary pacing electrode. 5f/6f/7f., bipolar temporary pacing lead, with central removable stillate for maintaining support and tip-curve. 5f/6f/7f., bipolar temporary pacing electrode for pediatric use. 4f/5f., radial diagnostic coronary angiography catheters, single catheter for cannulation of both the right and left coronary arteries, trapease like, ultracurve like or similar shapes, with and without side hole. 5f, and 6f, 100-110 cm long., high pressure non-compliant balloon with 22 atm rbp, smooth, rounded distal tip and no edge over-dilatation at higher pressure., available diameter(mm): 2.25, 2.5, 2.75, 3.0, 3.5, 4, 4.5, 5.0., length(mm): minimum 8/10 mm to 20 mm., (only manufacturers/firms having all mentioned diameters and lengths will be considered.), radial puncture site closure device comprising of compression pad (non-pneumatic compression technology) with anatomic soft-wrist support pad., radial guide catheter, mress, rrad, mradial, lara like curve. 3.0, 3.5, 4 size, 5f/6f for radial angioplasty., radial guide catheter, mac curve. 3.0, 3.5, 4 size, 5f/6f for radial angioplasty., guide extension catheter, 6f/7f/8f, rapid exchange, 145-150 cm working length with short hypotube transition for reducing stent interection/deformation and having dedicated catheter for using in transradial pci, soft tip with radiopaque marker at both end.
Estimated Cost 0.00
EMD
Doc Cost 0.00
Last Date for Submission 2019-07-20
Closing Date 2019-07-20
Location Indian Oil Corporation Limited India, West Bengal, Haldia
Tender Document Download Document
Inquiry