Special Repair To Certain E/m Infrastructure, Panels And Cables Of Dg Set/ac Plant And Other Associated Works At Af Stn Chandigarh
Documents
Unlock the opportunities
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
Refer Documents -
Document Cost
1000.00 -
Estimated Cost
Refer Documents
BOQ Items Total Items : 38 | Total Qty : 25676
# | Item | Quantity | Units |
---|---|---|---|
1 | Supply, installation in replacement, commissioning and testing of LT panel, indoor, cubical compartment type, of suitable size , CPRI approved, suitable for 1100 volts grade, 3 phase, 4 wire supply, made out of 2.0 mm thick CRCA sheet, duly powder coated with 7 tank process powder coating, both side openable, with locking arrangement, mounted on MS stand of suitable size made out of MS Angle iron of size 75x75x6 mm, frame fixed in PCC block 1:2:4 of suitable size , 04 Nos legs made from 50x50x6 mm angle iron and shall be 600 mm above ground level and 300 mm below ground, dust and vermin proof, making necessary cable connection with cable thimble, glands, including Aluminium TPN bus bar of capacity 300 Amp minimum size 32 x10 mm thick and minimum length not less then 900 mm each duly PVC/epoxy coated, mounted on PVC/epoxy insulators etc complete=1 Set and all MCCB's connection shall be with aluminum bus strip of suitable rating from main bus bar, MCCB's mounting arrangement shall be adjustable type, comprising of following complete all as specified :- (A) Incoming :- (a) MCCB 4 pole, 125 Amp 415 Volts, 50 Hz 25 KA with adjustable thermal and magnetic setting and with Ics = 75 % of Icu complete -01 No. (b) Change over switch on load type four pole front operated 415 volt 63 Amp - 01 No (c) Digital Voltmeter -0-500 Volts 96 x 96 mm flush mounting type with selector switch -01 No (d) Digital Amps meter 96 x 96 mm flush mounting type 0 - 150 amps with CT s 150/5 A and selector switch= 01 Set. (e) RYB Indication lamps-03 Nos and internal wiring with single core PVC insulated copper conductor cable of suitable size with control MCB SP in each circuit . (B) Out going:- (f) MCCB 4 pole,100 Amp 415 Volts, 50 Hz breaking capacity not less than 16 KA triple pole with adjustable thermal and magnetic setting -02 Nos. ((1W+1 (Spare )) and MCB TP 20 amps capacity 'C' series - 01 No (g) FASDS suitable for 30HP Monoblock pump electric driven pump set, 3 Phase , AC 415 volt ,50 HZ with Std protection ie single phase, over volt /under volt etc complete-01 No (h) DOL starter suitable for 7.5 HP Monoblock pump electric driven pump set ,3 Phase , AC 415 volt ,50 HZ with Std protection ie single phase, over volt /under volt etc complete-01 No (j) Digital Amp meter 0-100 Amp 96 x 96 mm flush mounting type with selector switch and 100/5A CTs -02 Nos {k} Earthing terminal - 02 Nos and danger notice plate dully rivetted/pasted on front side of panel board - 01 No | 1 | Each |
2 | Supply, installation in replacement, testing and commissioning of LT panel board (CPRI Approved) of suitable size factory made, compartment type, dust, water and vermin proof (IP-65 protetion) duly powder coated with 7 tank process powder coating , outdoor type with double door on front and rear side inclusive of locking arrangement, suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted fabricated out 3.15 mm CRCA Sheet on 50mm X 50mm X 6mm angle iron frame, 120 cm long legs 04 Nos made from 50x50x6 mm angle ironfor grouting in floor with PCC 1:2:4 foundation of suitable size with provision of all incoming/outgoing cable entries along with suitable size of double compression type cable gland for incomming & out going cable all as specified and comprising the following:- (for Base Ops ) a) LT bus bar aluminum TPN 600 Amps, 4 strips, duly sleeved with relevant colored insulation heavy duly mounted on epoxy insulators =1 Set Incomer : a) LT bus bar aluminum TPN 600 Amps, 4 strips, duly sleeved with relevant colored insulation heavy duly mounted on epoxy insulators =1 Set Incomer : (b) MCCB AC, 4 pole, 400 Amps,36 KA, 50 Hz, 415 Volts with adjustable thermal & magnetic seting and Ics = 100 % of Icu - 01 No Outgoing : (c ) MCCB AC, 4 pole, 160 Amps,25 KA, 50 Hz, 415 Volts with adjustable thermal & magnetic seting and Ics = 75 % of Icu= 03 No (2W +1 Spare) (d) MCCB AC, 4 pole, 100 Amps, 16 KA, 50 Hz, 415 Volts with adjustable thermal & magnetic seting = 01 No. (e) Change over switch 200 Amps four pole on load type 415 V - 01 No (f) Digital Amps meter 96 x 96 mm flush mounting type with CT s 400/5 A and selector switch= 01 Set. (g) Digital Voltmeter 0-500 volts 96 x 96 mm flush mounting type with selector switch =1Set. (h) Phase indicator lamps RYB =01 Set (j) Internal connections with colour code copper cable multistranded of suitable size copper thimbles etc as per manufacturers design and specfification incl SP MCB for protection in each circuit. (k) Danger notice plate 440 V with conventional skull and bones in red signal colour - 01 No and earthing terminals - 02 Nos | 1 | Each |
3 | Supply, installation in replacement, testing and commissioning of LT panel board (CPRI Approved) of suitable size factory made, compartment type, dust, water and vermin proof (IP-65 protection) duly powder coated with 7 tank process powder coating , outdoor type, suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted, fabricated out 3.15 mm thick CRCA Sheet, on 50mm X 50mm X 6mm angle iron frame, 120 cm long angle iron legs 04 Nos for grouting in floor with cement concrete PCC foundation of suitable size in 1:2:4 and front & rear double door type inclusive of locking arrangement with provision of all incoming/outgoing cable entries along with suitable size of double compression type cable gland for incomming & out going cable, complete all as specified and comprising the following:- (a) LT bus bar aluminum TPN 250 Amps, 4 strips, duly sleeved with relevant coloured insulation heavy duty mounted on epoxy insulators =1 Set Incomer : (b) MCCB AC, 4 pole, 160 Amps, 25 KA, 50 Hz, 415 Volts with adjustable thermal & magnetic seting and Ics = 75 % of Icu = 01 No. Outgoing : (c ) MCCB AC, 4 pole, 100 Amps, 16 KA, 50 Hz, 415 Volts with adjustable thermal & magnetic seting = 01 No (d) MCCB AC, 4 pole, 63 Amps, 16 KA, 50 Hz, 415 Volts with adjustable thermal & magnetic seting = 02 No (1W + 1 spare) (e) MCB, AC, SPN 20 Amps, 10 KA, 50 Hz, 240 Volts = 01 No (f) Digital Amps meter 96 x 96 mm flush mounting type with CT s 200/5 A and selector switch= 01 Set. (g) Digital Voltmeter 0-500 volts 96 x 96 mm flush mounting type with selector switch =1Set. (h) Phase indicator lamps RYB = 01 Set (j) Internal connections with colour code copper cable multistranded of suitable size copper thimbles etc as per manufacturer's design and specfifications (k) Danger notice plate 440 V with conventional skull and bones in red signal colour - 01 No and earthing terminals - 02 No | 1 | Each |
4 | Supply, installation in replacement, testing and commissioning of LT panel board (CPRI Approved) of suitable size factory made, compartment type, dust, water and vermin proof (IP-65 protection) duly powder coated with 7 tank process powder coating , outdoor type suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted fabricated out 3.15 mm thick CRCA Sheet on 50mm X 50mm X 6mm angle iron frame, 120 cm long angle iron legs 04 Nos for grouting in floor with cement concrete PCC foundation of suitable size in 1:2:4 and front & rear double door type inclusive of locking arrangement with provision of all incoming/outgoing cable entries along with suitable size of double compression type cable gland for incomming & out going cable all as specified and comprising the following:-a) LT bus bar aluminum TPN 300 Amps, 4 strips, duly sleeved with relevant colored insulation heavy duly mounted on epoxy insulators =1 Set Incomer : (b) MCCB AC, 4 pole, 200 Amps,25 KA, 50 Hz, 415 Volts with adjustable thermal & magnetic seting and Ics = 75 % of Icu = 01 No. Outgoing : (c ) MCCB AC, 4 pole, 100 Amps, 16 KA, 50 Hz, 415 Volts with adjustable thermal & magnetic seting = 01 Nos. (e) MCCB AC, 4 pole, 63 Amps, 16 KA, 50 Hz, 415 Volts with adjustable thermal & magnetic seting = 03 Nos. ( (2W + 1 (S) ) (f) Digital Amps meter 96x96 mm flush mounting type 0-200 amps range with CT s 200/5 A and selector switch= 01 Set. (g) Digital Voltmeter 96x96 mm flush mounting type 0-500 volts with selector switch =1Set. (j) Phase indicator lamps RYB =01 Set (k) Internal connections with colour code copper cable multistranded of suitable size copper thimbles etc as per manufacturers design and specfification incl SP MCB for each circuit (l) Danger notice plate 440 V with conventional skull and bones in red signal colour - 01 No and earthing terminals 02 nos. | 1 | Each |
5 | Supply, installation in replacement, testing and commissioning of LT panel board (CPRI Approved) of suitable size factory made, compartment type, dust, water and vermin proof (IP-65 protection) duly powder coated with 7 tank process powder coating , outdoor type suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted fabricated out 3.15 mm thick CRCA Sheet on 50mm X 50mm X 6mm angle iron frame, 120 cm long angle iron legs 04 Nos for grouting in floor with cement concrete PCC foundation of suitable size in 1:2:4 and front & rear double door type inclusive of locking arrangement with provision of all incoming/outgoing cable entries along with suitable size of double compression type cable gland for incomming & out going cable all as specified and comprising the following:- a) LT bus bar TPN aluminum 250 Amps, 4 strips, duly sleeved with relevant colored insulation heavy duly mounted on insulators =1 Set Incomer : (b) MCCB AC, 4 pole, 160 Amps,36 KA, 50 Hz, 415 Volts with adjustable thermal and magnetic release and Ics = 75% of Icu)= 01 No. Outgoing : (e) MCCB AC, 4 pole,32 to 63 Amps,25 KA, 50 Hz, 415 Volts with adjustable thermal and magnetic release= 03. (f) Digital Amps meter 96x96 mm flush mounting type 0-160 amps range with CT s 160/5 A and selector switch= 01 Set. (g) Digital Voltmeter 96x96 mm flush mounting type 0-500 volts with selector switch =1Set. (h) Phase indicator lamps RYB =01 Set (j) Internal connections with colour code copper cable multistranded of suitable size copper thimbles etc as per manufacturers design and specfification and protection MCB SP in each circuit. (k) Danger notice plate 440 V with conventional skull and bones in red signal colour - 01 No and earthing terminals 02 Nos (l) Spar space for mouting MCCB - 01 No | 1 | Each |