Installation Of On Line Water Quality Monitoring System With 5 Years Maintenance In 56 M.l.d Sewer Treatment Plant At Indirapuram, Ghaziabad
Documents
Unlock the opportunities
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
119000.00 -
Document Cost
4130.00 -
Estimated Cost
5950000.00
BOQ Items Total Items : 6 | Total Qty : 9
# | Item | Quantity | Units |
---|---|---|---|
1 | On Line BOD/COD/TSS/PH in-situ based Analyzer with panel for S.T.P Measurement items UV-VIS Spectrometry Double beam with entire spectrum scanning 200 720 nm wave lengths along with 256 unique pixel diode. MOC of BOD/COD/TSS sensor -Titanium 3.7 or better Cleaning facility.-ultrasonic cleaning Accuracy of BOD/COD/TSS sensor- +/-3% of the measured value Following measuring ranges are required as minimum: COD: 0-800 mg/l BOD: 0-500 mg/l TSS: 0-900 mg/l lPh range - 4 to 12 MOC of ph sensor-Stainless Steel or better protection type : IP 68 for both the Sensor and Cable Controller features- Housing Material Non corrosive e.g. Acrylonitrile-Styrene-Acryloester polymer or better Protection Rating IP 67 | 1 | NO |
2 | Data Logger (including Data transmission for Five years). The communication to the system should be two way The data should be received at a central location and should be displayed there in real-time in graphical and tabular format. Statistical data analysis (customizable) for average, min., max., diurnal variation. Auto report and, auto mail generation etc. Comparison of parameters of different locations in user selectable time formats i.e. in graphical and tabular formats compatible to MS Excel, MS Word, *.txt etc. Data logger provided should be approved by UP POLLUTION CONTROL BOARD. | 1 | NO |
3 | Open channel Ultrasonic flow meter. Make - FORBS MARSHAL/E & H/Siemens or Equivalent. Measuring Ranger- 0.25 m to 6 m. Sensor material- PVDF. Process conn-2" NPT. Cable inlet- 2x1/2" NPT. Ambient Temp- -40 to +80 C. Power supply- 24 to 30 VDC. Pressure- 0.5 bar. Output 4 to 20 mA, Protection-IP 67. Display-Integral LCD Display.Including all civil work required for Installation of on line water quality material. | 1 | NO |
4 | Optical based Dissolved oxygen analyzer. The sensor should be factory calibrated and ready to use in the field. Change of optical DO sensor membrane should not require any field calibration with data transfer. Measurement Range: 0.00 -20.00 mg/l DO or : 0-200% Saturation Response time: T90 Equivalent of less than 60 Seconds. Signal Output Digital Power Consumption: less than 1 Watt Temp Compensation: -5 to +50 Deg C MOC of do sensor -316 Ti SS or better protection type : IP 68 the Sensor and Cable & Integrated lightning protection | 4 | NO |
5 | Ammonical Nitrogen (NH4-N) Analyzer Measuring principle-ion Selective Material: Electrode connector and protective hood: POMEnclosure shaft and temperature sensor: V4A stainless steel 1.4571Pressure resistance: Armature with installed electrodes: Max. 0.2 bar over pressure.protection type : IP 68 the Sensor and Cable & Integrated lightning protection.Measuring range-0.1 ...1000 mg/l NH4-N With data transfer | 1 | NO |