Tender for WEST BENGAL MEDICAL SERVICES CORPORATION LIMITED - NTID 29343859
WEST BENGAL MEDICAL SERVICES CORPORATION LIMITED
Murshidabad, West Bengal, India
NTID 29343859
- Opening Date : Tue 6th December, 2022
- Closing Date : Mon 5th December, 2022
- ₹ 0.00
- NTID 29343859
Establishment Of 24 Bedded Hybrid Critical Care Unit At Domkol Super Specialityhospitalhvac Work, Dist Murshidabad, 2nd Call
Documents
Unlock the opportunities
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
138541.00 -
Document Cost
Refer Documents -
Estimated Cost
Refer Documents
BOQ Items Total Items : 45 | Total Qty : 2842
# | Item | Quantity | Units |
---|---|---|---|
1 | Supplying, installing, testing and commissioning (including the charges for lifting, shifting, scaffolding & all other charges or accessories etc.) of Ceiling Mounted Ductable DX type Air Conditioning Unit having multiple Scroll compressor, 400V/3 PH/50 Hz Microprocessor based Controler of 16.5-17TR nominal capacity with R-410A or R-407C Refrigerant. (Make-Hitachi/Mitsubishi/O-General /Carrier/Voltas/Daikin). | 6 | Each |
2 | Supplying, installing, testing and commissioning (including the charges for lifting, shifting, scaffolding & all other charges or accessories etc.) of Ceiling Mounted Ductable DX type Air Conditioning Unit having multiple Scroll compressor, 400V/3 PH/50 Hz Microprocessor based Controler of 8-8.75TR nominal capacity with R-410A or R-407C Refrigerant. (Make-Hitachi/Mitsubishi/O-General /Carrier/Voltas/Daikin). | 1 | Each |
3 | Supplying, installing, testing and commissioning (including the charges for lifting, shifting, scaffolding & all other charges or accessories etc.) of Ceiling Mounted Concealed type Air Conditioning Unit with 36100 btu/hr Cooling capacity,650 CFM Air Flow Each IDU x 2 nos 1.5 TR/2 nos. 1.5TR Highwall Split 1:1, with 2 nos. Twin Rotary compressor, 230V/1 PH/50 Hz Microprocessor based Controller of 3.0 TR nominal capacity with R-410A or R-407C or R-32 Refrigerant..(Make-Hitachi/Mitsubishi/O-General /Carrier/Voltas/Daikin) | 2 | Each |
4 | Supplying, installing, testing and commissioning (including the charges for lifting, shifting, scaffolding & all other charges or accessories etc.) of Ceiling Mounted Concealed/ Highwall Split type Air Conditioning Unit with 24000 btu/hr Cooling capacity,850 CFM Air Flow1 nos IDU, with 1 nos. Twin Rotary compressor, 230V/1 PH/50 Hz Microprocessor based Controller of 2.0 TR nominal capacity with R-410A or R-407C or R-32 Refrigerant..(Make-Hitachi/Mitsubishi/O-General /Carrier/Voltas/Daikin) | 2 | Each |
5 | CABINET TYPE CENTRIFUGAL FAN FOR EXHAUST SYSTEM FOR CRITICAL AREA: Supplying, installing, testing and commissioning (including the charges for lifting, shifting, scaffolding & all other charges or accessories etc.) of factory built Floor Mounted double skin type Exhaust Units made of 25 2mm thick panels with plenum box made of thickness 0.6 mm GI outside and inside layer with polyurethane foam (PUF) insulation of density 40 2 kg/m3 factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward/backward curved centrifugal fan of static pressure mentioned below, Thermal Break profile, belt drive package with TEFC type VFD drive motor suitable for 415 10% volts, 50 Hz, 3 phase and canvass connection , necessary vibration isolation arrangement, complete as per specifications with suitable rating starter in IP--55 MS enclosure complete with suitable rating TP isolator in IP--55 MS enclosure near the units of following capacities: 3200 cfm, FM Type 85 mmwc SP (2W + 2S) (Make-Elta/Edgetech/VTS/Kruger/Marathon/Green Heck). | 6 | Each |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane