ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry Now
Corrigendum Repair maint Of , Jammu - Tender Details
Explore tender information for Corrigendum Repair maint Of in Jammu, including eligibility, deadlines, and bid specifics.
Military Engineer Services
Jammu, Jammu and Kashmir, India
NTID 38939956
Opening Date : Fri 14th February, 2025
Closing Date : Wed 12th February, 2025
- ₹ 3500000.00
- NTID 38939956
Corrigendum : Repair/maint Of Lt Panels,ups Stabilizers And Allied Works Under Age E/m Of Ge Satwari
Documents
Get Complete Tender Details Now – Download the Document!
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
70000.00 -
Document Cost
500.00 -
Estimated Cost
3500000.00
BOQ Items Total Items : 65 | Total Qty : 254
# | Item | Quantity | Units |
---|---|---|---|
1 | Supply, installation, testing & commissioning in replacement of totally enclosed feeder pillar, outdoor type, fabricated out of 3.15 mm thick CRCA sheet, dust and vermin proof, powder coated, double door type (independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed complete) suitable for operating on 415 Volts, 50 Hz, AC supply. internally wired with copper conductor, having legs 90 cms & made out of 50x50x6 mm angle iron grouted on brick masonary platform upto 45 cm. Brick masonary platform should be 60 cm above the ground Level. and comprising the following:- (a) Aluminium bus bar 400 Amps TPN of suitable length and of cross section as per design with colour codding. Bus bars shall be designed to with stand a fault level of 36 KA at 415 volts- 01 Set (b) MCCB 4 pole 250 Amp, 36 KA and thermal & magnetic releases with Ics=100%Icu. confirming to IEC 60947-2 with short circuit and over load protection. -01 No (Incoming) (c) MCCB 4 pole 100 Amp, 16 KA and thermal & magnetic releases with Ics=100%Icu. confirming to IEC 60947-2 with short circuit and over load protection. -03 Nos (Out going) (c) Change over switch 200A, 4 pole -01 No (d) MCB DP 32 Amp 240 Volts -01 No (Outgoing). (e) Digital type amp meter 0-500Amp with CT s & selector switch - 01 No (f) LED Indicating lamp (RYB-one set) (g) Digital voltmeter 0-500 volts with selector switch-01 No Note:- (i) The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii) Fabrication of feeder pillar box to be approved by CPRI, depth of the panel not less than 50 cm. (iii) Cost for construction of platform for panel of brick masonary work built in cement mortar 1:6 with foundation in 100mm thick PCC 1:4:8 type D-2 including plaster work in cement mortar 1:4 , 50mm thick coping in PCC 1:2:4 type B-1 deemed to be included in the item rate. No Extra payment will be made. (iv) MCCB's should be connected with extensions terminals at both side (incoming and outgoing) | 4.00 | Each Job |
2 | S&F totally enclosed bus bar feeder pillar, outdoor type, fabricated out of 3.15 mm thick CRCA sheet, dust and vermin proof, powder coated, double door type complete suitable for operating on 415 Volts, 50 Hz, AC supply, having legs 90 cm and made out of 50x50x6 mm angle iron grouted on brick masonary platform upto 45 cm. Brick masonary platform should be 60 cm above the ground level and comprising the following:- (a) Aluminium bus bar 500 Amps TPN of length suitable for fixing minimum 6 cables and of crossection as per design with colour codding. Bus bars shall be designed to with stand a fault level of 36 KA at 415 volts-01 Set (b) Digital type amp meter 0-500Amp with CT s & selector switch - 01 No. (c) LED Indicating lamp (RYB-one set) -01 No (d) Digital voltmeter 0-500 volts with selector switch-01 No Note:- (i) The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii) Fabrication of feeder pillar box to be approved by CPRI, width of the panel not less than 30 cm. (iii) Cost for construction of platform for panel of brick masonary work built in cement mortar 1:6 with foundation in 100mm thick PCC 1:4:8 type D-2 including plaster work in cement mortar 1:4 , 50mm thick coping in PCC 1:2:4 type B-1 deemed to be included in the item rate. No Extra payment will be made. (iv) After fixing the bus bar panel, all electric connections will be made without any extra cost all as specified and directed. | 7.00 | Each Job |
3 | Supply, installation, testing & commissioning in replacement of totally enclosed bus bar panel, outdoor type, fabricated out of 3.15 mm thick CRCA sheet, dust and vermin proof ,powder coated, double door type (independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed complete) suitable for operating on 415 Volts, 50 Hz, AC supply internally wired with copper conductor having legs 90 cm & made out of 50x50x6 mm angle iron grouted on brick masonary platform upto 45 cm. Brick masonary platform should be 60 cms above the ground level and comprising the following:- (a) Aluminium bus bar 160 Amps TPN of length suitable for fixing minimum 6 cables and of crossection as per design with colour codding. Bus bars shall be designed to with stand a fault level of 36 KA at 415 volts-01 Set (b) MCCB 630 Amp,4 pole, 36 KA having thermal & magnetic releases with Ics=100%Icu. conferming to IEC 60947-2 with short circuit and over load protection. (as incoming) -01 No (c) MCCB 250 Amp,4 pole,25 KA having thermal & magnetic releases with Ics=100%Icu. confirming to IEC 60947-2 with short circuit and over load protection (as incoming and outgoing) -02 Nos (d) MCCB 100 Amp, 4 pole ,16 KA having thermal & magnetic releases with Ics=100%Icu. conferming to IEC 60947-2 with short circuit and over load protection.(as incoming and outgoing) -02 Nos (e) MCCB 63 Amp,4 pole, 16 KA having thermal and magnetic releases with Ics=100%Icu. conferming to IEC 60947-2 with short circuit and over load protection.(as incoming and outgoing) -01 No (f) Digital type amp meter 0-500Amp with CT s & selector switch - 01 No. (g) LED Indicating lamp (RYB-one set) (h) Digital voltmeter 0-500 volts with selector switch -01 No Note:- (i) The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii) Fabrication of feeder pillar box to be approved by CPRI depth of the panel not less than 50 cms. (iii) Cost for construction of platform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate), deemed to be included in the item rate. No Extra payment will be made. (iv) MCCB's should be connected with extensions terminals at both side (incoming and outgoing). | 4.00 | Each Job |
4 | Taking out broken hinges/unserviceable hinges & door handles from feeder pillar/LT Panel and replace the same with mild steel hinges cold rolled of same size through spot welding & Mild steel sliding door bolt of same size including making necessary adjustment for free and smooth movement of panel and spray painting two coats of powder coating inside & outside the panel complete all as specified and directed. | 10.00 | Each Job |
5 | Taking out the damaged/deshaped part/portion of the LT Panel/feeder pillar and repalce the same with new portion made out of CRCA sheet 3mm thick including making necessary adjustment and allignment to make the existing feeder pillar/LT Panel to its required shape and size including spray painting two coats of powder coating inside & outside the panel complete all as specified and directed | 10.00 | Each Job |