ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowCorrigendum Provn Of Stand B, Kalaikunda - Tender Details
Explore tender information for Corrigendum Provn Of Stand B in Kalaikunda, including eligibility, deadlines, and bid specifics.
Military Engineer Services
Kalaikunda, West Bengal, India
NTID 38609596
- Opening Date : Tue 28th January, 2025
- Closing Date : Sun 26th January, 2025
- ₹ 4475000.00
- NTID 38609596
Corrigendum : Provn Of Stand By Power Supply At Sgr, Certain Entry Gates / Watch Towers And Provn Of Deficient Street Lights At Af Stn Salua Under Ge (af) Kalaikunda
Documents
Get Complete Tender Details Now – Download the Document!
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
89500.00 -
Document Cost
500.00 -
Estimated Cost
4475000.00
BOQ Items Total Items : 26 | Total Qty : 3663
# | Item | Quantity | Units |
---|---|---|---|
1 | Supply, installation, testing and commissioning of silent Diesel Engine driven generating set of 50 KVA, 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with 12 volt self starter arrangenment G3 class governor 'TA' nature of aspiration T.C having dry type Air filter diesel coupled with alternator having 0.8 power factor, 50Hz, 6 cylinder, with both engine and alternator mounted on the same base copmplete with fuel tank, residential silencer, AVM pads initial fill of engine oil & microprocessor based genset controller, with AMF Panel, relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms with db<75 and foundation etc. complete all as specified and directed | 1.00 | Each Job |
2 | All as per item no 1.00 above, but of capacity 20 KVA | 2.00 | Each Job |
3 | S&F, Installation , Testing and commissioning of LT control panel outdoor type of size 1.0x0.75x0.4 m having provision of double door openings into two halves with rubber beadings cubical type of suitable size as directed by the manufacturer, made out of 3.15 mm CRCA sheet compartmentalized with rubber beadings, angle iron 40 x 40 x 5 mm shall be used for making legs/ frame, duly powder coated internally and externally, including provn of Copper Busbar 400 Amps, Bus Bar chamber shall be provided with inspection covers, bottom cover shall have provision for fixing and including suitable cable glands of required size and specification for LT Cable entry, each MCCB, Change over, Bus Bar chambers, measuring instruments, etc including prewired shall have independent openings including provn of PCC Platform of suitable size PCC 1:2:4 all as directed by the Engineer-in-charge. The LT Panel comprising of the following:- 1). Incoming - MCCB 4 pole 415 Volts adjustable thermal & fixed magnetic setting Ics=100% Icu type of capacity 250 Amps, 36 KA breaking capacity - 01 No 2). Outgoing - MCCB 4 pole 415 Volts adjustable thermal & fixed magnetic setting Ics=100% Icu type of capacity 200 Amps, 16 KA breaking capacity - 01 No 3). Outgoing - MCCB 4 pole 415 Volts adjustable thermal & fixed magnetic setting Ics=100% Icu type of capacity 100 Amps, 16 KA breaking capacity - 02 No 4). VIF Digital meter with Suitable CTs for Ampere and Voltage display 5). LED Indicator lamp set of three colour 6). On load change over switch 250 A - 01 No Note : The rate quoted shall include disconnection of all existing Electrtical connections and reconnecting with the new panel with new Thimbles and nut bolts, wahsers, etc. and taking out old U/S panels as directed by the Engineer in charge. | 2.00 | Each |
4 | All as per the above item No 3.00 but The LT Panel comprising of the following:- 1). Incoming - MCCB 4 pole 415 Volts adjustable thermal & fixed magnetic setting Ics=100% Icu type of capacity 250 Amps, 36 KA breaking capacity - 01 No 2). Outgoing - MCCB 4 pole 415 Volts adjustable thermal & fixed magnetic setting Ics=100% Icu type of capacity 200 Amps, 16 KA breaking capacity - 01 No 3). Outgoing - MCCB 4 pole 415 Volts adjustable thermal & fixed magnetic setting Ics=100% Icu type of capacity 100 Amps, 16 KA breaking capacity - 02 No 4). Outgoing - MCCB 4 pole 415 Volts adjustable thermal & fixed magnetic setting Ics=100% Icu type of capacity 63 Amps, 16 KA breaking capacity - 02 No 5). VIF Digital meter with Suitable CTs for Ampere and Voltage display 6). LED Indicator lamp set of three colour 7). On load change over switch 250 A - 01 No Note : The rate quoted shall include disconnection of all existing Electrtical connections and reconnecting with the new panel with new Thimbles and nut bolts, wahsers, etc. and taking out old U/S panels as directed. | 1.00 | Each |
5 | S&F of Onload Change over Switch 125 A with complete enclosure and double door opening and closing arrangement for maintenance and suitable handle and fixture for operation purpose complete all as specified and directed. | 2.00 | Each |