NTID 43941873
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowWork Under R Andi For Replacem in Margao - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Work Under R Andi For Replacem" in Margao, India.
- Opening Date : Fri 20th February, 2026
- Closing Date : Thu 19th February, 2026
- ₹ 56544370.00
- NTID 43941873
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
1130887.00 -
Document Cost
1500.00 -
Estimated Cost
56544370.00
BOQ Items Total Items : 5 | Total Qty : 267
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | COST OF MATERIAL | ||
| 2 | Supply of 3 way RMU,11KV, 630A ,21KA 3Sec,SF6 outdoor RMU 2LB's + 1CB Extensible /Non extensible Two(2) Motor operated load break switch (LB'S)with Manual operated earthing switches in SF6 and one(1) Vacuum Circuit breaker with electrical closing & tripping along with disconnector and earthing switch SCADA compatible and bare channel.Battery charger along with batteries required for electrical operations of RMU is in the scope of the Bidder.Each module shall consists of VPIS, FPI in LBS module (N-I) but not less than 1 No's per RMU. Suitable arrangement for mounting FRTU,Modem or Ethernet Switch /LIU along with battery,battery charger shall be provided in RMU.(The new RMU should retrofit the existing RMU plinth and Cable) | 89.00 | Nos |
| 3 | COST OF LABOUR | ||
| 4 | Erection of 3 way RMU,11KV, 630A ,21KA 3Sec,SF6 outdoor RMU 2LB's + 1CB Extensible /Non extensible Two(2) Motor operated load break switch (LB'S)with Manual operated earthing switches in SF6 and one(1) Vacuum Circuit breaker with electrical closing & tripping along with disconnector and earthing switch SCADA compatible and bare channel.Battery charger along with batteries required for electrical operations of RMU is in the scope of the Bidder.Each module shall consists of VPIS, FPI in LBS module (N-I) but not less than 1 No's per RMU. Suitable arrangement for mounting FRTU,Modem or Ethernet Switch /LIU along with battery,battery charger shall be provided in RMU.(The new RMU should retrofit the existing RMU plinth and Cable) | 89.00 | Nos |
| 5 | Removal of 3 way RMU,11KV, 630A ,21KA 3Sec,SF6 outdoor Ring main units | 89.00 | Nos |