Inquiry NowSupply Installation And Comm in Dehradune - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Supply Installation And Comm" in Dehradune, India.
Centre For Aromatic Plants
Dehradune, Uttarakhand, India
NTID 43149022
- Opening Date : Tue 13th January, 2026
- Closing Date : Mon 12th January, 2026
- ₹ 0.00
- NTID 43149022
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
4025000.00 -
Document Cost
11800.00 -
Estimated Cost
Refer Documents
BOQ Items Total Items : 4 | Total Qty : 3
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | TECHNICAL SPECIFICATION OF ACCELERATOR MASS SPECTROMETRY (AMS) The AMS system should be complete in all respects, fully automated including all hardware, software, control systems, data acquisition, data analysis, with hardware and software interlocks etc. to measure 12C, 13C, 14C for determining the biobased content of solid and liquid samples using radiocarbon analysis as per ASTM D6866-24, EN 16640, ISO 13833 methods. The equipment should measure carbon isotopes (12C, 13C, 14C) in graphitized samples and the detailed specification as follows: | ||
| 2 | A-SAMPLE PREPARATION SYSTEM Graphitization System The automated graphitization equipment should be provided to graphitize the CO2 gas samples in a fully automated way. It should include oven, cooler, transducer, Sample reactor/holder, Inlet port and traps etc with following specifications- a) Total mass: range from 25 g to 500 mg or better b) Carbon content: range from 25 to 5000 g C c) Carbon concentration: 0.03% to 100% d) Process blank over AMS: should be less than 0.002 fM e) Sample cross-talk: < 1 / mg C | 1.00 | Nos |
| 3 | B-AMS SYSTEM AMS System should include four major parts i.e. Ion Source/ Injector System, Low energy magnet/ spectrometer/ injector & magnet, Accelerator and High Energy Mass Spectrometer/ High Energy Magnet. The summarised specification are as follows: 1) Ion Source/ Injector System Type of Ion Source: Multiple cathode negative ion source: a) Injection voltage / energy: maximum 100 kV, b) Ion current (12C- low energy): maximum 100 A, c) Number of samples: Minimum 40 samples (continuous measurement) 2) Low Energy Magnet/ Spectrometer/ Injector & Magnet a) Magnet type: Electromagnet, b) Types of isotopes measured: 12C/ 13C/ 14C, c) Type of Faraday cups: Offset/others, d) Necessary vacuum system/pump with base pressure less than or equal to 5 x 10-7 torr. 3) Accelerator a) Type: single ended accelerator, b) Terminal voltage: range 200-300 kV, c) Voltage generation: Solid state power supply d) Terminal gas stripper, if any: Nitrogen/ Argon 4) High Energy Mass Spectrometer / High Energy Magnet a) Magnet type: Electromagnet, b) Faraday cups for 12C & 13C , c) Electric field: Electrostatic analyser (ESA), d) 12C Beam transmission: 40% or more, e) 14C detection system: I. Detector System- solid state detector and gas state detector a) Precision for 1 mg graphite with a modern reference material, II. 14C/12C: 0.2% or less, III. 13C/12C: 0.2% or less, IV. Background for 14C/ 12C of a processed blank sample: 2 10-15 or less. | 1.00 | Nos |
| 4 | C- OPERATION, SOFTWARE, COMPUTER AND DATA MANAGEMENT 1) In view of the presentation made by member secretary, the committee recommended to go for option of single ended accelerator as it suits the proposed application and there will be no compromise to generate quality data. Also the operation and maintenance of single ended accelerator is easier compared to complex tandem accelerators. Moreover, it requires less area to accommodate with essential accessories. 2) All the features of the data station such as operating system, controller software, hard disk storage capacity, memory, printer(s) etc. should be provided. 3) The system should be fully automated for control and sample measurements and party should provide data base server to systematically manage the result of samples. 4) Automation system to enable personnel for fast work and efficient time utilization by intervening only at the sample loading and analysis stages. 5) Operation should be user-friendly, easy to use and prevent mistake with intuitive structure. 6) The original licensed software(s) with respect to operating system, control system, processing software, data management system, reporting AMS results and other accessories should be provided along with the AMS system, and all should have the validity for the entire life cycle of the AMS system. 7) Upgraded software compatible with original licensed software provided with the AMS system will be provided free of cost by the bidder for the entire life cycle of the AMS system | 1.00 | Nos |