- Home
- >
- Tender
- >
- Rajasthan Tender
- >
- Department of JAIPUR DEVELOPMENT AUTHORITY
- >
NTID 47276867
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowShifting And Dismantling Of Lt in Jaipur - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Shifting And Dismantling Of Lt" in Jaipur, India.
- Opening Date : Wed 25th November, 2026
- Closing Date : Wed 18th November, 2026
- ₹ 179428000.00
- NTID 47276867
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
3588560.00 -
Document Cost
2500.00 -
Estimated Cost
179428000.00
BOQ Items Total Items : 90 | Total Qty : 143572
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 33 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | ||
| 2 | 3 core 300.0 Sq.mm | 9800 | Mtr |
| 3 | Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit suitable for 11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streight through joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Cross linking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. including testing etc. as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | ||
| 4 | 33 KV End Termination Kit Outdoor type, 3 core 240/300/400 Sq.mm | 20 | Each |
| 5 | 33 KV Straight Through Joint Kit , 3 core 185/240/300 Sq.mm | 50 | Each |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054