- Home
- >
- Tender
- >
- Kerala Tender
- >
- Department of Regional Cancer Centre
- >
NTID 46065832
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowReplacement Of Damaged Nrvs An in Thiruvananthapuram - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Replacement Of Damaged Nrvs An" in Thiruvananthapuram, India.
Regional Cancer Centre
Thiruvananthapuram, Kerala, India
NTID 46065832
- Opening Date : Tue 11th August, 2026
- Closing Date : Mon 10th August, 2026
- ₹ 408765.00
- NTID 46065832
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
BOQ Items Total Items : 6 | Total Qty : 19
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Non-Return Valves | ||
| 2 | Replacement of damaged 200 mm Non-Return Valves in condenser pumps. Scope includes: careful removal of existing damaged NRVs and disconnection from pipeline, necessary welding, grinding, fitting and alignment works for new NRV installation, supply and fixing of new 200 mm ductile iron PN 16 NRV (dual plate/swing check type, approved make), followed by hydrostatic testing at 1.5 times working pressure, leak rectification if required, commissioning, debris disposal, and site reinstatement, all as per Kerala PWD specifications, relevant IS codes, and Engineerin- Charge directions. - 200 mm dia | 3 | Nos |
| 3 | Replacement of damaged 150 mm Non-Return Valves (NRVs) in primary and secondary pumps. Scope includes: careful removal of existing damaged NRVs and disconnection from pipeline, selective removal of insulation and cladding limited to the NRV area, necessary welding, grinding, fitting and alignment works for new NRV installation, supply and fixing of new 150 mm ductile iron PN 16 NRV (dual plate/swing check type, approved make), application of 50 mm minimum thick PUF insulation and 0.63 mm aluminium cladding over the valve and adjacent limited area, followed by hydrostatic testing at 1.5 times working pressure, leak rectification if required, commissioning, debris disposal, and site reinstatement, all as per Kerala PWD specifications, relevant IS codes, and Engineer-in Charge directions. - 150 mm dia | 8 | Nos |
| 4 | Non-Return Valves | ||
| 5 | Replacement of damaged rubber expansion elbows (rubber bellows/expansion joints) in primary and secondary pumps for chilled water system. Scope includes: careful removal of existing damaged rubber bellows (minimum PN 16 rating, capable of absorbing vibrations, noise, shock, etc.), disconnection from pipeline flanges, necessary welding, grinding, fitting, alignment and any minor rectification works for new installation, supply and fixing of new rubber expansion joint/bellow (EPDM/Neoprene, single/double sphere, flanged ends, PN 16 rating, suitable for chilled water, approved make), followed by hydrostatic testing at 1.5 times working pressure, leak rectification if required, commissioning, debris disposal, and site reinstatement, all as per Kerala PWD specifications, relevant IS codes, and Engineer-in-Charge directions. - 150 mm dia | 2 | Nos |