- Home
- >
- Tender
- >
- Odisha Tender
- >
- Department of DEFENCE RESEARCH AND DEVELOPMENT ORGANISATION
- >
NTID 45187992
ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowReplacement Of 02 Nos Of 120 T in Bansada-O - Complete Tender Details
Find eligibility criteria, important deadlines, bidding requirements, and download official documents for "Replacement Of 02 Nos Of 120 T" in Bansada-O, India.
- Opening Date : Tue 26th May, 2026
- Closing Date : Mon 25th May, 2026
- ₹ 5205031.00
- NTID 45187992
Tender Description
Documents
Get Complete Tender Details Now - Download the Document!
Download Now – Only ₹200-
Document-1
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
Document-2
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
104101.00 -
Document Cost
Refer Documents -
Estimated Cost
5205031.00
BOQ Items Total Items : 1 | Total Qty : 2
| # | Item | Quantity | Units |
|---|---|---|---|
| 1 | Supply, installation, testing and commissioning of 02 Nos of 120 TR floor-mounted AHRI (Air Conditioning, Heating, and Refrigeration Institute) Certified water cooled screw-type chiller machine complete with VFD (Variable Frequency Drive), single/multi semi-hermatic twin screw type compressor, water-cooled Shell & Tube type condenser, Shell & Tube horizontal flooded type evaporator with carbon steel shell and seamless copper tubes with 19 mm nitrile rubber insulation i/c suitable foundation/mounting structure made of RCC/MS Structure i/c anticorrosive paint, anti vibration pad, power control cable and connection inter connection etc. as per design approved by engineer-in charge, interconnected copper refrigerant piping and wiring, vibration Isolators, gauge panel, automatic safety controls, flow switch at evaporator and condenser and ozone friendly Chlorofluorocarbons (CFC)-free refrigerant gas R-134A. The refrigerant flow control shall use an electronic expansion valve. The chiller shall be designed for a Water Side working pressure of 150 PSI and hydraulically tested at 1.3 times of design pressure. A number of properly spaced baffles shall be provided for maintaining optimum water velocity and heat transfer and the tubes shall be adequately supported. The chiller shall be Building Management System (BMS) compatible The system shall be in confirmation to IS : 16590 and CPWD Specification as amended upto date. Chilled water Leaving Temp. (6.67 deg. C) Chilled water Entering Temp. (12.2 deg. C) Evaporator fouling factor = 0.018 m2. C/kW Condenser water Entering Temp. (32.2 deg. C) Condenser water Leaving Temp. (36.4 deg. C) Suitable for Seismic Zone and Altitude as per location/site. All complete or as directed by Project Manager / Engineer-In-Charge. (Make : Hitachi / Carrier / Blue Star / Voltas). | 2 | Nos |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054